Permit Review Detail
Review Status: In Review
Review Details: DEVELOPMENT PACKAGE NEW v.2
Permit Number - TD-DEV-1026-00271
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Site Zoning Standard | PENDING ASSIGNMENT | |||
| 11/19/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-1026-00271 (1st Review) Project: SFR Grading only – Residential Grading – AE FP Location: 2081 N CORTE EL RANCHO MERLITA Review Date: 11/19/2026 Reviewer: Marco Contreras – Engineering Associate & Joe Macaulay – Civil Engineer Reviewer Contact Information: marco.contreras@tucsonaz.gov Related cases: Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards. The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files. Applicable Code Links for quick/direct reference: City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf City of Tucson Chapter 25: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-18593 Site Engineering Review Comments: 1. Provide the development package case number (TD-DEV-1026-00271) adjacent to the title block on each sheet of the plan set.’ [AM 2-06.4.1.B.6] 2. Provide the general note, “A floodplain use permit and finished floor elevation certificates are required.” [AM 2-06.4.7.B.2.b] 3. The following floodplain information is required to be shown on the development package documents. Revise all applicable sheets accordingly: [AM 2-06.4.9.N & Chapter 26-8.(b).(5)] a. Depict the 100-year associated Water Surface Elevations (WSELs) for all flows of 100 cfs or greater. These values should match does demonstrated in the associated drainage document provided. 4. Update the legend on Cover Sheet to include and define the Limits of Grading line type. All line types, symbols, and keynotes depicted on the grading plans shall be represented in the legend. 5. Provide a dimensioned cross-section detail transecting the proposed building pad, illustrating the full vertical extent of proposed grading, finished pad elevation, and existing natural ground surface elevations. The cross-section shall include sufficient horizontal and vertical scale, with labeled elevation datums referenced to NAVD 88, to clearly demonstrate the relationship between proposed and existing topography. 6. Dimension the footprint of the new SFR on plan view. a. Ensure to denote the height of the new SFR with the SF and FFE information. |
||
| 11/12/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added TEP to Workflow. FYI Notice sent to TEP | ||
| 11/17/2026 | Commercial Plumbing Standard | REVIEW COMPLETED | Grading permit only | ||
| 11/12/2026 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 11/13/2026 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | CDRC Sent FYI to TEP. No further action needed | ||
| 11/06/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 11/10/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED |