Review Date Reviewer's Name Type of Review Description Status Comments
10/07/2024 Site Engineering APPROVED
10/08/2024 CDRC Post Review Express PENDING ASSIGNMENT
10/08/2024 NPPO REQUIRES RESUBMIT See Site Landscape Comments.

Thank you,
Chad Keller, RLA
chad.keller@tucsonaz.gov
09/10/2024 ROW Engineering Review REQUIRES RESUBMIT TD-DEV-0724-00193 • 2524 S WILMOT RD

1. The pedestrian circulation path along projects property frontage shall be brought into compliance with Sec. 10-01.4.0. of the UDC Technical Standards Manual. This includes replacing any out of compliance curb access ramp and replacing any sidewalk sections that are broken/cracked or where the cross slope exceeds 2%. The minimum sidewalk width along an arterial roadway is 6ft.

2. Per Sec. 6.3.2 of the Transportation Access Management Guidelines for the City of Tucson, a Traffic Impact analysis will be required for this development.

If you have any questions, please contact Richard Leigh at 520-403-0970 or email richard.leigh@tucsonaz.gov.
10/08/2024 Site Landscape REQUIRES RESUBMIT CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
PDSD SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: DP SITE PLAN SUBMITTAL FOR THE FRY'S #33 FUEL CENTER
ACTIVITY NO: TD-DEV-0724-00193
ADDRESS: 2524 S WILMOT RD
ZONING: C-2 COMMERCIAL ZONE

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting.

Please resubmit revised drawings along with a detailed response letter, which states how all Landscape/NPPO Review Section comments are addressed.

SITE LANDSCAPE/NPPO SECTION COMMENTS:

1. The Development Package is incomplete. Two Development Packages for the same project site is not standard practice. The development package must include the civil site plan, grading plan and landscape plans. The previous site landscape comments have not been satisfied. Revise the plans to reflect all the comments from the previous submittal.

If you have any questions about these comments, I can be reached at chad.keller@tucsonaz.gov
10/03/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Fry’s #33 Fuel Center - 2524 S WILMOT RD
Development Package (2nd Review)
TD-DEV-0724-00193

TRANSMITTAL DATE: October 3, 2024

DUE DATE: October 6, 2024

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is July 11, 2025.

2-06.2.0 APPLICATION SUBMITTAL REQUIREMENTS

1. COMMENT: 2-06.2.4 – Remove the elevation sheets from the DP as they are not part of the site review and will not be reviewed at this time.

2-06.4.0 CONTENT REQUIREMENTS

2. COMMENT: 2-06.4.4 – The project-location map shall cover approximately one square mile and be drawn at a minimum scale of three inch equals one mile

3. COMMENT: 2-06.4.4.A – The project-location map shall show the subject property approximately centered within the one square mile area.

4. COMMENT: 2-06.4.4.C – Label the section corners, and the scale of the location map.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

5. COMMENT: 2-06.4.9.Q – Provide the square footage of the Kiosk and canopy within the footprint on the plan.

6. The proposed pedestrian path shown out to Golf Links Rd presents a safety hazard. If a vehicle is at the pump fueling where is a pedestrian supposed to go. COMMENT: 2-06.4.9.R - Per TSM Section 7-01.4.1.A provide a sidewalk/pedestrian refuge from the proposed kiosk to the sidewalk located within the right-of-way along Golf Links Rd, (TSM Section 7-01.2.B.1)

If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised development package as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf.
09/06/2024 CDRC Application Completeness Express REVIEW COMPLETED
10/07/2024 Commercial Plumbing REVIEW COMPLETED