| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | External Reviewers - Tucson Airport Authority Standard | PENDING ASSIGNMENT | |||
| N/A | External Reviewers - Tucson Electric Power (TEP) Standard | PENDING ASSIGNMENT | |||
| 12/31/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | ACTIVITY NO. TD-DEV-0925-00238 ADDRESS/PARCEL: (1025 E BENSON HY TUCSON, AZ 85713) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. COMMENTS: 1. Revise the site plan to include the existing utility information required by the City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2018: a. The location and size of both the existing water meter and the reduced pressure backflow preventer assembly, water lines, and fire hydrants. b. The location and size of sanitary and storm sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; along with the Pima County Wastewater Management Department (PCWMD) reference number. c. The points of connection to existing public sewers. d. The locations of gas lines, electric and telephone lines, poles, and communications cables, on-ground junction boxes, and street lights. e. Any existing or proposed utility easements f. The first floor elevation for each building |
||
| 12/12/2025 | External Reviewers - Pima County Addressing Standard | REQUIRES RESUBMIT | Pima County Addressing is returning TD-DEV-0925-00238 with the attached comments. Thank you, David Wilging Planner I - Addressing Division Pima County Development Services 201 N. Stone Avenue 1st Floor Tucson, Arizona 85701 520-724-6381 |
||
| 12/31/2025 | Fire New Construction Standard | REQUIRES RESUBMIT | Add a note stating knox key switch will be provided for electric vehicle gates and knox key boxes for ped gates. john.vincent@tucsonaz.gov 5203495581 |
||
| 01/02/2026 | NPPO Standard | REQUIRES RESUBMIT | See Site Landscape comments for NPPO Waiver requirement. Thank you. Chad Keller, RLA chad.keller@tucsonaz.gov |
||
| 12/30/2025 | ROW Engineering Review Standard | REQUIRES RESUBMIT | Sidewalk required along street frontage. Driveways should be constructed to PAG SD 206. |
||
| 12/11/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TD-DEV-0925-00238 Location: 1025 E BENSON HY Review Date: 12/11/2025 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Manual (TM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Comments: 1. Provide the development package case number, TD-DEV-0925-00238, adjacent to the title block on all sheets. 2. Provide the general note “The developer, any successors and assigns, will hold the City of Tucson, its officers, employees, and agents harmless from any and all claims for damages related to the use of this development as shown hereon, now and in the future, by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall.” Administrative Manual 2-06.4.7.B.1 3. Provide the general note “Drainage will remain in its natural state and will not be altered, disturbed, or obstructed other than as shown on this site plan.” AM 2-06.4.7.B.3 4. Provide the general note “No structure or vegetation shall be located or maintained so as to interfere with the sight visibility triangles in accordance with Section 10-01.5.0, Sight Visibility, of the Technical Standards Manual.” AM 2-06.4.7.C.2 5. Provide Sight visibility triangles for the site entrance along Country club in compliance with TSM 10-01.5.0 It should be noted that Benson HY is designated as Arterial RD for reference when reviewing the SVT tables. Solid waste collection and disposal comments: 6. Provide trash enclosure detail in compliance with TSM 8-01.5.0 7. Provide the Waste Stream Calculations for the entire site according to TSM 8-01.8.0 Pedestrian circulation Comments: 8. Pedestrian circulation is required to connect all buildings, dumpster areas, common areas, and the sidewalk on all the street frontages per TSM 7-01.3.3. Demonstrate how the site connects to the dumpster enclosure as well as the ADA parking spots. Also demonstrate how Pedestrian circulation will potentially connect to straight frontage along Benson HY. a. The ADA parking spots with ramp on the Northeast side of the property is not compliant as they exist currently due to requiring an individual walk directly into the PAAL to access said ramps. It will be required that all ADA accessible ramps and pathways be updated to current ADA and COT standards. 9. Dimension PAAL widths, parking spaces and sidewalks in compliance with UDC 7.4.6 10. Wheel stops will be required at all parking spaces adjacent to the sidewalks so as not to reduce the sidewalk path to less than 4 feet. UDC 7.4.6 Sidewalks that are 6 and a half feet or wider will not require adjacent parking spaces to have wheel stops 11. Provide a keynote/callout for all building downspouts and sidewalk scuppers for the building to ensure that stormwater from roof drains, up to and including flow from the ten-year storm event, does not pass over sidewalks per Technical Standards Manual 7-01.4.3E. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 01/02/2026 | Site Landscape Standard | REQUIRES RESUBMIT | PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: CONVERT (E) MOTEL INTO MULTI FAMILY APARTMENTS: CHANGE OF USE ACTIVITY NO: TD-DEV-0925-00238 ADDRESS: 1025 E BENSON HY ZONING: C-2 COMMERCIAL ZONE LAND USE: CHANGE OF USE/COMMERCIAL/UPDATE TO CURRENT SITE LANDSCAPE CODE REQUIREMENTS 01.02.2026 THE PROPOSED PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH APPLICABLE DEVELOPMENT STANDARDS PER THE CITY OF TUCSON UNIFIED DEVELOPMENT CODE (UDC), TECHNICAL STANDARDS MANUAL (TSM), AND ADMINISTRATIVE MANUAL (AM) FOR SITE LANDSCAPE, NATIVE PLANTS, AND RAINWATER HARVESTING. RESUBMIT REVISED DRAWINGS ALONG WITH A DETAILED RESPONSE LETTER, STATING HOW ALL OF THE SITE LANDSCAPE AND NPPO SECTION REVIEW COMMENTS HAVE BEEN ADDRESSED. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. Include a planting plan and details for the street landscape border and parking lot trees. 2. Include an irrigation plan and details for the landscape border and parking lot trees. 3. Note: This is an existing site and commercial rainwater harvesting is not required due to the existing nature of the site. We do require that the new tree planting areas be depressed 6 inches for rainfall only catchment. 4. Parking lot canopy tree requirement: 1 canopy tree per 4 parking spaces; 236 parking spaces exist; 236/4 = 59 canopy trees required. Note: The required planting area for trees is 34 square feet depressed 6 inches and irrigation is required for tree establishment. 5. Street landscape border along Benson Highway: The border will likely need a few shrubs and possibly a tree or two to meet the standards set forth in UDC 7.6. I tree per 33 linear feet and 50 percent vegetative cover within the 10-foot width border is required. Update the street landscape border to meet these standards. Outline on the planting plan how these standards have been met. 6. It is recommended to provide an inventory of all of the existing plant material on site. Provide written quantities and plant symbology. The symbols should be grayed back as to not interfere with what is being proposed to meet the UDC Site Landscape Requirements. Consultation with a local landscape architect to prepare the landscape and irrigation plans is also recommended. 7. Native plants will likely not be disturbed with these updates and improvements. A NPPO Waiver is required for all sites where work is being completed. This is for record keeping only. A link to the fillable NPPO Waiver is attached below. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/applicationsforms/nppoapp-2025-v.2-fillable-1.pdf 8. Site Landscape redlines reiterating the above stated comments are included on the submitted plans for review. If there are questions about the above comments, please send an email. Contact information located below. Thank you. Chad Keller, RLA Landscape Architect chad.keller@tucsonaz.gov |
||
| 12/30/2025 | Site Zoning Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Fernando Garcia Site Zoning Review Section PROJECT: Development Package 1025 E Benson Hy, Tucson, AZ TD-DEV-0925-00238 TRANSMITTAL DATE: December 20, 2025 DUE DATE: December 31, 2025 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is December 24, 2026. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) 2-06.3.0 FORMAT REQUIREMENTS 2-06.3.7 - A small, project-location map shall be provided in the upper right corner of the cover sheet. 1. COMMENT: 2-06.3.7 - Provide requested information. See redline on sheet T1. 2-06.3.8 - The north arrow, contour interval, and scale as applicable to each sheet should be placed together in the upper right corner of each sheet. 2. COMMENT: 2-06.3.8 – Provide requested information. See redline on sheet T1. 2-06.3.12 - An index of sheets in the development package shall be provided on the first sheet. 