Review Date Reviewer's Name Type of Review Description Status Comments
09/25/2026 NPPO Standard APPROVED
09/24/2026 Site Engineering Standard APPROVED
09/25/2026 Site Landscape Standard APPROVED
09/10/2026 Site Zoning Standard APPROVED
09/24/2026 Commercial Plumbing Standard REQUIRES RESUBMIT ACTIVITY NO. TD-DEV-0726-00178
ADDRESS/PARCEL: 4214 N 1ST AV TUCSON, AZ 85719

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. A backwater valve is not required. The RIM elevation of the nearest upstream manhole is 2326.1 and the FFE is 2327.50. Since the FFE is more than 12 inches above the elevation of the next upstream manhole, a backwater valve is not required. Reference: Section 714.1, IPC 2024, as amended by the City of Tucson.
2. The FFE on Sheet 5 shows 2327.56, but the FEE on Sheet 6 shows 2327.50. Please revise for consistency.