Permit Number: TD-DEV-0724-00210
Parcel: 10610005D

Address:
2020 W PRINCE RD

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-0724-00210
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/23/2024 NPPO APPROVED
12/23/2024 Site Landscape APPROVED
12/18/2024 Site Zoning APPROVED
12/23/2024 CDRC Post Review PENDING ASSIGNMENT
12/10/2024 Commercial Plumbing REQUIRES RESUBMIT 1. The orientation of the cleanout has been drawn incorrectly. Correct the drawing. [Initial comment: Revise the last cleanout in the building sewer to show the drainage fittings installed to guide sewage in the direction of flow. Reference: Section 706.3, IPC 2018.]
2. The building sewer requires the installation of a backwater valve. If any plumbing work is to be done in the new warehouse, the backwater valve must be installed. [Initial comment: The rim elevation of the next upstream sanitary manhole (3100-07, 2284.50’) is less than 12” below the first floor elevation (2284.86’). Provide a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson.]
12/18/2024 Site Engineering REQUIRES RESUBMIT 1. Please add a petroleum filter (i.e. sand oil separator) to the loading dock sump pump to comply with Tucson Code 26-40: Prohibited Discharges. The number of loading docks presents a pollution concern. Show the filter and sump pump in a detail on the plan set.

Mike Ortiz
michael.ortiz@tucsonaz.gov
11/15/2024 CDRC Application Completeness REVIEW COMPLETED
11/26/2024 ROW Review REVIEW COMPLETED