Permit Review Detail
Review Status: In Review
Review Details: DEVELOPMENT PACKAGE NEW v.2
Permit Number - TD-DEV-0726-00196
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/19/2026 | External Reviewers - Pima County Addressing Standard | APPROVED | Good morning, Pima County Addressing approves TD-DEV-0726-00196. Thank you, David Wilging Planner I - Addressing Division Pima County Development Services 201 N. Stone Avenue 1st Floor Tucson, Arizona 85701 520-724-6381 |
||
| N/A | External Reviewers - Arizona Department of Transportation (ADOT) Standard | PENDING ASSIGNMENT | |||
| N/A | External Reviewers - Tucson Airport Authority Standard | PENDING ASSIGNMENT | |||
| N/A | Fire New Construction Standard | PENDING ASSIGNMENT | |||
| N/A | NPPO Standard | PENDING ASSIGNMENT | |||
| N/A | ROW Engineering Review Standard | PENDING ASSIGNMENT | |||
| N/A | ROW Review | PENDING ASSIGNMENT | |||
| N/A | Site Engineering Standard | PENDING ASSIGNMENT | |||
| N/A | Site Landscape Standard | PENDING ASSIGNMENT | |||
| N/A | Site Zoning Standard | PENDING ASSIGNMENT | |||
| 08/20/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | ACTIVITY NO. TD-DEV-0726-00196 ADDRESS/PARCEL: 5030 E VALENCIA RD TUCSON, AZ 85756 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov. COMMENTS: 1. Cleanouts shall allow the drainage piping to be cleaned only in the direction of flow. Two additional two-way cleanouts are shown on Sheet C4.1, aside from the cleanout at the building junction/building sewer. Please clarify. Reference: Section 708.1.9, IPC 2024. 2. Please show the RIM elevation of the nearest upstream manhole on the plans to determine whether a backwater valve is required. The topographic survey included with the associated building plans (TC-COM-0626-00992) shows the RIM elevation as 2690.36. Please include this information on this DP. Reference: Section 714.1, IPC 2024, as amended by the City of Tucson. |
||
| 08/18/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added Addressing, ADOT, TAA, PAG, USPS, SWG, and TEP to the workflow. FYI notice sent to PAG, USPS, SWG, and TEP | ||
| 08/18/2026 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 08/18/2026 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 08/18/2026 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 08/18/2026 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 08/14/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED |