10/30/2026 CDRC Post Review Express PENDING ASSIGNMENT
10/30/2026 CDRC Review Coordinator Express PENDING ASSIGNMENT
10/30/2026 Commercial Plumbing Standard PENDING ASSIGNMENT
10/30/2026 Site Engineering Standard PENDING ASSIGNMENT
10/30/2026 Site Zoning Standard PENDING ASSIGNMENT
10/29/2026 OK to Submit - Engineering Fast REQUIRES RESUBMIT Permit Activity Number: TD-DEV-1026-00271 (1st Review)
Project: Development Package for new ground up classroom, common area, offices, storage, minor food service metal building structure with common material infill detached building addition to Rising Star Church
Location: 2081 N CORTE EL RANCHO MERLITA
Review Date: 10/29/2026
Reviewer: Marco Contreras – Engineering Associate
Reviewer Contact Information: marco.contreras@tucsonaz.gov
Related cases:

Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards.
The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files.

Applicable Code Links for quick/direct reference:
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf
City of Tucson Chapter 25: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-18593

Site Engineering Review Comments:
In compliance with general note #11 per final plat for EL RANCHO MERLITA – “Development shall not encroach into the 100-year floodplains or erosion hazard setbacks delineated by this plat”

1. As previously communicated through email – in order to avoid the requirement of the re-platting process for this property as posed by the above referenced subdivision standard – It will be required that a full hydrology report be completed and submitted with the current application. The following items will need to be addressed in the report:
a. It will need to be demonstrated that the proposed SFR development does not create “Encroachment” into the existing floodplain & alter existing conditions - TC Sec. 26-5.2: Adverse Impacts – Ensure the report evaluates and discusses whether increased velocities, WSELs, flood prone area, or diverted flows create adverse impacts to adjacent public or private properties. Quantify the changes at adjacent structures. For example, the existing structure to the north may be slab-on-grade, so an increase of 0.1 ft could constitute an increased flood hazard. Where impacts are identified, provide mitigation or demonstrate that no adverse impact results.
2. As currently formatted – the grading plan does not provide enough elevation data (both existing and proposed). For resubmission, please update the grading plan to carry more spot elevations that show reasonable building pad construction extent as well as demonstrating effective drainage away from the proposed SFR.
3. As currently shown it appears the project may be triggering differential grading, which is where 2-ft of fill is used on top of existing elevations, as such please keep in mind this may require the project to go through the differential grading process once brought in for full review. [TSM 2-01.8.1]
4. Please provide an Earthwork table - Cut and fill quantities, including total area of disturbance (sq. ft.) and earthwork volumes
10/30/2026 OK to Submit - Zoning Fast REQUIRES RESUBMIT 1. COMMENT: Address Site Engineering comments.

Loran Shamis
loran.shamis@tucsonaz.gov
10/27/2026 CDRC Application Completeness Express REVIEW COMPLETED