Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: AS-BUILT v.1
Permit Number - TD-DEV-1022-00007
Review Name: AS-BUILT v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/28/2025 | Site Zoning Fast | APPROVED | |||
02/28/2025 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
02/28/2025 | Site Engineering Fast | REQUIRES RESUBMIT | 1. The 6" berm along the front of the gate at the west end of the parking area doesn't seem sufficient to stop water from onsite discharging through the gate, I would suggest a grated trench across the gate that pipes into the new catch basin. 2. The 3' deep retention/detention basin is going to require infiltration tests to confirm that the drain-down time meets code. 3. Please include the updated drainage report that shows that the new retention/detention basin with rock well will be able handle the increased discharges it is receiving with the changes to the site. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |