Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0724-00198
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/13/2024 | Commercial Plumbing | APPROVED | |||
08/06/2024 | Fire New Construction | NOT REQUIRED | |||
08/15/2024 | NPPO | NOT REQUIRED | |||
07/26/2024 | ROW Engineering Review | NOT REQUIRED | |||
08/15/2024 | Site Landscape | NOT REQUIRED | |||
08/15/2024 | CDRC Post Review | PENDING ASSIGNMENT | |||
08/12/2024 | Site Engineering | REQUIRES RESUBMIT | Please address Site Zoning comments | ||
08/08/2024 | Site Zoning | REQUIRES RESUBMIT | CDRC TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Costco - 6255 E GRANT RD – ADA Upgrades Development Package (1st Review) TD-DEV-0724-00198 TRANSMITTAL DATE: August 8, 2024 DUE DATE: August 10, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is July 24, 2025. 2-06.4.0 CONTENT REQUIREMENTS 1. COMMENT: 2-06.4.1 – Provide the email address for the owner, architect and civil listed on sheet 1. 2. COMMENT: 2-06.4.3 – Provide the development package case number, TD-DEV-0724-00198, adjacent to the title block on all sheets. 3. COMMENT: 2-06.4.4 – A small, project-location map shall be provided in the upper right corner of the cover sheet. This map shall cover approximately one square mile, be drawn at a minimum scale of three inch equals one mile, and provide the following information. Show the subject property approximately centered within the one square mile area. Identify major streets within the square mile area and all streets that abut the subject property. Section, township, and range, north arrow, and the scale will be labeled. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 4. COMMENT: 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. 5. COMMENT: 2-06.4.7.A.6.a - As Grant Rd is designated as an Arterial on the COT MS&R Map provide a general note on the cover sheet stating “THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, UDC ARTICLE 5.4 MAJOR STREETS AND ROUTES SETBACK ZONE (MS&R)”. If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised development package as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |
||
07/11/2024 | CDRC Application Completeness | REVIEW COMPLETED | |||
07/25/2024 | CDRC Review Coordinator | REVIEW COMPLETED | External Reviewers not required. No further action is required from the customer at this time. | ||
07/22/2024 | OK to Submit - Engineering | REVIEW COMPLETED | |||
07/18/2024 | OK to Submit - Zoning | REVIEW COMPLETED |