Permit Number: TD-DEV-1123-00463
Parcel: 116192320

Address:
310 W ALAMEDA ST

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-1123-00463
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/30/2023 Commercial Plumbing APPROVED Master plan set is located under TD-DEV-1123-00455 / Studio session 530-328-308.
11/29/2023 NPPO APPROVED Master plan set is located under TD-DEV-1123-00455 / Studio session 530-328-308.
12/08/2023 Site Engineering APPROVED Master plan set is located under TD-DEV-1123-00455 / Studio session 530-328-308.
12/08/2023 CDRC Post Review PENDING ASSIGNMENT
12/04/2023 Historic REQUIRES RESUBMIT Project is located within the El Presidio Historic Preservation Zone and requires review and approval by the El Presidio Historic Zone Advisory Board and the Plans Review Subcommittee. Please resubmit plans with information on materials, attachments, etc. under the Historic sub-record.
12/04/2023 Site Landscape REQUIRES RESUBMIT Master plan set is located under TD-DEV-1123-00455 / Studio session 530-328-308.
11/29/2023 Site Zoning REQUIRES RESUBMIT Master plan set is located under TD-DEV-1123-00455 / Studio session 530-328-308.CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: 310 W ALAMEDA ST
Development Package (1st Review)
TD-DEV-1123-00463

TRANSMITTAL DATE: November 29, 2023



COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is November 17, 2024 .

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)



2-06.3.12 - An index of sheets in the development package shall be provided on the first sheet.

1. COMMENT: 2-06.3.12 - Please provide a index as noted by the standard above.


CONTENT REQUIREMENTS

2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. The applicable registration or license number shall be provided if prepared by or with the assistance of a registered professional, such as a surveyor, architect, landscape architect, or engineer. All sealing shall be consistent with Arizona Board of Technical Registration guidelines.

2. COMMENT: 2-06.4.1 - Provide information noted by the standard above for all person that prepared the development package as noted by the standard above.


2-06.4.2 - The title block shall include the following information and be provided on each sheet:


2-06.4.2.B - A brief legal description

3. COMMENT: 2-06.4.2.B - On the title block provide a brief legal description.



2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx).

4. COMMENT: 2-06.4.2.D - Provide the information noted by the standard above.


2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet.

5. COMMENT: 2-06.4.3 - Provide the development package case number,TD-DEV-1123-00455 , adjacent to the title block on each sheet.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

Zoning and Land Use Notes



2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses.

6. COMMENT: 2-06.4.7.A.4 - Provide a note that states “ No change to the existing use”




2-06.4.7.A.6.a - List additional applications and overlays, by case number (if applicable), in lower right corner of each sheet. As a general note provide the type of application processed or overlays applicable, a statement that the project meets the criteria/conditions of the additional application or overlay, the case number, date of approval, what was approved, and the conditions of approval, if any.

COMMENT: 2-06.4.7.A.6.a - These sites are located in the historic zone (UDC 4.7.9). Historic Review is required. Zoning can not approve this Development package until the historic review has been approved.

- As the project is within the Rio Nuevo District (RND) review by the Design Review Board (DRB) is required. Provide the RND case number adjacent to the title block on all sheets and provide a general note stating the case number, date of approval, and if applicable any conditions of approval on the plan. This review must be completed prior to approval of the development package.


2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.


2-06.4.8.B - All easements shall be drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated. Blanket easements should be listed in the notes, together with recordation data and their proposed status. Should an easement not be in use and be proposed for vacation or have been abandoned, so indicate. However, should the easement be in conflict with any proposed building location, vacation of the easement shall occur prior to approval of plan unless written permission from easement holder(s) is provided.

7. COMMENT: 2-06.4.8.B - If applicable provide the information noted by the standard above.

2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.

8. COMMENT: 2-06.4.8.C - Provide the information noted by the standard above for the right of way.


2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.







2-06.4.9.H.2 - Show future and existing sight visibility triangles. On a designated MS&R street, the sight visibility triangles are based on the MS&R cross-section.

9. COMMENT: 2-06.4.9.H.2 – Provide the information noted by the standard above for Major streets.





2-06.4.9.W - Indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Indicate if there are any existing billboards on site. Compliance to the Sign Code, Chapter 3 of the Tucson Code, is required.

10. COMMENT: 2-06.4.9.W - Provide a note on the cover sheet that states “ All proposed sign will be approved per a separate permit”


***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations




If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
11/22/2023 CDRC Application Completeness REVIEW COMPLETED Master plan set is located under TD-DEV-1123-00455 / Studio session 530-328-308.
11/28/2023 CDRC Review Coordinator REVIEW COMPLETED Master plan set is located under TD-DEV-1123-00455 / Studio session 530-328-308.
External Reviewers not required.
No further action is required from customer at this time.
12/01/2023 Fire New Construction REVIEW COMPLETED Master plan set is located under TD-DEV-1123-00455 / Studio session 530-328-308.
11/28/2023 OK to Submit - Engineering REVIEW COMPLETED Master plan set is located under TD-DEV-1123-00455 / Studio session 530-328-308.
11/22/2023 OK to Submit - Landscape REVIEW COMPLETED Master plan set is located under TD-DEV-1123-00455 / Studio session 530-328-308.
11/27/2023 OK to Submit - Zoning REVIEW COMPLETED Master plan set is located under TD-DEV-1123-00455 / Studio session 530-328-308.
12/06/2023 ROW Engineering Review REVIEW COMPLETED Master plan set is located under TD-DEV-1123-00455 / Studio session 530-328-308.