Review Date Reviewer's Name Type of Review Description Status Comments
12/08/2023 ROW Engineering Review APPROVED
01/03/2024 Site Zoning APPROVED
01/03/2024 CDRC Post Review PENDING ASSIGNMENT
12/12/2023 Commercial Plumbing REQUIRES RESUBMIT Show the location of the backwater valve (Keynote 7) on the Utility sheet, C400. [Second comment: The MEP plans described in the response letter was not included in the latest submittal. Include the location of the backwater valve on sheet C400.] [Initial comment: The rim elevation of the next upstream sanitary manhole (8144-09, 2516.47’) is higher than the first floor elevation (2515.85). Provide a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson.]
11/30/2023 CDRC Application Completeness REVIEW COMPLETED