Permit Number: TD-DEV-1122-00045
Parcel: 132191250

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE REVIEW v.1

Permit Number - TD-DEV-1122-00045
Review Name: DEVELOPMENT PACKAGE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/05/2023 Commercial Plumbing APPROVED
12/19/2022 Site Landscape APPROVED Note GC with plant symbol/riprap and r/w should be labeled both existing/future.
12/19/2022 NPPO NOT REQUIRED
12/08/2022 OK to Submit - External Reviewer PC Addressing NOT REQUIRED
01/05/2023 CDRC Post Review PENDING ASSIGNMENT
12/27/2022 Site Engineering REQUIRES RESUBMIT 1. Provide a demolition plan showing site features to be removed
2. Provide a waste stream calculation showing the planned waste meets the requirements of TSM 8-01.8
3. Provide a detail for the water harvesting areas showing the 6-9" minimum depression from top of ground to ground cover. Also show 2" minimum ground cover
4. Site plan calls out 6" vertical curb, but grading plan does not show a difference between curb height and pavement height in some places (for example, at the pedestrian path to the waste enclosure). Please clarify
5. Show on the parking detail how the 4' pedestrian circulation is maintained with a 2.5' vehicle overhang from the wheel stop. (TSM 7-01)
6. Correct the keynote for the ramp on the right side of the southern pedestrian circulation crossing to note 19
Scott Haseman
scott.haseman@tucsonaz.gov
12/22/2022 Site Zoning REQUIRES RESUBMIT CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: 4801 S CAMPBELL AV
Development Package (1st Review)
TD-DEV-1122-00045
TRANSMITTAL DATE: December 22, 2022



COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is November 17 , 2023 .

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)


2-06.3.0 FORMAT REQUIREMENTS



2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet.

1. COMMENT: 2-06.4.3 - Provide the development package case number, TD-DEV-1122-00045 , adjacent to the title block on each sheet.



2-06.4.4.B - Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property; and,

2. COMMENT: 2-06.4.4.B - Label Benson HY on the location map


2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.



2-06.4.9.H.5 - If utilizing parking area access lanes (PAALs), they shall be designed in accordance with Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

3. COMMENT: 2-06.4.9.H.5 - Provide a detail for the backup spur per UDC section 7.4.6.F.4.C " A minimum distance of three (feet must be provided between the back of spur and any wall, screen , or other obstruction over six inches in height”


2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

4. COMMENT: 2-06.4.9.H.5.a - Clarify if the ADA parking proposed for is site is Van-accessible, on the site the width of the ADA space is 9ft but on the detail its show a width of 8ft.
5. Provide a detail for the wheel stops per UDC section 7.4.6.H.1
6. Provide dimension for the stacking detail, stacking spaces must be a minimum of nine feet in width and 18 feet in length.




2-06.4.9.H.5.d - Show bicycle parking facilities fully dimensioned. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Provide, as a note, calculations for short and long term bicycle spaces required and provided.

7. COMMENT: 2-06.4.9.H.5.d - Per UDC Section 7.4.9.C.2.a “short term bicycle parking must be within 50 feet of each public entrance to a building as measured along the most direct pedestrian access route”




2-06.4.9.J - If street dedication is not required or proposed and the project site is adjacent to a Major Street or Route, draw the Major Street right-of-way lines for those streets. (Add the MS&R future sidewalk, right-of-way lines, sight visibility triangles, etc.)

8. COMMENT: 2-06.4.9.J - Show the future sidewalk




2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s).

9. COMMENT: 2-06.4.9.Q - Provide the use as noted by the standard above




2-06.4.9.T - Show refuse collection areas, including locations of dumpsters, screening location and materials, and vehicle maneuverability, fully dimensioned, and access route. If dumpster service is not proposed, indicate type of service. For specific information on refuse collection, refer to Section 8-01.0.0, Solid Waste and Recycle Disposal, Collection, and Storage, of the Technical Standards Manual. Refuse collection on all projects shall be designed based on that section, even if collection is to be contracted to a private firm.

10. COMMENT: 2-06.4.9.T – Provide the information noted by the standard above.



***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations



If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
12/01/2022 CDRC Application Completeness REVIEW COMPLETED
12/13/2022 CDRC Review Coordinator REVIEW COMPLETED
12/20/2022 Fire New Construction REVIEW COMPLETED
12/07/2022 OK to Submit - Engineering REVIEW COMPLETED
12/07/2022 OK to Submit - Zoning REVIEW COMPLETED
01/03/2023 ROW Engineering Review REVIEW COMPLETED No Comments