Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-1123-00457
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/22/2023 | Commercial Plumbing | APPROVED | |||
11/22/2023 | NPPO | APPROVED | |||
11/28/2023 | CDRC Post Review | PENDING ASSIGNMENT | |||
11/21/2023 | ROW Engineering Review | REQUIRES RESUBMIT | TD-DEV-1123-00457 1521 S. Chrysler Ave. Comments: 1. Keynote No. 1 Pg. 5 of Parkview Park Basin- Plan. Please provide a thorough detail of the “Modified” type 3 scupper. Or construct it per P.A.G. standard 205.5. 2. Keynote No. 2 Pg. 5 of Parkview Park Basin- Plan. Please provide a detail of the “Inlet Apron.” Vertical curb is necessary for type 3 scupper. Transition from wedge to vertical may be necessary. David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
||
11/28/2023 | Site Engineering | REQUIRES RESUBMIT | 1. A floodplain use permit will be required for work in and adjacent to Citation Wash. See instructions below. 2. Verify elevations on basin plan. Basin A appears to be 3.4’ deep with an additional 2’ sump. 3. Please provide PAG 105 in lieu of Post and Cable barrier. 4. Identify Enhanced Infiltration area per general note 4 on sheet 5. 5. Provide detail of dumped rip-rap & filter fabric – provide specification for filter fabric. 6. Provide documentation that the basins will sufficiently infiltrate within 24 hours. Joshua Garcia joshua.garcia@tucsonaz.gov This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TIs and solar). Construction of separate builds/new structures does not require a cost estimate to be provided. Construction of new buildings require elevation one foot above the base flood elevation, which may require that the foundation of the building be raised as much as two feet above the existing elevation onsite. Storage buildings with no utilities may be wet floodproofed using flood vents. For all new construction buildings, two elevation certificates must be filled out by a registered land surveyor and submitted to the City, one before the foundation is poured and one after construction is completed. Instructions: 1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record 2. Locations -> Confirm the location is accurate to the project. Click “Next” 3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next” 4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next” 5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next” 6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next” 7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next” 8. Review and Submit -> Review all information to ensure accuracy. Click “Submit” Contact Lianne Evans at lianne.evans@tucsonaz.gov or Stephen Blood at Stephen.Blood@tucsonaz.gov if you have any questions about the FUP. |
||
11/22/2023 | Site Landscape | REQUIRES RESUBMIT | COMMENTS: 1. Ensure all Zoning and Engineering comments are addressed prior to the Landscape/NPPO comments. 2. Include Case# (TD-DEV-1123-00457) on all sheets in the plan set. |
||
11/27/2023 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Joint RFCD – COT GSI Project Development Package (1st Review) TD-DEV-1123-00457 TRANSMITTAL DATE: November 27, 2023 DUE DATE: December 01, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is November 19, 2024. 2-06.4.0 CONTENT REQUIREMENTS 1. COMMENT: 2-06.4.3 – Provide the development package case number, TD-DEV-1123-00457, adjacent to the title block on all sheets. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2. COMMENT: 2-06.4.7.A.1 – Provide a general note stating “EXISTING ZONING IS R-1.” 3. COMMENT: 2-06.4.7.A.2 - Provide a general note listing the gross area of the site/subdivision by square footage and acreage. 4. COMMENT: 2-06.4.7.A.4 – Provide a general note that identifies the existing use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. The use should be “PARKS AND RECREATION SUBJECT TO USE SPECIFIC STANDARDS 4.9.13.B & C. If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package & detailed response letter. |
||
11/20/2023 | CDRC Application Completeness | REVIEW COMPLETED | No registrant stamp on plans. COT project. | ||
11/21/2023 | CDRC Review Coordinator | REVIEW COMPLETED | External Reviewers not required. No further action is required from customer at this time. |
||
11/21/2023 | Fire New Construction | REVIEW COMPLETED | |||
11/20/2023 | OK to Submit - Engineering | REVIEW COMPLETED | |||
11/20/2023 | OK to Submit - Landscape | REVIEW COMPLETED | |||
11/20/2023 | OK to Submit - Zoning | REVIEW COMPLETED |