| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/18/2025 | NPPO Standard | APPROVED | |||
| 08/12/2025 | Site Zoning Standard | APPROVED | |||
| 08/14/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TD-DEV-0725-00188 Location: 10910 E ESCALANTE RD Review Date: 8/14/2025 Site Engineering Comments: 1. Show vertical transition for driveway to show travelability 2. Per the City of Tucson Inclusive Home Design Ordinance (https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf), all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards (https://www.access-board.gov/ada/chapter/ch04/). See TSM 7-01.4.3 for specifications, including slope and composition materials. 3. If by virtue of terrain or other unusual characteristics of the building site, there are practical difficulties associated with compliance, a request to waive this requirement may be submitted through Tucson Development Center Online. Select “Building Official Appeal” as from the “Sub-Records” tab of this permit to apply. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 08/18/2025 | Site Landscape Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: SINGLE FAMILY RESIDENCE ACTIVITY NO: TD-DEV-0725-00188 ADDRESS: 10910 E ESCALANTE RD ZONING: SR SUBURBAN RANCH ZONE This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all of the Site Landscape and NPPO Section review comments have been addressed. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. Provide the development package case number, TD-DEV-0725-00188, adjacent to the title block on all site landscape sheets, per Administrative Manual 2-06.4.3 Add the HDZ notes below to your site plan. 2. HILLSIDE DEVELOPMENT ZONE (HDZ), UDC 5.2. ADD THE FOLLOWING NOTES TO THE SITE PLAN. Vegetation Retention and Revegetation a. Vegetation Retention (1) Existing viable and transplantable trees with four inch or greater trunk diameter and cacti shall be preserved in their original locations, except for building sites and access and utilities serving building sites. (2) When retention of the above trees and cacti in their original locations is not possible due to building site location, the trees and cacti shall be salvaged and replanted in areas requiring revegetation, whenever possible. b. Revegetation All cut or fill slopes that are no steeper than three horizontal to one vertical and all utility trenches or septic leaching fields that are not located in parking or driveway areas shall be revegetated in compliance with the following standards: (1) All plants used in revegetation shall be the same as the native vegetation on the site prior to grading or clearing or any adjacent site; and, (2) Revegetation shall be accomplished with the following minimum standards for plants: (a) Desert trees, a minimum of 15-gallon size with a minimum trunk diameter of two inches measured at the soil level, or large specimen cactus shall be placed at the same vegetation density found on the site prior to any clearing, grubbing, or grading; and, (b) Seeds for trees, desert shrubs, and grasses shall be planted with a density adequate to control erosion and may use one of the following methods of planting: Raked into the soil with appropriate mulch materials; hydroseeding; anchored mulches; or established on jute, rolled straw, or similar material. Another method may be approved by PDSD. (3) A temporary watering system shall be installed until the revegetation materials are established. 3. Slope Stabilization All slopes steeper than a ratio of three horizontal to one vertical, with the exception of retaining walls, shall be stabilized with properly engineered stone riprapping or sculptured rock as follows: a. Stone riprapping shall be hand-placed on the slope; b. The stabilizing material used shall blend with the natural appearance of the site or lot and the surrounding terrain; and, c. Vegetation retention and revegetation should be used in conjunction with riprapping. Thank you. Chad Keller, RLA Landscape Architect chad.keller@tucsonaz.gov 520.837.4923 |
||
| 07/18/2025 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 07/24/2025 | CDRC Review Coordinator Express | REVIEW COMPLETED | EXTERNAL REVIEWERS CDRC added ADRESSING, and TEP, SWG USPS, and PAG to the workflow. Review request email sent to ADRESSING, and TEP. FYI email sent to, SWG USPS PAG. |
||
| 08/14/2025 | Commercial Plumbing Standard | REVIEW COMPLETED | |||
| 07/24/2025 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | FYI CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. |
||
| 08/19/2025 | External Reviewers - Pima County Addressing Standard | REVIEW COMPLETED | Good afternoon, Pima County Addressing approves TD-DEV-0725-00188. Nicholas Jordan Site Review Project Manager II – Addressing Official Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-9623 |
||
| 07/24/2025 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | FYI CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. |
||
| 07/24/2025 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | FYI CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. |
||
| 08/13/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 07/23/2025 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 07/23/2025 | OK to Submit - Zoning Fast | REVIEW COMPLETED | |||
| 07/28/2025 | ROW Engineering Review Standard | REVIEW COMPLETED | DTM ROW Engineering has no comments. |