Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0626-00172
Parcel: 11105022C

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-0626-00172
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/09/2026 CDRC Review Coordinator Express PENDING ASSIGNMENT
07/09/2026 Commercial Plumbing Standard PENDING ASSIGNMENT
07/09/2026 Fire New Construction Standard PENDING ASSIGNMENT
07/09/2026 NPPO Standard PENDING ASSIGNMENT
07/09/2026 ROW Engineering Review Standard PENDING ASSIGNMENT
07/09/2026 Site Engineering Standard PENDING ASSIGNMENT
07/09/2026 Site Landscape Standard PENDING ASSIGNMENT
07/09/2026 Site Zoning Standard PENDING ASSIGNMENT
07/06/2026 OK to Submit - Engineering Fast REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0626-00172 (OK To Submit Review)
Project: Development Package for a small restaurant, GEMS Tucson
Location: 3338 E FORT LOWELL RD
Review Date: 7/6/2026
Reviewer: Marco Contreras – Engineering Associate
Reviewer Contact Information: marco.contreras@tucsonaz.gov
Related cases:

Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards.
The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files.

Applicable Code Links for quick/direct reference:
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf
City of Tucson Chapter 25: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-18593

Site Engineering Application Completeness Review Comments:
1. Application incomplete, please provide the following for resubmission:
a. Provide an earthwork table that provides: preferably on the cover sheet
i. Cut & Fill quantities associated with the proposed grading & construction
ii. Total area of disturbance in both square footage & acres.
b. Provide the associated SWPPP Required IF proposed disturbance exceeds 1-acre. Ensure to include 1-4 SWPPP pages in main plan set file.
07/09/2026 OK to Submit - Zoning Fast REQUIRES RESUBMIT 1. COMMENT: Address Site Engineering Comment.
2. COMMENT: Include the development package case number (TD-DEV-0626-00172) on the bottom right corner of each sheet, adjacent to the title block.

Loran Shamis
loran.shamis@tucsonaz.gov
07/06/2026 CDRC Application Completeness Express REVIEW COMPLETED