3. COMMENT: 2-06.3.12 – Remove sheets A-2.3, A.2-4, A-2.5, A-2.6, and A-2.7. These are building plans and will be reviewed on the separate construction building permits. CONTENT REQUIREMENTS 2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. The applicable registration or license number shall be provided if prepared by or with the assistance of a registered professional, such as a surveyor, architect, landscape architect, or engineer. All sealing shall be consistent with Arizona Board of Technical Registration guidelines. 4. COMMENT: 2-06.4.1 – Provide requested information. See redline on sheet T1. 2-06.4.2.B - A brief legal description and a statement as to whether the project is a re-subdivision are to be provided. On re-subdivisions, provide the recording information of the existing subdivision plat; 5. COMMENT: 2-06.4.2.B – Provide legal description of the property under the location map. The legal description is “PT OF SELY 508.57' M/L OF NWLY 928.74' M/L LYG E OF PARK & BETWEEN HWY & BENSON HWY E2 SW4 5.64 AC SEC 30-14-14” 2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet. 6. COMMENT: 2-06.4.3 - Provide the development package case number, TD-DEV-0925-00238, adjacent to the title block on each sheet. 2-06.4.4 - The project-location map to be located on the first sheet of the development package in the upper right corner, shall cover approximately one square mile, be drawn at a minimum scale of three inch equals one mile, and provide the following information. 7. COMMENT: 2-06.4.4 - Provide requested information. See redline on sheet T1. 2-06.4.4.A - Show the subject property approximately centered within the one square mile area; 8. COMMENT: 2-06.4.4.A - Provide requested information. See redline on sheet T1. 2-06.4.4.B - Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property; and, 9. COMMENT: 2-06.4.4.B - Provide requested information. See redline on sheet T1. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. Zoning and Land Use Notes 2-06.4.7.A.1 - List as a general note: "Existing zoning is ____." 10. COMMENT: 2-06.4.7.A.1 - Provide requested information. See redline on sheet T1. 2-06.4.7.A.2 - List the gross area of the site/subdivision by square footage and acreage. 11. COMMENT: 2-06.4.7.A.2 - Provide requested information. See redline on sheet T1. 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. 12. COMMENT: 2-06.4.7.A.4 - Provide requested information. See redline on sheet T1. The existing use is “Traveler’s Accommodation”. The proposed use is “Multifamily Development”. 2-06.4.7.A.6 - If a plan or plat is prepared in conjunction with other applications or overlays or the parcel being developed is subject to conditions of an application processed previously, additional information must be added to the plan. Such applications and overlays include, but are not limited to: annexations; rezonings; special exceptions; Board of Adjustment variances; Design Development Options; Technical Standard Modification Request; overlays (Airport Environs Zone, Environmental Resource Zone, Gateway Corridor Zone, Hillside Development Zone, Historic Preservation Zone, Major Streets and Routes, Rio Nuevo District, Scenic Corridor Zone, WASH); Modification of Development Regulations through the Downtown Area Infill Incentive District or Rio Nuevo District; Downtown Heritage Incentive Zone; or, Design Review Board. Provide the following information on the plan. 13. COMMENT: 2-06.4.7.A.6 – Include a note stating “this project is designed to meet the overlay zone(s) criteria UDC Article 5.4 Major Streets and Routes Setback Zone (MS&R). 2-06.4.7.A.8 - For development package documents provide: 2-06.4.7.A.8.a - Floor area for each building; 14. COMMENT: 2-06.4.7.A.8.a - Provide requested information. 2-06.4.7.A.8.b - Percentage and area in square feet of building and accessory building coverage; 15. COMMENT: 2-06.4.7.A.8.b - Provide requested information. 2-06.4.7.A.8.c - Percentage of building, lot area, or vehicular use area expansion. If the building(s) or lot area have been previously expanded, those calculations shall be included; and, 16. COMMENT: 2-06.4.7.A.8.c - Provide requested information. If none, state so. 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 2-06.4.8.A - Provide site boundary/subdivision perimeter information, including bearing in degrees, minutes, and seconds, with basis for bearing noted, together with distances in feet, to hundredths of a foot, or other functional reference system. 17. COMMENT: 2-06.4.8.A – Provide requested information. 2-06.4.8.B - All easements shall be drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated. Blanket easements should be listed in the notes, together with recordation data and their proposed status. Should an easement not be in use and be proposed for vacation or have been abandoned, so indicate. However, should the easement be in conflict with any proposed building location, vacation of the easement shall occur prior to approval of plan unless written permission from easement holder(s) is provided. 18. COMMENT: 2-06.4.8.B - Provide requested information. 2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks. 19. COMMENT: 2-06.4.8.C – Provide requested information. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 2-06.4.9.A - Draw in all proposed lot lines with approximate distances and measurements. 20. COMMENT: 2-06.4.9.A – Provide requested information. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. If the property is being rezoned, use those boundaries and classifications. The basis for this requirement is that some zoning requirements on a project are based on the zoning classification of adjacent property. Also, in some instances, each zone has to be taken into consideration on property that is split by two or more zoning classifications, as each may have different requirements. 21. COMMENT: 2-06.4.9.F – Provide requested information. Indicate the zoning boundary change between C-2 and I-1. 2-06.4.9.G - If the project is to be phased, provide calculations, setbacks, etc., to indicate that each phase complies with all requirements as a separate entity. Show phase lines on the drawing. Show and label any temporary improvements that may be needed to make the site function for each phase as one entity. If such temporary improvements are off the site of the phase under consideration, a temporary easement or other legal documentation to assure legal use of the property is required. Note recording information. 22. COMMENT: 2-06.4.9.G – If phasing is planned, indicate howso. 2-06.4.9.H.5 - If utilizing parking area access lanes (PAALs), they shall be designed in accordance with Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. 23. COMMENT: 2-06.4.9.H.5 – Dimension width of all parking area access lanes. 2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. 24. COMMENT: 2-06.4.9.H.5.a – Provide a typical parking space detail and an accessible parking space detail, or show dimensions on the plan drawing. Include vehicular parking as part of a parking calculations table on sheet 1. 2-06.4.9.H.5.d - Show bicycle parking facilities fully dimensioned. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Provide, as a note, calculations for short and long term bicycle spaces required and provided. 25. COMMENT: 2-06.4.9.H.5.d – Provide requested information. Include bicycle parking as part of a parking calculations table on sheet 1. 2-06.4.9.O - All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown. 26. COMMENT: 2-06.4.9.O – Provide setback dimensions to adjacent street future right-of-way. 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s). 27. COMMENT: 2-06.4.9.Q – Provide height of buildings. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. 28. COMMENT: 2-06.4.9.R – Dimension all sidewalks and crosswalks. 2-06.4.9.T - Show refuse collection areas, including locations of dumpsters, screening location and materials, and vehicle maneuverability, fully dimensioned, and access route. If dumpster service is not proposed, indicate type of service. For specific information on refuse collection, refer to Section 8-01.0.0, Solid Waste and Recycle Disposal, Collection, and Storage, of the Technical Standards Manual. Refuse collection on all projects shall be designed based on that section, even if collection is to be contracted to a private firm. 29. COMMENT: 2-06.4.9.T – Provide requested information. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, contact Site Zoning Reviewer Fernando Garcia at fernando.garcia2@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package and comment response letter. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/pdsd/website/Resubmittals.pdf. |
||
| 12/09/2025 | CDRC Review Coordinator Express | REVIEW COMPLETED | EXTERNAL REVIEWERS CDRC added: ADOT, TEP, TAA, ADDRESSING , SWG, USPS, and PAG to the workflow. Review request email sent to ADOT, TEP, TAA, ADDRESSING and FYI email sent to, SWG USPS PAG. |
||
| 01/06/2026 | External Reviewers - Arizona Department of Transportation (ADOT) Standard | REVIEW COMPLETED | December 30, 2025 Planning and Development Services City of Tucson 201 North Stone Avenue Tucson, AZ. 85701 RE: TD-DEV-0925-00238, 1st Submittal, Building: North Building: convert (E) MOTEL into MULTI FAMILY APARTMENTS/ add new electric stove kitchen sink, fridge & counters./ 1025 E. Benson Highway, Tucson, AZ. 85713, Received December 9, 2025 To whom this may concern, Thank you for the opportunity to comment on TD-DEV-0925-00238, 1st Submittal, a development plan converting an existing motel into multifamily apartments at 1025 E. Benson Highway. This development is located in the S.E. quarter of the S.W. quarter of Section 30, Township 14S, Range 14E, of the Gila and Salt River Meridian. The development site occupies parcel number 132-13-0490, covers approximately 5.39 ± acres, and is zoned as Commercial 2 Zone (C-2). The nearest major roadway intersection is South Park Avenue and East Benson Highway, approximately 200 feet to the northwest of the subject development. This site does lie within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace. The Tucson Airport Authority approves the 1st submittal of this project and is not requiring a resubmittal of this project. Although this project does not propose a change in plan designation or zoning the Tucson Airport Authority highly recommends the applicant add the following notes into the general notes of the revised development plan. This project is located approximately 3.25 miles northwest of Tucson International Airport and is within FAA traffic pattern airspace, an area which would be subject to aircraft overflight and noise due to being in close proximity to Tucson International Airport. The proposed notes would provide a means of assuring that future owners and tenants of the property are aware they are in proximity an airport and further assures the continued right of the City of Tucson, Tucson Airport Authority, and all persons lawfully utilizing the Tucson International Airport the right to utilize the airspace above or near the property. This would be accomplished through the property owner recording the Avigation Easement and providing the Airport Disclosure Statement to the new residents of all residential uses. The Tucson Airport Authority believes the proposed note helps to support the City of Tucson Airport Environs Overlay Zone and supports Plan Tucson – Regional and Global Positioning policy 4 (RG-4). 1. "That prior to the City's approval of the proposed development, the property owner must record the Avigation Easement that discloses the existence and operational characteristics of the Tucson International Airport to future owners or tenants of the property and further conveys the right to the public to lawfully use the airspace above the property. The Avigation Easement shall be recorded in a manner with the Pima County recorder which shall document it as having title liability. The content of such documents shall be according to the form and instructions provided.” The current property owner or person authorized to sign on behalf of the current property owner must complete, sign, and record the Avigation Easement. Please record the Avigation Easement with the Pima County Recorder’s Office. Then send a complete copy of the recorded easement document to Tucson Airport Authority by either email (send to srobidoux@flytucson.com) or to the mailing address provided below. Scott Robidoux Manager of Planning Tucson Airport Authority 7250 South Tucson Blvd, Suite 300 Tucson, AZ 85756” 2. Applicable to residential uses only “The property owner/developer/applicant must provide the Airport Disclosure Statement form, at time of sale, to the new property owners with all new unit purchases. In the event the development of any residential uses does not involve the sale of new units but is instead offering rental residential units to the public, the new tenant of the rental unit must be provided a copy of the Airport Disclosure Statement form. The intent of the Airport Disclosure Statement form is to educate and notify the new residents that they are living near an airport. The content of such documents shall be according to the form and instructions provided.” The property owner (for itself or its tenants) shall forward a signed copy of the Airport Disclosure Statement form to the Tucson Airport Authority within ten (10) days of signature, using the Scott Robidoux mailing address provided above. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520- 573-4811. Respectfully, Scott Robidoux, C.M. Manager of Planning cc file |
||
| 12/12/2025 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 12/09/2025 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 12/09/2025 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 12/08/2025 | OK to Submit - Zoning Fast | REVIEW COMPLETED |