Permit Number: TD-DEV-0725-00190
Parcel: 106022290

Address:
321 W PASTIME RD

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-0725-00190
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/11/2025 Fire New Construction Standard REQUIRES RESUBMIT -Add fire dept no parking signs to the south end and west end of the "hammerhead." You can find the sign details on our amendments. No parking signs also required on the street serving the residences.
john.vincent@tucsonaz.gov
5203495581
08/15/2025 NPPO Standard REQUIRES RESUBMIT See site landscape comments for NPPO requirements.

Thank you.
Chad Keller, RLA
chad.keller@tucsonaz.gov
07/31/2025 ROW Engineering Review Standard REQUIRES RESUBMIT TD-DEV-0725-00190 • 321 W PASTIME RD

1. Per Sec. 10-01.4.4.F of the UDC Technical Standards Manual the 10yr flood discharge from Basin 2 will have to be directed under the sidewalk along Pastime Rd.

If you have any questions on these comments, please contact Richard Leigh at 520-403-0970 or at richard.leigh@tucsonaz.gov.
08/18/2025 Site Engineering Standard REQUIRES RESUBMIT Permit: TD-DEV-0725-00190
Location: 321 W PASTIME RD
Review Date: 8/18/2025
Site Engineering Comments:
1. Dimension the basins on the grading/plan sheets
2. Show more spot elevations and flow arrows to verify flow patterns on the grading sheet
3. The site is not located with a FEMA or COT floodplain, Revise Note 25 and 26 from the General Notes to be consistent with the drainage report.
4. Show the main SFR square footage for each lot
5. Basin 2 outlet will have to direct the 10yr flood discharge under the sidewalk along Pastime Rd.
6. Show the 2ft minimum grading setback from the property line for the basins on the grading and site plan TSM 2-01.9.0
7. Structures must be setback at least 15 feet from a basin Drainage Manual 4.14.1.2, ensure to delineate these setbacks on the plans as required by Administrative Manual 2-06.4.9.O
8. Maintenance access for the detention/water harvesting basins must be shown and described in the drainage statement.
9. Show vertical separation between the proposed shared driveway and the basins.
10. Show Sight Visibility Triangles for driveways along Pastime Rd

If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
08/15/2025 Site Landscape Standard REQUIRES RESUBMIT CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: 5 LOT RESIDENTIAL SUBDIVISION
ACTIVITY NO: TD-DEV-0725-00190
ADDRESS: 321 W PASTIME RD
ZONING: R-2 RESIDENCE ZONE
LAND USE: RESIDENTIAL SUBDIVISION

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting.

Please resubmit revised drawings along with a detailed response letter, which states how all of the Site Landscape and NPPO Section review comments have been addressed.

SITE LANDSCAPE/NPPO SECTION COMMENTS:

1. PRE-APPLICATION COMMENT ADDRESSED: Provide a NPPO or a NPPO waiver for the trees that will be removed due to the development of the duplexes on each lot. See UDC 7.7. SEE UDC 7.7.3. APPLICABILITY; UDC 7.7.4 NPPO GENERAL PROVISIONS AND STANDARDS; UDC 7.7.4.C. PLAN APPROVAL PRIOR TO PERMITTING; UDC 7.7.4.D. PROFESSIONAL EXPERTISE 7.7.5.C.5; ALSO SEE AM 2-11.3.0 PERMITTED EXCEPTIONS. PDSD will provide the applicant with the NPPO Waiver form upon request.

2. PRE-APPLICATION COMMMENT ADDRESSED/NA: If any parking areas contain 4 or more parking spaces, then the following will be required: 1 tree to every 4 parking spaces per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.

3. PRE-APPLICATION COMMMENT ADDRESSED: If tress are required due to the above-mentioned standard, then a landscape plan set will be required. The landscape plan set will include a planting and an irrigation plan as well as applicable planting and irrigation details.

4. Provide the contact information for the NPPO monitor.

5. For the preserve in place protected native plants provide the native plant preservation fence detail as stated in note number one on the NPPO sheet.

6. Provide the development package case number, TD-DEV-0725-00190, adjacent to the title block on all site landscape sheets, per Administrative Manual 2-06.4.3

Thank you.
Chad Keller, RLA
Landscape Architect
chad.keller@tucsonaz.gov
520.837.4923
08/18/2025 Site Zoning Standard REQUIRES RESUBMIT CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Krista Hansen – Lead Planner
PDSD Zoning Review Section

PROJECT: Pastime Flats Subdivision – Subdivision
Development Package (1st Review)
TD-DEV-0725-00190
321 W PASTIME RD – R-2

TRANSMITTAL DATE: August 18, 2025


COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is July 21, 2026.


SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)


1. COMMENT: Per Unified Development Code (UDC) Section 6.6.3.B.5., “an ADU is limited to 75% of the gross floor area (GFA) of the principal dwelling.” The ADUs proposed on Lots 1 – 5 exceed 75% of the GFA of the principal dwelling, and therefore, are all considered a second single-family residence (SRF).

The R-2 zone allows 15 units per acre (2,904 sq ft per unit). A minimum of 5,808 sq ft is required for two SFR units on one lot. Lots 2, 4, and 5 do not meet the minimum lot size for two SFRs. Either modify size of ADUs or adjust lot lines to meet the requirements.

2. COMMENT: Draw and dimension setbacks from all existing and proposed structures to all applicable lot lines. To confirm setbacks, provide the wall height of each structure within the footprint of the building(s).


CONTENT REQUIREMENTS


2-06.4.2 - The title block shall include the following information and be provided on each sheet:

2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet.

3. COMMENT: Provide the development package case number, TD-DEV-0725-00190, adjacent to the title block on each sheet.


2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses.

4. COMMENT: The proposed use is listed as a “Single-Family Subdivision.” Currently the proposed lots function as one site due to the potential for shared access and/or parking. Demonstrate how all five lots will function separately and independently of each other; otherwise, this could be considered one multi-family development and potentially be subject to full commercial development standards.


2-06.4.7.A.6 - If a plan or plat is prepared in conjunction with other applications or overlays or the parcel being developed is subject to conditions of an application processed previously, additional information must be added to the plan.

5. COMMENT: This site is not located in an overlay zone or along a Major Street and Route. Remove Note 24 from General Notes.


2-06.4.7.A.8 - For development package documents provide:

2-06.4.7.A.8.a - Floor area for each building;

6. COMMENT: On the site plan, add the floor area of each main residence within the footprint of the structure.


2-06.4.7.A.8.b - Percentage and area in square feet of building and accessory building coverage;

7. COMMENT: Provide the information as stated in the standard above.


2-06.4.9.H - Proposed Traffic Circulation

2-06.4.9.H.1 - Proposed traffic circulation will be designed in accordance with Section 10-01.0.0, Street Technical Standards, of the Technical Standards Manual, to include streets, intersections, street names, right-of-way widths, curve radii of centerlines and curb returns, and proposed improvements, such as pavement, curbs, access points (driveways), accessible ramps, and sidewalks. Street improvements, such as sidewalks, curbs, pavement, and accessible ramps, do not need to be drawn on the plan if such information is provided on typical street cross sections.

2-06.4.9.H.2 - Show future and existing sight visibility triangles (STV). On a designated MS&R street, the sight visibility triangles are based on the MS&R cross-section.

8. COMMENT: Show SVTs for driveways along Pastime Rd.


2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual.

9. COMMENT: Per the City of Tucson Inclusive Home Design Ordinance (https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf), all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route to each individual unit from the sidewalk or private street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards (https://www.access-board.gov/ada/chapter/ch04/). See TSM 7-01.4.3 for specifications, including slope and composition materials.


***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations

If you have any questions about this transmittal, Contact Krista Hansen by email Krista.hansen@tucsonaz.gov
07/21/2025 CDRC Application Completeness Express REVIEW COMPLETED
07/24/2025 CDRC Review Coordinator Express REVIEW COMPLETED EXTERNAL REVIEWERS
CDRC added ASSESORS, ADRESSING, ADOT and TEP, SWG USPS, and PAG to the workflow. Review request email sent to ADRESSING, ADOT and TEP. FYI email sent to, SWG USPS PAG.
08/14/2025 Commercial Plumbing Standard REVIEW COMPLETED
08/05/2025 External Reviewers - Arizona Department of Transportation (ADOT) Standard REVIEW COMPLETED jgomes@azdot.gov
on behalf of
ADOT SC Traffic Engineering - ADOT
​CDRC​
Good Afternoon,

ADOT has no comments on this DEV.

Thank you for the opportunity to review.
07/24/2025 External Reviewers - Pima Association of Governments Standard REVIEW COMPLETED FYI
CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
08/19/2025 External Reviewers - Pima County Addressing Standard REVIEW COMPLETED Good evening,

Pima County Addressing approves TD-DEV-0725-00190.

Nicholas Jordan

Site Review Project Manager II – Addressing Official

Pima County Development Services Department

201 N Stone AV – 1st Floor

Tucson, AZ 85701

(520) 724-9623
07/24/2025 External Reviewers - Southwest Gas Standard REVIEW COMPLETED FYI
CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
08/21/2025 External Reviewers - Tucson Electric Power (TEP) Standard REVIEW COMPLETED 4350 E. Irvington Road
Post Office Box 711, Tucson, AZ 85702
August 21, 2025
WO#T158307
City of Tucson
Planning and Development Services
Attn: CDRC Admin Team
Dear CDRC Admin Team
Subject: Pastime Flats, Lots 1-5
TD-DEV-0725-00190
Tucson Electric Power Company (TEP) has reviewed and approved the development
plan submitted 7/24/2025. There are no existing facilities within the development. There
are no apparent conflicts at this time.
Enclosed is a copy of a TEP facilities map showing the approximate location of the
existing facilities. Any relocation costs will be billable to the customer.
To apply for electric service, please call the New Construction department at (520) 918-
8300. Please submit a final set of plans including approved site, electric load, paving
off-site improvements and irrigation plans. If available, include a PDF version of the
plans.
If easements are required, they will be secured by separate instrument. Should you
have any easement questions, please contact our Land Resources Department,
LandReviews@tep.com.
Should you have any technical questions, please contact the area designer,
Chuck Leon
(520) 235-6329
fquintero@tep.com
Sincerely,
Design Admins
Design Admins
Tucson Electric Power
07/24/2025 External Reviewers - United States Postal Service (USPS) Standard REVIEW COMPLETED FYI
CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
07/23/2025 OK to Submit - Engineering Fast REVIEW COMPLETED
07/23/2025 OK to Submit - Zoning Fast REVIEW COMPLETED