Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-1025-00258
Parcel: 114512110

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-1025-00258
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/14/2025 CDRC Review Coordinator Express PENDING ASSIGNMENT
10/14/2025 Commercial Plumbing Standard PENDING ASSIGNMENT
10/14/2025 Fire New Construction Standard PENDING ASSIGNMENT
10/14/2025 NPPO Standard PENDING ASSIGNMENT
10/14/2025 ROW Engineering Review Standard PENDING ASSIGNMENT
10/14/2025 Site Engineering Standard PENDING ASSIGNMENT
10/14/2025 Site Landscape Standard PENDING ASSIGNMENT
10/14/2025 Site Zoning Standard PENDING ASSIGNMENT
10/14/2025 OK to Submit - Engineering Fast REQUIRES RESUBMIT Permit: TD-DEV-1025-00258
Location: 9015 E TANQUE VERDE RD
Review Date: 10/14/2025
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf

Site Engineering Comments:
1. Application not sufficient, the site at 9015 E Tanque Verde Rd is designated as critical basin and will require that the drainage report be revised to show that full compliance with first flush retention/ critical basin detention requirements are met with this development.
2. Due to the site being greater than one acre and subject to detention requirements, the drainage statement provided will not be sufficient. For resubmission, please provide a full drainage report following the format requirements laid out within chapter 10 of the Design Standards for stormwater detention and retention. Additional format requirements can be found within Section 2.3.1 of the Drainage Manual.
If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
10/14/2025 OK to Submit - Zoning Fast REVIEW COMPLETED