Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0726-00202
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/29/2026 | CDRC Review Coordinator Express | PENDING ASSIGNMENT | |||
| 07/29/2026 | Commercial Plumbing Standard | PENDING ASSIGNMENT | |||
| 07/29/2026 | Fire New Construction Standard | PENDING ASSIGNMENT | |||
| 07/29/2026 | NPPO Standard | PENDING ASSIGNMENT | |||
| 07/29/2026 | ROW Engineering Review Standard | PENDING ASSIGNMENT | |||
| 07/29/2026 | ROW Review | PENDING ASSIGNMENT | |||
| 07/29/2026 | Site Engineering Standard | PENDING ASSIGNMENT | |||
| 07/29/2026 | Site Landscape Standard | PENDING ASSIGNMENT | |||
| 07/29/2026 | Site Zoning Standard | PENDING ASSIGNMENT | |||
| 07/27/2026 | OK to Submit - Engineering Fast | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0726-00202 (OK To Submit Review) Project: Renovation of an Existing Walmart - Installation of EV Parking Spaces, adjustments to parking area, & updates to pedestrian circulation Location: 1650 W VALENCIA RD Review Date: 7/27/2026 Reviewer: Marco Contreras – Engineering Associate Reviewer Contact Information: marco.contreras@tucsonaz.gov Related cases: Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards. The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files. Applicable Code Links for quick/direct reference: City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf City of Tucson Chapter 25: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-18593 Site Engineering Application Completeness Review Comments: NOTICE: This is a completeness check review performed by both Site Engineering & Zoning to determine whether the submission in question is sufficient for full review by all applicable reviewing parties. As such, do not interpret the provided comments as finalized complete review comments. They are simply to address outstanding issues caught at this stage of submission. 1. Application incomplete, please provide the following for resubmission: a. Provide an earthwork table that provides: preferably on the cover sheet i. Cut & Fill quantities associated with the proposed grading & construction ii. Total area of disturbance in both square footage & acres. b. The provided submission provides two files – The site plan sheets and the grading plan sheets. Both these plan sets should be revised to function under one plan file with applicable formatting and content requirements as found under AM 2-06.4.7.0. At a minimum before full review, please consolidate and format both files to be one plan set. |
||
| 07/29/2026 | OK to Submit - Zoning Fast | REQUIRES RESUBMIT | 1. COMMENT: In the parking calculation, please include the calculation demonstrating the minimum required parking spaces. The minimum parking ratio is 1 space to 300 square feet of gross floor area. 2. COMMENT: The parking information should include the parking calculations for the entire shopping center. 3. COMMENT: Include the development package case number in the bottom right corner, TD-DEV-0726-00202, adjacent to the title block. 4. COMMENT: Include a General Note stating the existing and proposed zone is C-2. 5. COMMENT: Include a General Note stating the existing and proposed use is Retail - Large Retail Establishment subject to UDC 4.9.9.D. 6. COMMENT: Address Site Engineering comments. Loran Shamis loran.shamis@tucsonaz.gov |
||
| 07/27/2026 | CDRC Application Completeness Express | REVIEW COMPLETED |