Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.3
Permit Number - TD-DEV-1023-00421
Review Name: DEVELOPMENT PACKAGE NEW v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/24/2025 | Site Engineering | APPROVED | |||
| 04/24/2025 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 04/15/2025 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Chevron – 3370 N. Country Club Development Package (2nd Review) TD-DEV-1023-00421 TRANSMITTAL DATE: April 15, 2025 DUE DATE: April 14, 2025 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is November 13, 2024. 2-06.4.0 CONTENT REQUIREMENTS 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 1. This comment was not fully addressed. Provide a PAAL width dimension for the 5 northernmost vehicle parking spaces. COMMENT: 2-06.4.9.H.5 – As new sidewalks are proposed with a reconfiguration of the vehicle parking area provide PAAL width dimensions on the plan. 2. COMMENT: 2-06.4.9.L – As work is proposed within the COT Right-of-Way (ROW) a Temporary Revokable Easements must be secured. Contact COT Transportation and Mobility Real Estate Division to secure this easement. 3. This comment was not addressed correctly. Based on a future ROW of 100’ for Country Club, the ½ ROW should be 50’ not 40’ as shown on the plan. One the future ROW is shown correctly a Board of Adjustment maybe required. COMMENT: 2-06.4.9.O – The west street perimeter yard setback listed under General Note 14 is not correct. Per UDC Article 6.4.5.C.2.a, for nonresidential and multifamily development abutting on Arterial or “Collector street the minimum required street perimeter yard is ten feet, as measured from the existing or future property line as determined by the adopted Major Streets and Routes Plan, whichever is greater. Based on the street dimensions shown on this plan for Country Club Rd., County Club is not at full width, 100’ based on the COT MS&R map. Clearly show the future right-of-way and provide a setback dimension to the street future property line. A Board of Adjustment for Variance may be required. 4. COMMENT: 2-06.4.9.Q – Provide the clear height of the proposed fuel canopy for the area where the one-way access lane goes under the canopy. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised development package as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |