Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TD-DEV-0823-00382
Parcel: 11206219B

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-0823-00382
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2024 CDRC Post Review Express PENDING ASSIGNMENT
12/13/2023 Commercial Plumbing REQUIRES RESUBMIT 1. Comment not addressed. [Initial comment: The rim elevation of the next upstream sanitary manhole (9810-95A1, 2411.66’) is higher than the first floor elevation (2408.50’). Provide a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson.]
2. Comment not addressed. [Initial comment: Provide a vent downstream of the gravity grease separator to protect the seal for the grease separator. Reference: Section 1003.9, IPC 2018.]
12/19/2023 ROW Engineering Review REQUIRES RESUBMIT DTMs response to these six TSMR requests.

1. TSMR UDC SECTION 7-01.3..3.B
a. DTM Approves this request.
2. TSM SECTION 10-01.9.0 FIGURE 6
a. DTM Approves this request. Curb returns are not required on Campbell Ave.
3. TSM SECTION 8-01.5.3.A
a. DTM has “No Comment” for this request.
4. TSM SECTION 7-01.4.1.G
a. DTM has “No Comment" for this request.
5. TSM SECTION 10-01.9.0 FIGURE 6
a. DTM requires a “Resubmit” for this request. Specific alternative to the 18’ radii is required.
6. TSM SECTION 7-04.6.F.2.a(2)
a. DTM has “No Comment" for this request.
01/03/2024 Site Engineering REQUIRES RESUBMIT 1. See TSMR Comments

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
12/21/2023 Site Landscape REQUIRES RESUBMIT See zoning comments.
12/12/2023 Site Zoning REQUIRES RESUBMIT CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Wyatt Berger
Lead Planner

PROJECT: New restaurant with drive-thru
Development Package (2nd Review)
TD-DEV-0823-00382

TRANSMITTAL DATE: December 12, 2023

DUE DATE: December 23, 2023

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC), Administrative Manual (AM) Section 2-06, and the Technical Standards Manual (TSM).

Per UDC Section 3.3.3.G.5.c, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. The new one year expiration date is December 12, 2024.

9. A revised plan set as well as a comment response letter were not submitted. Zoning acknowledges that an application for a Design Development Option (DDO) has been submitted to reduce the required side street perimeter yard. Per UDC 6.4.5.C.2.b, the required side street perimeter yard is 20'-0"; proposed is 18'-8".

If you have any questions about this transmittal, please contact me at Wyatt.Berger@tucsonaz.gov or at (520) 837-4951.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised development package as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf.
01/03/2024 TSMR/PDMR - Engineering REQUIRES RESUBMIT 1. TSMR 1 - Approved
2. TSMR 2 - No comment
3. TSMR 3 - Comments from Environmental Services: ES has no objections to being serviced off Copper St as this somewhat complies with TSM 8-01.9.0 figure 1. However, based on the angle of the enclosure in relation to the approach of the service vehicle it appears the truck may obstruct the entire street during service operation. Need to depict the 14’ x 40’ clear approach and call out the north border of Copper St. The enclosure may have to be rotated counter clockwise so at a 30 degree angle in order to minimize obstruction and satisfy access to enclosure.
4. TSMR 4 - The TSMR process can't eliminate the requirement for pedestrian circulation to the trash enclosure entirely. With pedestrian circulation being proposed and accepted to E Copper St via N Campbell Av, the required pedestrian circulation path to the trash enclosure could also be provided via N Campbell Av and shown as such on the plans to avoid crossing the drive thru lane.
5. TSMR 5 - No Comment
6. TSMR 6 - No Comment

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
01/04/2024 TSMR/PDMR - Zoning REQUIRES RESUBMIT See TSMR Engineering comments
12/20/2023 Zoning Modifications - DDO REQUIRES RESUBMIT FROM: Georgia Pennington, Planner
DATE: 12/20/23

COMMENTS:

1. Please resubmit DDO Description and Applicant's DDO request with accurate setback reduction request. The current request and plans do not match.

If you have questions, please contact me at Georgia.Pennington@tucsonaz.gov
11/22/2023 CDRC Application Completeness Express REVIEW COMPLETED