Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TD-DEV-0725-00196
Parcel: 12215407B

Address:
3453 E PIMA ST

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-0725-00196
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/03/2025 NPPO Standard APPROVED A NPPP for the existing Saguaro is not require for this new wall due to the this parcel is part of a platted and recorded subdivision from 1919. Please preserve and protect the Saguaro in place. Provide protective construction fencing around the Saguaro.

Thank you.
Chad Keller, RLA
chad.keller@tucsonaz.gov
09/29/2025 Fire New Construction Standard NOT REQUIRED
10/03/2025 Site Landscape Standard NOT REQUIRED
01/20/2026 Floodplain Administration Review Standard REQUIRES RESUBMIT Previously, a phone call was made to the engineer discussing the adverse impact potential. See the following comments discussed:
1) Proposed perimeter wall can only be accepted with wall openings that provide 100-year conveyance. If wall is still proposed for resubmittal, show wall openings and provide calculations that show that the existing depth of regulatory flood elevation is accommodated.
2) Proposed southwest perimeter berm is not approved as this could deflect flood waters toward house.
3) Pump (with secondary pump) should be used as a cautionary measure as pumps typically fail during flood events.
4) Interceptor swales are acceptable.
5) Alternatives (not required but could be considered) for flood proofing include: hiring a special environmental engineer to assess conditions and provide specialized design that may include floodproofed doors, floodproofing treatment to lower portion of structure to provide wet-proofing, and other designs.
6) Berming and walls located close (a few feet) to the structure may be considered, however perimeter walls and berms cause diversion and/or obstruction of floodwaters to neighbouring private and public infrastructure which increases potential flood hazards and liability due to the adverse impacts.
Call me at 520-429-4905 to discuss.
Elizabeth Eberbach P.E., CPM. CFM
Civil Engineer
City of Tucson
520-429-4905
elizabeth.eberbach@tucsonaz.gov
09/22/2025 ROW Engineering Review Standard REQUIRES RESUBMIT Show ROW lines and property lines. block walk wall should not exceed 30" height in Sight-Visibility-Triangle
10/06/2025 Site Engineering Standard REQUIRES RESUBMIT TD-DEV-0725-00196
3453 E PIMA ST

Site Engineering Comments:

1. This project requires that a Hydrology Roport be submitted because the flows in the area are in excess of 100-cfs. This report shall include encroachment analysis for the neighboring parcels.
2. Earthen berms / levees are permitted as long as there are no adverse impacts to the neighboring properties.
3. Some of the parking may be relocated to the north side of the property and accessed via the adjacent north/south alleyway.
4. The proposed speedbump will be permitted.
5. See Section 4.18 of the Design Standards for Stormwater Detention and Retention Manual for requirements regarding the proposed sump pump. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf
6. The proposed wall may be permitted as long as it does not cause adverse effects to the neighboring properties. If it is extended toward the southern property line, please abide by the sight visibility requirements of TSM 10-01.5. https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-12456

Ryan Insalaco
Engineering Associate
ryan.insalaco@tucsonaz.gov
10/13/2025 Site Zoning Standard REQUIRES RESUBMIT CDRC TRANSMITTAL

FROM:
Bobby Parsons
PDSD Zoning Review Section

PROJECT:
3453 E. Pima Street Tucson, AZ 85716
Development Package (1st Review)
TD-DEV-0725-00196

TRANSMITTAL DATE: 10/13/2025
DUE DATE: 10/2/2025

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is September 9, 2026.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)

CONTENT REQUIREMENTS

2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet.

1. COMMENT: 2-06.4.3 - Provide the development package case number, TD-DEV-0725-00196, adjacent to the title block on each sheet.

2. COMMENT: Per discussions with Site Zoning Lead Planner, please address Right of Way Engineering and Site Engineering comments. Site zoning will review the revised plans and will have additional comments if the required parking or other site requirements need to be altered due to the remediation.

***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations

If you have any questions about this transmittal, Contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package and comment response letter. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home.
Instructions for resubmittal - https://www.tucsonaz.gov/files/pdsd/website/Resubmittals.pdf.
09/04/2025 CDRC Application Completeness Express REVIEW COMPLETED
09/11/2025 CDRC Review Coordinator Express REVIEW COMPLETED FYI
CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
09/30/2025 Commercial Plumbing Standard REVIEW COMPLETED
09/11/2025 External Reviewers - Pima Association of Governments Standard REVIEW COMPLETED FYI
CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
09/11/2025 External Reviewers - Southwest Gas Standard REVIEW COMPLETED FYI
CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
09/11/2025 External Reviewers - United States Postal Service (USPS) Standard REVIEW COMPLETED FYI
CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
09/05/2025 OK to Submit - Engineering Fast REVIEW COMPLETED
09/10/2025 OK to Submit - Zoning Fast REVIEW COMPLETED