Permit Review Detail
Review Status: In Review
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0726-00195
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | NPPO Standard | PENDING ASSIGNMENT | |||
| N/A | ROW Engineering Review Standard | PENDING ASSIGNMENT | |||
| N/A | Site Landscape Standard | PENDING ASSIGNMENT | |||
| 08/18/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0726-00195 (1st Review) Project: Prime Leaf Drive Thru Location: 1525 N PARK AV Review Date: 8/18/2026 Reviewer: Joe Macaulay – Civil Engineer – Site Development Reviewer Contact Information: joe.macaulay@tucsonaz.gov Related cases: TC-COM-0826-01275, TC-UTL-0726-00116 Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards. The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files. Applicable Code Links for quick/direct reference: City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf City of Tucson Chapter 25: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-18593 Site Engineering Review Comments: 1. Provide the development package case number, TD-DEV-0726-00195, adjacent to the title block on all sheets. |
||
| 08/19/2026 | Site Zoning Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Loran Shamis, Principal Planner PDSD Zoning Review Section PROJECT: Retrofit of existing VUA into a drive-thru lane at Prime Leaf Dispensary Development Package (1st Review) TD-DEV-0726-00195 (1525 N Park Av) COMMENTS: 1. COMMENT: Include the Development Package case number, TD-DEV-0726-00195, and the approved Zoning Examiner Special Exception Procedure case number, TP-ENT-0326-00006, in the bottom right corner on each sheet of the plan set, adjacent to the title block. 2. COMMENT: The proposed development does not comply with UDC 7.4.6.E.2, which requires a minimum height clearance of 15 feet along access lanes and PAALs. Zoning acknowledges that the applicant has submitted a Parking Design Modification Request (PDMR) to reduce the required height clearance; however, pursuant to UDC 7.4.10.D.7, a PDMR may modify a dimensional standard by no more than 10%. The proposed 9-foot clearance exceeds the allowable 10% reduction. A 10% reduction would allow the required clearance to be reduced from 15 feet to 13.5 feet. Zoning cannot approve the proposal until the plan set demonstrates compliance with the required 15-foot clearance or an approved PDMR consistent with the proposed clearance is provided. If you have any questions about this transmittal, contact Loran Shamis any time during the week at (520) 837-2242 or Loran.shamis@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
||
| 08/06/2026 | TSMR/PDMR - Engineering | REQUIRES RESUBMIT | 1. See Zoning Comment Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
||
| 08/05/2026 | TSMR/PDMR - Zoning | REQUIRES RESUBMIT | UDC Section 7.4.10.D.7 - a PDMR may modify a dimensional requirement by no more than 10%. | ||
| 07/17/2026 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 07/29/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added PAG, USPS, SWG, and TEP to the workflow. Fyi notice sent to PAG, USPS, SWG, and TEP. | ||
| 08/14/2026 | Commercial Plumbing Standard | REVIEW COMPLETED | |||
| 07/29/2026 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 07/29/2026 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 07/29/2026 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 07/29/2026 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 08/18/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 07/17/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 07/21/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED |