| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/18/2026 | Site Engineering Standard | APPROVED | |||
| 10/01/2026 | Site Zoning Standard | APPROVED | |||
| 10/01/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | ACTIVITY NO. TD-DEV-0626-00155 ADDRESS/PARCEL: 2626 N COLUMBUS BL TUCSON, AZ 85712 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: 1. A backwater valve is required for Duplex Building 1. The RIM elevation of the nearest upstream manhole is 2444.06 and the FFE is 2444.70. Since the FFE is less than 12 inches above the elevation of the next upstream manhole, a backwater valve is required. Reference: Section 714.1, IPC 2024, as amended by the City of Tucson. |
||
| 09/11/2026 | External Reviewers - Pima County Addressing Standard | REQUIRES RESUBMIT | Good afternoon, Pima County Addressing is returning TD-DEV-0626-00155 with the attached comments. Thank you, David Wilging Planner I - Addressing Division Pima County Development Services 201 N. Stone Avenue 1st Floor Tucson, Arizona 85701 520-724-6381 **SEE ATTACHMENTS SECTION FOR THE RESUBMTTAL REQUEST FROM ADDRESSING** |
||
| 09/30/2026 | ROW Engineering Review Standard | REQUIRES RESUBMIT | Onsite manuverbility not shown correctly. Show parking spaces. If new service connections are not shown in ROW, show pavement cuts. |