Permit Number: TD-DEV-0626-00158
Parcel: 13506136H

Address:
2550 S KOLB RD

Review Status: In Review

Review Details: DEVELOPMENT PACKAGE NEW v.3

Permit Number - TD-DEV-0626-00158
Review Name: DEVELOPMENT PACKAGE NEW v.3
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
N/A Site Zoning Standard PENDING ASSIGNMENT
08/31/2026 Site Engineering Standard REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0626-00158 (2nd Review)
Project: 2 EV Level 3 Charging Stations to be installed at the exiting Walmart Neighborhood Market.
Location: 2550 S KOLB RD
Review Date: 8/31/2026
Reviewer: Marco Contreras – Engineering Associate & Joe Macaulay – Civil Engineer
Reviewer Contact Information: marco.contreras@tucsonaz.gov
Related cases:

Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards.
The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files.

Applicable Code Links for quick/direct reference:
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf
City of Tucson Chapter 25: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-18593

Site Engineering Review Comments:
1. Previous Comment #9 – As the space described is not intended to be parking spaces, but rather a pedestrian circulation path/area to connect the ADA EV spaces to the main site, It will be required that Vertical Separation requirements are fully addressed then.
a. It will be required that both ADA EV spaces be provided with Wheel Stops – It is acknowledged that parking signs are provided, these are not a sole acceptable item within this scope for meeting vert sep.
b. Sidewalks associated with PAALs must be physically separated from any vehicular travel lane by means of curbing, grade separation (minimum six inches), barriers, railings, or other means, except at designated crosswalks [TSM 7-01.4.2]. In order for this pedestrian area to be considered protected, it could be completed using more bollards. Ensure they (bollards) are spaced no less than 4-ft and no more than 5-ft separate UDC 7.4.6. Provide a measurement call-out on the site plan view. This will need to be demonstrated in between the northern PAAL and referenced northern area above the keynote #9’s.