| 07/01/2026 | Site Engineering Standard | APPROVED | |||
| 06/30/2026 | Site Zoning Standard | APPROVED | |||
| 07/20/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | The junction of the building drain and the building sewer is defined as being 30 inches from the exterior wall of the building. RWRD Detail 401 specifies the installation of a cleanout 12 inches from the beginning of the public right of way. The Utility Plan, C3.0, only shows one cleanout. [Previous comment: Provide a cleanout at the junction of the building drain and the building sewer, and a cleanout in the building sewer prior to entering the right-of-way on Sheet C3.0. Currently, only one 4” sewer cleanout is shown. Reference: Section 708.1.3, IPC 2018 & Pima County Standard Detail RWRD 401, 2021.] If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov |