Permit Review Detail
Review Status: In Review
Review Details: DEVELOPMENT PACKAGE NEW v.5
Permit Number - TD-DEV-0725-00179
Review Name: DEVELOPMENT PACKAGE NEW v.5
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/26/2026 | Site Engineering Standard | APPROVED | |||
| N/A | NPPO Standard | PENDING ASSIGNMENT | |||
| N/A | Site Landscape Standard | PENDING ASSIGNMENT | |||
| N/A | Site Zoning Standard | PENDING ASSIGNMENT | |||
| 04/07/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | 1. Finish adding the location and size of the public sanitary sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; along with the Pima County Wastewater Management Department (PCWMD) reference number to sheets CG-05 and CG-06. [Second Comment: Drawings for the Tucson Auto Mall Sewerage System can be found at: https://onbase.pima.gov/publicaccess/WW_NextGen_Single/etc/cq/results.html?cqid=161&OBKey__157_1=G%2D86%2D023 ] [Initial comment: Revise the site drawing to include the following existing utility information: The location and size of the public sanitary sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; along with the Pima County Wastewater Management Department (PCWMD) Reference number. Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2018.] 2. The rim elevation of the next upstream sanitary manhole (4664-08, 2303.52’) is higher than the first floor elevation of the service building (2302.98’). Provide a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson [Second comment: Answer pending][Initial comment: Determine the need for backwater valves per Section 714.1, IPC 2018, as amended by the City of Tucson.] 3. Provide the rim elevation of the next upstream sanitary manhole from the connection of the building sewer for the proposed Honda showroom 4664-09). Determine the need for a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson. 4. If it is your intent to use the civil plans from the development plan for construction of on-site utilities (e.g. water service to the buildings, building sewers, etc.). Revise the civil plans to provide complete installation drawings of the site utilities. Reference: Sections 107.2.1 and 107.2.6, IBC 2018. If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov |