Permit Number: TD-DEV-1222-00074
Parcel: 116210220

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE REVIEW v.1

Permit Number - TD-DEV-1222-00074
Review Name: DEVELOPMENT PACKAGE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/27/2023 Commercial Plumbing APPROVED
11/22/2023 NPPO APPROVED
11/29/2023 Site Engineering APPROVED
11/22/2023 Site Landscape APPROVED
11/22/2023 Site Zoning APPROVED Please be aware that a Liquor Mitigation Plan in accordance with UDC 4.9.4.V.9 is required for this project. Contact Heather.Thrall@tucsonaz.gov should you have questions regarding this process.
11/29/2023 CDRC Post Review Express PENDING ASSIGNMENT
11/16/2023 ROW Engineering Review REQUIRES RESUBMIT TD-DEV-1222-00074
1000 W. Congress St.

Comments:
1. Any existing curb, sidewalk or curb access ramps which are not compliant with current standards will be modified or replaced to meet current standards.
2. Westerly most “existing” driveway apron on Congress to be replaced to meet current standards, per P.A.G. standard 206.
3. The closing of the easterly most driveway apron on Congress will require a Meter Box adjustment.
4. Existing curb access ramp on the SW corner of Congress St and Grande Ave. is to be replaced to meet current standards per P.A.G. standard 207.
5. The closing of the northerly most driveway apron on Grande Ave will require a Manhole adjustment.
6. The southernly most driveway apron on Grande Ave is to be replaced to meet current standards per P.A.G. standard 206.
7. The existing sidewalk approaching the alley on the southeast corner of the property, is to be replaced to meet current standards per P.A.G. standard 200.
8. Concrete curb per P.A.G. standard 209.
9. At least one sidewalk is required to connect the onsite circulation path to sidewalk in the ROW.
10. Where adjoining sidewalk from the property ties to sidewalk along the ROW frontage, a 5’ X 5’ ADA landing is required. Landings shall be 5’ X 5’ and not to exceed a 2% cross slope in all directions.
11. Protect in place existing streetlights.
12. Protect in place existing catch basins.
13. Protect in place or relocate accordingly, existing regulatory or warning signs.

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
10/25/2023 CDRC Application Completeness Express REVIEW COMPLETED
11/03/2023 CDRC Review Coordinator Express REVIEW COMPLETED External Reviewers not required. No further action is required from customer at this time.
11/29/2023 Fire New Construction REVIEW COMPLETED
10/27/2023 OK to Submit - Engineering Fast REVIEW COMPLETED
10/27/2023 OK to Submit - Landscape Fast REVIEW COMPLETED
10/27/2023 OK to Submit - Zoning Fast REVIEW COMPLETED