Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0823-00367
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/02/2023 | Commercial Plumbing | APPROVED | |||
| 09/19/2023 | Site Engineering | APPROVED | |||
| 08/30/2023 | Fire New Construction | NOT REQUIRED | |||
| 10/02/2023 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 09/27/2023 | ROW Engineering Review | REQUIRES RESUBMIT | TD-DEV-0823-00367 (2481 N FREMONT AV TUCSON, AZ 85719) Please resubmit revised drawings along with a detailed response letter which states how all comments were addressed. Comments: 1. TSM 10-01.4.1 Please build the new sidewalks in the ROW 5’ wide. 2. New driveway apron per P. A. G. SD 206. 3. Sidewalk that is crossed by a driveway should be 6” think. 4. It may be possible to lower the sidewalk for the apron crossing with a modified P. A. G. SD 207 Type 3 ramp. Email me for details. Otherwise, the sidewalk may meander behind the driveway apron. 5. Please add a curb ramp at the corner of E Water St. and N Fremont Av. per P. A. G. SD 207. 6. Please include the two utility poles in the drawing on the next submittal. The smaller pole may be scheduled for removal. Contact TEP for details. 7. TSM 10-01.3.3.D.1.d – Sidewalks may meander around utility poles to maintain 5’ sidewalk. Lateral transitions in sidewalk shall be 3:1. See P. A. G. SD 207 for an example. 8. A separate Right of Way General Permit is required for the work in the ROW. You can apply for this permit on TDC Online. Faffs Riederer Faffs.Riederer@tucsonaz.gov Abbreviations: City of Tucson Code (COTC), Unified Development Code (UDC) Administrative Manual (AM), Technical Standards Manual (TSM), Street Design Guide (SDG), Pima Association of Governments Standard Details (P. A. G. SD), Access Management Guidelines (AMG), Major Streets and Routes Plan (MS&R). |
||
| 09/28/2023 | Site Zoning | REQUIRES RESUBMIT | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Nathan Herrera Planner PROJECT: Development Package (1st Review) TD-DEV-0823-00367 TRANSMITTAL DATE: September 28, 2023 DUE DATE: September 30, 2023 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is August 20, 2024. 2-06.3.0 Format Requirements: 1. 2-06.3.4 - A title block shall be provided in the lower right quadrant of each sheet. COMMENT: Show correct Development Package #, TD-DEV-08723-00367, on 1st sheet. 2-06.4.0 Content Requirements: 2. 2-06.4.2 - The title block shall include the following information and be provided on each sheet: a. 2-06.4.2.B - A brief legal description b. 2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx). COMMENT: Provide a brief legal description and show “1 of 1” sheets per the above standards. 3. 2-06.4.4 - The project-location map to be located on the first sheet of the development package in the upper right corner, shall cover approximately one square mile, be drawn at a minimum scale of three-inch equals one mile, and provide the following information: a. 2-06.4.4.B - Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property. b. 2-06.4.4.C - Section, township, and range; section corners; north arrow; and the scale will be labeled. COMMENT: Remove the aerial from the location map (line work only). Identify the major streets (Grant Road, Mountain Ave, Park Ave). COMMENT: Identify section, township, range section corners on the location map. COMMENT: Minimum scale of three-inch equals one mile. 4. 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. COMMENT: Clarify General Note 10 to state the existing and proposed use of the property per the above standard. Per UDC Table 4.8-2, the current use is Residential-Single Family Attached, proposed use is Residential-Multifamily Development. List the associated Use Specific Standards for the proposed use (4.9.7.B.6, .9, & .10). 5. 2-06.4.7.A.8 - For development package documents provide: a. 2-06.4.7.A.8.c - Percentage of building, lot area, or vehicular use area expansion. If the building(s) or lot area have been previously expanded, those calculations shall be included. COMMENT: Break out the Lot Coverage calculation to show the percentage of each type of development that is contributing to the calculation. See UDC Article 6.4.3 for what types of development contribute to Lot Coverage. 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. a. 2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks. COMMENT: Add the above information to the Site Plan. 2-06.4.9.H Proposed Traffic Circulation 6. 2-06.4.9.H.5 - If utilizing parking area access lanes (PAALs), they shall be designed in accordance with Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. a. 2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. A typical parking space detail shall be provided. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. COMMENT: Provide dimensions for the proposed parking spaces per the above standard. COMMENT: Identify the EV Ready parking space. It appears that the EV Ready space is the easternmost parking space, but the keynote is labeled as “16” which is also long-term bicycle parking. COMMENT: Per UDC Table 7.4.4-1, one parking space per dwelling unit is required. Per UDC Article 6.6.3.b.2, the parking space requirement for the ADU can be waived due to the site being within ¼ mile walking distance of a transit stop. With the ADU parking waived a total of two parking are required, with one space required to be EV Ready. Change General Note 9.2 to reflect the correct parking calculation. COMMENT: Provide a dimension for the curb cut on Water St. Per UDC Table 7.4.6-2 a Two-Way PAAL must have a minimum width of 24 feet. COMMENT: Per UDC Article 7.4.6.H, “Barriers, such as post barricades or wheel stop curbing, are required in a vehicular use area to prevent vehicles from extending beyond the property lines , to prevent cars from damaging adjacent landscaping , walls, or buildings , overhanging adjacent sidewalk areas , and/or driving onto unimproved portions of the site.” Per the above requirement a barrier is required in the proposed vehicular use area. It appears that there is proposed curbing in the vehicular use area but is not identified. If there is curbing proposed call it out in the Keynotes and provide a dimension. COMMENT: Per UDC Article 7.4.6.F.4.c, “A minimum distance of three feet must be provided between the back of a back-up spur and any wall, screen, or other obstruction over six inches in height. Provide a dimension for the proposed back-up spur on the western portion of the site. The distance between the back-up spur and property line must meet the minimum required distance of 3 feet. COMMENT: Per UDC Article 7.4.6.H.1.a, demonstrate that the proposed sidewalk adjacent to the parking spaces can meet a minimum 4-foot width, when accounting for 2 ½ feet of vehicle overhang onto the sidewalk. If this requirement cannot be met, wheel stops will need to be placed 2 ½ feet back from the proposed sidewalk. b. 2-06.4.9.H.5.d - Show bicycle parking facilities fully dimensioned. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Provide, as a note, calculations for short and long-term bicycle spaces required and provided. COMMENT: Provide dimensions for the bicycle parking area on the Site Plan. 7. 2-06.4.9.O - All applicable building setback lines will be shown. COMMENT: Per UDC Table 6.3-2.A, the required setbacks for a nonresidential use adjacent to a residential zone are the greater of 10 feet or ¾ the height of the proposed exterior building wall. Change General Note 7.1 to reflect the required perimeter yard setbacks. Add the required setback dimensions to the Site Plan. COMMENT: Per UDC Article 6.4.5.C.2.b, “For multifamily development abutting a Local Street: the minimum required street perimeter yard is 20 feet, as measured from the street property line. Provide a dimension from the street property line on Water St to the proposed ADU. Provide a dimension from the street property line on Fremont Ave to the existing duplex. The proposed ADU will have to comply with the required street perimeter yard setback. 8. 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s). COMMENT: Provide the height of the existing and proposed structures per the above standard. 9. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. COMMENT: Per TSM Section 7-01.4.1.B. “A sidewalk is required adjacent and parallel to any access lane or PAAL on the side where buildings are located.” The proposed sidewalk must continue around the existing unit where the proposed parking spaces are and maintain a 4-foot width per TSM Section 4.3.A. COMMENT: Provide dimension for the proposed sidewalk on the Site Plan. 10. 2-06.4.9.S - Show existing or proposed pedestrian circulation along abutting rights-of-way. Such sidewalks must comply with accessibility requirements for the physically disabled and the design criteria in Section 10-01.0.0, Street Technical Standards, of the Technical Standards Manual. COMMENT: Per TSM Section 10-01.2.7.B., Sidewalks will be located a minimum of 2 feet from the back of the existing curb. Provide a dimension from the back of the existing curb on Water St. and Fremont Ave. to the proposed sidewalk to ensure compliance with this requirement. 11. 2-06.4.9.V - For gang mailboxes indicate location to assure there are no conflicts with other requirements, such as pedestrian accessibility, utilities, and landscaping. COMMENT: Aerial imagery shows existing mailboxes on Fremont Ave. Identify the mailboxes on the Site Plan, and any proposed additional mailboxes, or clarify if they are to be removed. If you have any questions about this transmittal, please contact me at Nathan.Herrera@tucsonaz.gov or at 520-837-4894. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised Development Package along with a detailed response letter, which states how all Zoning Review Section comments were addressed. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |
||
| 08/24/2023 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 08/29/2023 | CDRC Review Coordinator Express | REVIEW COMPLETED | No external reviewers, nor added. | ||
| 09/01/2023 | NPPO | REVIEW COMPLETED | |||
| 08/24/2023 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 08/24/2023 | OK to Submit - Landscape Fast | REVIEW COMPLETED | |||
| 08/24/2023 | OK to Submit - Zoning Fast | REVIEW COMPLETED | |||
| 09/01/2023 | Site Landscape | REVIEW COMPLETED |