Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE REVIEW v.3
Permit Number - TD-DEV-1222-00088
Review Name: DEVELOPMENT PACKAGE REVIEW v.3
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/20/2023 | Site Engineering | APPROVED | Waiting on TSMR review | ||
06/16/2023 | TSMR/PDMR - Zoning | APPROVED | |||
07/24/2023 | Zoning Modifications - DDO | APPROVED | |||
07/24/2023 | CDRC Post Review | PENDING ASSIGNMENT | |||
06/21/2023 | Site Zoning | REQUIRES RESUBMIT | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Wyatt Berger Lead Planner PROJECT: 116 N Cherry Ave Development Package (3rd Review) TD-DEV-1222-00088 TRANSMITTAL DATE: June 21, 2023 DUE DATE: June 17, 2023 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC), Administrative Manual (AM) Section 2-06, and with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Per UDC Section 3.3.3.G.5.c, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year expiration date is June 21, 2023. 4.7 General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 1. COMMENT: 2-06.4.7.A.6.a – If the submitted DDO request is approved, provide the DDO case number to the title block within the lower right corner of each sheet. 2. COMMENT: 2-06.4.9.H.5 – Per UDC Table 7.4.6-2, the minimum width of a two-way access lane (PAAL) is 20 feet. Ensure that the access lane meets this requirement. 4. COMMENT: 2-06.4.9.O – The required front street setback is 20 feet, measured from the street property line (UDC 6.4.5.C.1.a). Based on a wall height of 9 feet, the required front street setback is 20 feet; proposed is 18 feet. Design Development Option (DDO) approval is required to reduce this setback. 5. COMMENT: 2-06.4.9.O – Per UDC Table 6.3-2.A, when a nonresidential use is adjacent to a residential zone, the required interior setbacks are 10 feet, or ¾ the height of the proposed wall, whichever is greater. Based on a wall height of 20 feet, the required setback measured from the south lot line is 15 feet; proposed appears to be 13’-9”. Additionally, based on a wall height of 9 feet, the required setback measured from the south lot line is 10 feet; proposed is 5’-2”. Design Development Option (DDO) approval is also required to reduce these setbacks. If you have any questions about this transmittal, please contact me at Wyatt.Berger@tucsonaz.gov or at (520) 837-4951. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
||
05/18/2023 | CDRC Application Completeness | REVIEW COMPLETED | |||
06/06/2023 | TSMR/PDMR - Engineering | REVIEW COMPLETED |