Permit Number: TD-DEV-1122-00029
Parcel: 132131230

Address:
3450 S KINO PW

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE REVIEW v.1

Permit Number - TD-DEV-1122-00029
Review Name: DEVELOPMENT PACKAGE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/21/2022 Commercial Plumbing APPROVED
12/12/2022 Site Landscape APPROVED
12/12/2022 NPPO NOT REQUIRED
12/02/2022 OK to Submit - External Reviewer PC Addressing NOT REQUIRED Good afternoon,



Please remove Pima County Addressing from activity TD-DEV-1122-00029 as it does not require review.





Thank you



Nicholas Jordan

Site Review Project Manager - Addressing Official

Pima County Development Services Department

201 N Stone AV – 1st Floor

Tucson, AZ 85701

(520) 724-9623
12/28/2022 CDRC Post Review PENDING ASSIGNMENT
12/09/2022 Site Engineering REQUIRES RESUBMIT 1. Show dimension from the north side of the structure service window to the proposed drive through vehicular area. Must be one foot or greater per UDC Article 7.4.6.F.2a.
2. Approval required to modify trash enclosure from TSM 8-01.5. Provide prior approval from Environmental Services or submit Technical Standard Modification Request.
3. Show compliance with 8-01.5.3.B – 14 feet by 40 feet operational area.
4. Drainage statement indicates roof drainage on East end of building to basin 2 during first flush. Please show roof drains and method to prevent discharge onto pedestrian circulation path.
5. Drainage statement shows on roof drain on north end of building. This does not match the two roof drains per the Development Package. Please revise drainage statement and or development package.

Joshua Garcia
Engineering Associate
joshua.garcia@tucsonaz.gov
12/05/2022 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL



FROM: PDSD Zoning Review



PROJECT: Bridges B-III Lot 6B – Coffee Bean & Tea Leaf

Development Package (1st Review)

TD-DEV-1122-00029



TRANSMITTAL DATE: December 05, 2022



DUE DATE: December 07, 2022



COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.



This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).



Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is November 06, 2023.



CONTENT REQUIREMENTS



COMMENT: 2-06.4.3 – Provide the development package case number, TD-DEV-1122-00029, adjacent to the title block on all sheets.



2-06.4.7.A.8 - For development package documents provide:



COMMENT: 2-06.4.7.A.8.d – Provide a fully updated Bridges tracking table with the next submittal.



COMMENT: Provide a copy of the Design Review Committee approval letter with the next submittal, see PAD-15 Section C.6.



If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov.



RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
11/07/2022 CDRC Application Completeness REVIEW COMPLETED
12/02/2022 CDRC Review Coordinator REVIEW COMPLETED
12/04/2022 Fire New Construction REVIEW COMPLETED
11/08/2022 OK to Submit - Engineering REVIEW COMPLETED
11/21/2022 OK to Submit - Zoning REVIEW COMPLETED
12/28/2022 ROW Engineering Review REVIEW COMPLETED TD-DEV-1122-00029
3450 S. Kino Blvd.

Comments:
1. Where the adjoining sidewalk of the onsite circulation path, from the property ties to sidewalk along the ROW frontage, a 60” X 60” ADA landing is required. Landings shall be 60” X 60” and not to exceed a 2% cross slope in all directions.

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov