Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.2
Permit Number - TD-DEV-0724-00210
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/23/2024 | NPPO | APPROVED | |||
12/23/2024 | Site Landscape | APPROVED | |||
12/18/2024 | Site Zoning | APPROVED | |||
12/23/2024 | CDRC Post Review | PENDING ASSIGNMENT | |||
12/10/2024 | Commercial Plumbing | REQUIRES RESUBMIT | 1. The orientation of the cleanout has been drawn incorrectly. Correct the drawing. [Initial comment: Revise the last cleanout in the building sewer to show the drainage fittings installed to guide sewage in the direction of flow. Reference: Section 706.3, IPC 2018.] 2. The building sewer requires the installation of a backwater valve. If any plumbing work is to be done in the new warehouse, the backwater valve must be installed. [Initial comment: The rim elevation of the next upstream sanitary manhole (3100-07, 2284.50’) is less than 12” below the first floor elevation (2284.86’). Provide a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson.] |
||
12/18/2024 | Site Engineering | REQUIRES RESUBMIT | 1. Please add a petroleum filter (i.e. sand oil separator) to the loading dock sump pump to comply with Tucson Code 26-40: Prohibited Discharges. The number of loading docks presents a pollution concern. Show the filter and sump pump in a detail on the plan set. Mike Ortiz michael.ortiz@tucsonaz.gov |
||
11/15/2024 | CDRC Application Completeness | REVIEW COMPLETED | |||
11/26/2024 | ROW Review | REVIEW COMPLETED |