Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.2
Permit Number - TD-DEV-0825-00208
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/19/2025 | NPPO Standard | REQUIRES RESUBMIT | Please see Site Landscape and Site Zoning comments. Thank you. Chad Keller, RLA chad.keller@tucsonaz.gov |
||
| 11/26/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TD-DEV-0825-00208 Location: 26 W ROGER RD Review Date: 11/26/2025 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Manual (TM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Comments: 1. Provide a keynote for all building downspouts and sidewalk scuppers for the building to ensure that stormwater from roof drains, up to and including flow from the ten-year storm event, does not pass over sidewalks per Technical Standards Manual 7-01.4.3E. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 12/19/2025 | Site Landscape Standard | REQUIRES RESUBMIT | PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: MULTI FAMILY DUPLEXES FOR 26 WEST ROGER ROAD ACTIVITY NO: TD-DEV-0825-00208 ADDRESS: 26 W ROGER RD ZONING: R-2 RESIDENCE ZONE LAND USE: MULTIFAMILY 12.19.2025 THIS PLAN HAS BEEN REVIEWED FOR COMPLIANCE WITH APPLICABLE DEVELOPMENT CRITERIA IN THE CITY OF TUCSON UNIFIED DEVELOPMENT CODE (UDC) ADMINISTRATIVE MANUAL (AM) SECTION 2-11 AND TECHNICAL MANUAL (TM) SECTION FOR LANDSCAPE, NATIVE PLANTS, AND WATER HARVESTING. PLEASE RESUBMIT REVISED DRAWINGS ALONG WITH A DETAILED RESPONSE LETTER, WHICH STATES HOW ALL OF THE SITE LANDSCAPE AND NPPO SECTION REVIEW COMMENTS HAVE BEEN ADDRESSED. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. The plans have improved since the previous review for site landscape. See Site Zoning comments as they will affect the overall layout of the required elements for landscape. Thank you. Chad Keller, RLA Landscape Architect chad.keller@tucsonaz.gov 520.837.4923 |
||
| 12/17/2025 | Site Zoning Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Fernando Garcia PDSD Site Zoning Review Section PROJECT: Development Package TD-DEV-0825-00208 (2nd Review) 26 W Roger Rd, Tucson, AZ 85705 TRANSMITTAL DATE: December 17, 2025 DUE DATE: December 16, 2025 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is August 12, 2026. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) 2-06.4.9.H.5 - If utilizing parking area access lanes (PAALs), they shall be designed in accordance with Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. 1. COMMENT: 2-06.4.9.H.5 – As stated in the OK to Submit review, the submitted plans do not meet UDC TSM 7-01.4.F. which states "Sidewalks or pedestrian refuge areas cannot be located between any motor vehicle parking space and the PAAL providing access to that space." Discussion with Stephen Blood and Elisa Hamblin in November 2025 confirmed that the proposed design does not meet the standard and will not be permitted. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, contact Site Zoning Reviewer Fernando Garcia at fernando.garcia2@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package and comment response letter. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/pdsd/website/Resubmittals.pdf. |
||
| 12/05/2025 | ROW Engineering Review Standard | REVIEW COMPLETED | Previous comments have been addressed. ROW permit required prior to working in the ROW |