Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.2
Permit Number - TD-DEV-0726-00178
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/25/2026 | NPPO Standard | APPROVED | |||
| 09/24/2026 | Site Engineering Standard | APPROVED | |||
| 09/25/2026 | Site Landscape Standard | APPROVED | |||
| 09/10/2026 | Site Zoning Standard | APPROVED | |||
| 09/24/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | ACTIVITY NO. TD-DEV-0726-00178 ADDRESS/PARCEL: 4214 N 1ST AV TUCSON, AZ 85719 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov. COMMENTS: 1. A backwater valve is not required. The RIM elevation of the nearest upstream manhole is 2326.1 and the FFE is 2327.50. Since the FFE is more than 12 inches above the elevation of the next upstream manhole, a backwater valve is not required. Reference: Section 714.1, IPC 2024, as amended by the City of Tucson. 2. The FFE on Sheet 5 shows 2327.56, but the FEE on Sheet 6 shows 2327.50. Please revise for consistency. |