Permit Review Detail
Review Status: In Review
Review Details: DEVELOPMENT PACKAGE NEW v.2
Permit Number - TD-DEV-0926-00251
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Design Review Standard | PENDING ASSIGNMENT | |||
| 11/06/2026 | NPPO Standard | REQUIRES RESUBMIT | Please see site landscape comments for NPPO Waiver or a note with regard the the site being void of vegetation and NPPO not being necessary for this site. Thank you. Chad Keller, PLA chad.keller@tucsonaz.gov |
||
| 11/05/2026 | ROW Engineering Review Standard | REQUIRES RESUBMIT | Sidewalk required along street frontage. Driveway should be constructed per COT SD 206. Unused curb openings shall be closed. |
||
| 11/02/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0926-00251 Project: Tucson Water Equipment Well Site Location: 1647 N BELVEDERE AV Review Date: 11/2/2026 Reviewer: Joe Macaulay – Civil Engineer – Site Development Reviewer Contact Information: joe.macaulay@tucsonaz.gov Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards. The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files. Applicable Code Links for quick/direct reference: City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf City of Tucson Chapter 25: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-18593 Site Engineering Review Comments: 1. Provide the development package case number, TD-DEV-0926-00251, adjacent to the title block on all sheets. 2. Please add the name, mailing address, email and phone number of the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents on the plan set cover sheet. [AM 2-06.4.1.A.1] 3. Please add the following Drainage General Notes: a. “Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public.” a. The turning radius and approach path of a standard collection vehicle for each enclosure(s) location. b. Demonstration that the required back-up distance and maneuverability clearances are achievable within the proposed drive aisle and parking layout without conflict. c. Confirmation that collection vehicles can enter and exit the site in a forward direction, or, if backing is required, that the back-up distance and sight conditions comply with the requirements of TSM 8-01.5.3.F. 4. The Demolition Sheet (Sheet 3) calls out CMU walls with a height of 7’ tall which is different than the 8’ high walls shown on the Mechanical Sheet (Sheet 4). Please revise sheets to match proposed wall heights. a. As the proposed walls are greater than 7’, it will be required that a separate structural wall permit with structural calculations/drawings be submitted for construction of the wall. 5. Provide the following general note: Retaining walls and/or screen walls referenced on this plan are to be designed by others. Elevations shown hereon are for reference only. The contractor shall confirm exact elevations. All retaining/structural walls and/or screen walls require a separate building permit and are not covered under the grading permit for this project. 6. Please revise Demolition Sheet section 8 & 9 callouts “A.B.C. Per P.A.G. Section 303 (Compact to 100% Min. Density)” to say “Max. Density” instead of “Min…” per section P.A.G. Section 303. Drainage and Grading Comments: 7. A floodplain use (FPU) permit has been created for this permit, TE-FPU-1126-00439. The lot exists in a regulated FEMA Floodplain Zone “AE” associated with Midway Wash, and a floodplain use (FPU) permit with elevation certification is needed for all building permits. Drainage Report Comments: 8. The data measurement from Map Tucson on page 5 of the submitted Floodplain Data Letter is not measured from the correct FIS (brown) cross sections and should be recalculated using the same process with these to determine the required BFE and FFE for the well pad. 9. Based upon the revised BFE determined from comment #8 above, the well pad will need to be raised up to the required 2ft elevation above the BFE for critical infrastructure as opposed to the well cover currently shown in the plans. Please revise. |
||
| 11/06/2026 | Site Landscape Standard | REQUIRES RESUBMIT | PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, PLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: EQUIP WELL B-114A PROJECT INCLUDE POCKET PARK ON CORNER OF PIMA AND BELVEDERE ACTIVITY NO: TD-DEV-0926-00251 ADDRESS: 1647 N BELVEDERE AV ZONING: RESIDENCE ZONE (R-2) LAND USE PER UDC TABLE 7.6.4-1: UTILITY SERVICE 11.6.2026 THE PROPOSED PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH APPLICABLE DEVELOPMENT STANDARDS FOR SITE LANDSCAPE, NATIVE PLANTS, AND RAINWATER HARVESTING, PER-THE-CITY OF TUCSON UNIFIED DEVELOPMENT CODE (UDC), TECHNICAL STANDARDS MANUAL (TSM), AND ADMINISTRATIVE MANUAL (AM). RESUBMIT REVISED DRAWINGS ALONG WITH A DETAILED RESPONSE LETTER, STATING HOW ALL SITE LANDSCAPE AND NPPO SECTION REVIEW COMMENTS HAVE BEEN ADDRESSED. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. Prior to site landscape approval, ensure that Site Zoning and Site Engineering comments are fully addressed. 2. The ROW planting notes are great. With the next submittal include an approval letter from DTM for use of the ROW for the plants and for the required irrigation. Contact David Marhefka, PLA for review and approval and the acceptance letter. 3. Label the existing and future ROW lines on all plans in the set. 4. Label and graphically depict the SVTs as they relate to the plant material that may be planted within them. The access drive should include the SVTs. 5. Most of the areas that have plants that are not currently depressed should be depressed even if it is just slightly for rainfall only catchment within the basin itself. The additional depressions will fall in line with the intentions of the standards for the proposed codes for the Living Landscapes Initiative and LID. This is not a requirement and if there are particular design constraints that may prevent this, then that will be understood. If you choose to include the depression linework, then just show the top contour shape and bottom of basin contour with a depth of 2, 4, 6 inches. 6. This site is mostly void of plants. Include the NPPO Waiver for this site. Or add a note to the planting plan that states that there are no protected native plants on site. This is for our records and for yours. 7. Include the Activity Number TD-DEV-0926-00251 on all sheets in the plan set. Thank you. CHAD KELLER, PLA LANDSCAPE ARCHITECT CITY OF TUCSON, PDSD, SITE REVIEW SECTION CHAD.KELLER@TUCSONAZ.GOV 520.837.4923 |
||
| 11/04/2026 | Site Zoning Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL REVIEWED BY: Jeffrey Cassidy – Planner I PDSD Current Zoning Commercial Review Section PROJECT: Restricted Record-Equip well B-114A project include pocket park on corner of Pima and Belvedere Development Package (1st Review) TD-DEV-0926-00251 1647 N BELVEDERE AV TUCSON, AZ 85712 R-2 Zoning TRANSMITTAL DATE: November 04, 2026 Per UDC Section 3.3.3.G.5.c, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year expiration date is September 24, 2027. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-8753 1. COMMENT: Distribution system use is only permitted in the R-2 zone via Special Exception Zoning Examiner procedure. Refer to UDC 3.4.3 for next steps: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-1048 and contact Carver.Struve@tucsonaz.gov for more information. Additionally, on the cover sheet, general note #3 refers to a Special Exception Procedure. This should be listed as 3.4.3 (as opposed to 2.4.3 currently). 2. COMMENT: Provide the name and contact information for the primary property owner and consultants of the site and this project. (AM 2-06.4.1.A.1). 3. COMMENT: The proposed project appears to consider two lots,122-12-3020 and 122-12-303A, as a single site, under single ownership, and as part of a unified development. As such, a lot combination processed through Pima County could be required prior to final approval of this project. A link to the County Application: https://www.asr.pima.gov/Downloads/Forms/ComboRequest.pdf. Provide resulting legal description from lot combination. (AM 2-06.4.1.B.2). 4. COMMENT: Provide recording information from lot combination. (AM 2-06.4.1.B.3). 5. COMMENT: Provide the development package case number, TD-DEV-0926-00251, adjacent to the title block on each sheet. (AM 2-06.4.1.B.6). 6. COMMENT: On the cover sheet, add general note(s) indicate that this development is subject to the Major Streets and Routes (MS&R) per UDC 5.4, (AM 2-06.4.2.F). 7. COMMENT: Provide percentage of vehicular use area (parking, driveway, back-up spur, etc). (AM 2-06.4.2.I). 8. COMMENT: On the cover sheet, add the general note: “Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public.” (AM 2-06.4.4.D). 9. COMMENT: Provide updated property line lengths once lot combination has been processed. (AM 2-06.4.7.A). 10. COMMENT: On the cover sheet, update the setbacks to West and South: 10’-0” or ¾ building height (whichever is greater); North: 10’-0” and East: 20’-0”. (AM 2-06.4.7.G). Additionally, per Use Specific Standard 4.9.11.A.1., “The setback of the facility, including walls or equipment, shall be 20’-0” from any adjacent residential zone”. Update both structure locations to meet this code standard. 11. COMMENT: Per UDC 6.6.2.I, the maximum height of a wall or fence within a perimeter yard shall be 6’-0” measured from above finish grade to the top of the wall at any point along the wall run; however, the wall or fence may be higher than 6’-0”, but no higher than 10’-0”, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear Perimeter Yard.). A. Over 6'-0” and up to 8'-0” tall and not meeting 75% unobstructed view criteria - A Design Development Option (DDO) Special Application Zoning Approval Process is required. This is an Administrative Review process with public notice. B. A 7’-0” tall wall must be structurally engineered by a state registered professional. The proposed wall exceeds the 6.6.2.I standard along the south and west locations. Locating the wall just beyond the 20’-0” setback (20’-1”) will not require a DDO. Email the zoning reviewer if you plan to pursue a DDO route at jeffrey.cassidy@tucsonaz.gov while referring to the application instructions provided below. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration . To submit a DDO application, apply for a new sub-record under this permit at TDC Online. In order to get this specific review scheduled and if you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. Zoning cannot approve the zoning review portion of the permit until the DDO has been approved. 12. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please resubmit revised drawings and any corrected plans along with a detailed response letter, stating how all Site Zoning Review comments were addressed. **Instructions for resubmittal - www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. ***For additional information on the standards presented in this memo, please refer to the City of Tucson Administrative Manual Section 2-06 or Technical Standards noted in the comments. If you have any questions about this transmittal, please contact Jeffrey.cassidy@tucsonaz.gov |
||
| 11/05/2026 | Transportation Landscape Review Standard | REQUIRES RESUBMIT | Please see comments on the plans and the Drainage Statement. | ||
| 10/15/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC Sent FYI Notice to PAG, USPS, SWG, and TEP. | ||
| 10/21/2026 | Commercial Plumbing Standard | REVIEW COMPLETED | |||
| 10/15/2026 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 10/15/2026 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 10/15/2026 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 10/15/2026 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 11/04/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 10/14/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 10/14/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED | |||
| 11/03/2026 | ROW Review | REVIEW COMPLETED |