Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0726-00187
Parcel: 112072400

Address:
2750 N TUCSON BL

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-0726-00187
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/13/2026 NPPO Standard NOT REQUIRED
08/13/2026 Site Landscape Standard NOT REQUIRED
08/10/2026 Fire New Construction Standard REQUIRES RESUBMIT -Knox key boxes required for the gates. Provide notes on the drawings.
john.vincent@tucsonaz.gov
5203495581
08/03/2026 Site Engineering Standard REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0726-00187 (1st Review)
Project: THIS PROJECT IS A TENANT IMPROVEMENT THAT CONSISTS OF INSTALLING A FENCE AND TWO GATES AS NECESSARY TO KEEP THE CHILDREN IN A SAFE ENVIRONMENT.
Location: 2750 N TUCSON BL
Review Date: 8/3/2026
Reviewer: Marco Contreras – Engineering Associate & Joe Macaulay – Civil Engineer
Reviewer Contact Information: marco.contreras@tucsonaz.gov
Related cases:

Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards.
The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files.

Applicable Code Links for quick/direct reference:
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf
City of Tucson Chapter 25: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-18593

Site Engineering Review Comments:
1. Provide the development package case number (TD-DEV-0726-00187) adjacent to the title block on each sheet of the plan set. [AM 2-06.3.3]
2. Provide the Zoning and Land Use General note: “The developer, any successors and assigns, will hold the City of Tucson, its officers, employees, and agents harmless from any and all claims for damages related to the use of this development as shown hereon, now and in the future, by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall.” [AM 2-06.4.7.B.1]
3. Clarification required – will this open area enclosed by the fencing and gates ever be used by vehicles or require vehicle access?
a. If the gates shown are intended to be vehicle gates, Revise the site plan provided to provide compliant Sight visibility triangles for the site entrance: Tucson BLVD is designated as a Collector Road. This designation will be used for Table 5.3. Refer to TSM 10-01.9.0 Figures 16-18 for examples of SVTs. [TSM 10-01.5.0.]
b. Confirm that no proposed structures, walls, signs, landscaping, or other vertical elements exceeding the allowable height limit encroach within the established SVT at any site access point
c. If Vehicles will be used within this area, surfacing requirements may need to be addressed per UDC 7.4.6.I.
4. As the subject property/site is located within a locally mapped floodplain with associated regulatory limits of Treat Avenue FP – a floodplain use (FPU) permit application will be administratively begun and processed for the development to assure compliance with establish floodplain regulations and standards. No further action is required for this comment.
5. With review of aerial imagery and applicable code violations – it will be required that the submitted plans be revised to provide the applicable information:
a. Provide sufficient spot elevations – they should show existing vs. proposed (New) elevations
b. Show limits of the grading work disturbance
c. Total cut & fill quantities with applicable total area of disturbance in SQ FT & Acres
6. Provide a note with the fence detail that states: “The bottom 6-inches from natural/finished grade and up shall remain free and clear of obstruction to allow for the conveyance of flood waters.
7. As Tucson BLVD is a designated Major Street & Route – it will be required that vehicle maneuverability be demonstrated. Revise the plans to properly delineate both the property line vs ROW along the Western frontage.
08/11/2026 Site Zoning Standard REQUIRES RESUBMIT CDRC TRANSMITTAL

REVIEWED BY: Krista Hansen – Lead Planner
PDSD Zoning Review Section

PROJECT: The Drawing Studio
Development Package (1st Review)
TD-DEV-0726-00187 (2750 N TUCSON BL)

TRANSMITTAL DATE: 8/11/2026

Per UDC Section 3.3.3.G.5.c, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year expiration date is July 12, 2027.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)


2-06.4 CONTENT REQUIREMENTS

4.1.B.6 The administrative street address and relevant case numbers (DP, subdivision, rezoning, BOA, DDO, PDMR, TSMR, overlay, etc.).

1. COMMENT: 2-06.4.1.B.6 – Provide the development package case number, TD-DEV-0726-00187, adjacent to the title block on each sheet.


4.2.A. List as a note: “Existing zoning is ____.”

2. COMMENT: 2-06.4.2.A – The zoning classification is C-1. Please correct under “Project Site and Data.”


4.2.D. Identify the existing and proposed use of the property as classified per the UDC. Reference all UDC use-specific standards applicable to the proposed uses.

