Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.3
Permit Number - TD-DEV-0823-00364
Review Name: DEVELOPMENT PACKAGE NEW v.3
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/08/2023 | ROW Engineering Review | APPROVED | |||
01/03/2024 | Site Zoning | APPROVED | |||
01/03/2024 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
12/12/2023 | Commercial Plumbing | REQUIRES RESUBMIT | Show the location of the backwater valve (Keynote 7) on the Utility sheet, C400. [Second comment: The MEP plans described in the response letter was not included in the latest submittal. Include the location of the backwater valve on sheet C400.] [Initial comment: The rim elevation of the next upstream sanitary manhole (8144-09, 2516.47’) is higher than the first floor elevation (2515.85). Provide a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson.] | ||
11/30/2023 | CDRC Application Completeness Express | REVIEW COMPLETED |