3. COMMENT: 2-06.4.2.D – Under “Project Site and Data,” add the existing and proposed Use, which is “Educational Use – Instructional School, subject to UDC Use Specific Standards 4.9.13.O.”


4.3.A List the following notes on all plans/plats: “The developer, any successors and assigns, will hold the City of Tucson, its officers, employees, and agents harmless from any and all claims for damages related to the use of this development as shown hereon, now and in the future, by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall.”

4. COMMENT: 2-06.4.3.A – Under “Drainage Notes,” add the note listed in the standard above.


4.7.A Provide site boundary/subdivision perimeter information, including bearing in degrees, minutes, and seconds, with basis for bearing noted, together with distances in feet, to hundredths of a foot, or other functional reference system.

5. COMMENT: 2-06.4.7.A – Provide the information listed in the standard above.


4.7.F Indicate all existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) on the drawing with zoning boundaries clearly defined.

6. COMMENT: 2-06.4.7.F – On the site plan, add the adjacent zoning classifications, which are: O-3 to the west, C-1 to the north and east, and R-2 to the south.


4.7.H Illustrate all buildings and provide the square footage, the height, the proposed use, and the number of units (if applicable) within the footprint of each building(s).

7. COMMENT: 2-06.4.7.H – On the site plan, provide the information listed in the standard above. The Lot coverage calculations include a 2,720 sq ft dwelling. Clarify where this structure is on the site.


4.7.V.1 Indicate if streets within or adjacent to the site are public or private, the street names, recordation type, utility locations, and fully dimensioned widths, curbs, and sidewalks.

8. COMMENT: 2-06.4.7.V.1 – Label N Tucson Boulevard as a Major Street and Route, Collector. Dimension the right-of-way width.


9. COMMENT: The Assessor Record Map shows a 20 ft alley south of the parcel. On the site plan, dimension the alley from the property line, not from the building.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please resubmit revised drawings and any corrected plans along with a detailed response letter, stating how all Site Zoning Review comments were addressed.

**Instructions for resubmittal - www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf.

***For additional information on the standards presented in this memo, please refer to the City of Tucson Administrative Manual Section 2-06 or Technical Standards noted in the comments.

If you have any questions about this transmittal, please contact Krista Hansen at krista.hansen@tucsonaz.gov
07/15/2026 CDRC Application Completeness Express REVIEW COMPLETED
07/20/2026 CDRC Review Coordinator Express REVIEW COMPLETED CDRC added TEP, SWG, PAG, USPS, and addressing to workflow. FYI sent to TEP, PAG, SWG, USPS.
08/07/2026 Commercial Plumbing Standard REVIEW COMPLETED
07/20/2026 External Reviewers - Pima Association of Governments Standard REVIEW COMPLETED CDRC sent FYI Notice email sent. No further action is required.
07/21/2026 External Reviewers - Pima County Addressing Standard REVIEW COMPLETED Good morning,

TD-DEV-0726-00187 does not require review from Pima County Addressing.



Thank you,







David Wilging

Planner I - Addressing Division

Pima County Development Services

201 N. Stone Avenue 1st Floor

Tucson, Arizona 85701

520-724-6381
07/20/2026 External Reviewers - Southwest Gas Standard REVIEW COMPLETED CDRC sent FYI Notice email sent. No further action is required.
07/20/2026 External Reviewers - Tucson Electric Power (TEP) Standard REVIEW COMPLETED CDRC sent FYI Notice email sent. No further action is required.
07/20/2026 External Reviewers - United States Postal Service (USPS) Standard REVIEW COMPLETED CDRC sent FYI Notice email sent. No further action is required.
07/15/2026 OK to Submit - Engineering Fast REVIEW COMPLETED
07/17/2026 OK to Submit - Zoning Fast REVIEW COMPLETED
08/04/2026 ROW Engineering Review Standard REVIEW COMPLETED Gated entrances may be allowed for commercial developments, Stopping locations for keypads, card-readers, guard shacks, etc. shall be set back from the right-of-way
of the cross street to avoid interfering with through traffic and to provide protection for entering vehicles. The gate may not encroach into the public right-of-way or any travel lane when open. The design of the entrance shall allow vehicles that do not go past the gate to turn around without interfering with other traffic. The turnaround area shall be located within the development boundary outside of the local street,
collector, or arterial right-of-way. Show sight visibility triangles for driveways.