Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0626-00154
Parcel: 11707216A

Address:
711 S 6TH AV

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-0626-00154
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/23/2026 CDRC Review Coordinator Express PENDING ASSIGNMENT
06/23/2026 Commercial Plumbing Standard PENDING ASSIGNMENT
06/23/2026 Fire New Construction Standard PENDING ASSIGNMENT
06/23/2026 Historic PENDING ASSIGNMENT
06/23/2026 NPPO Standard PENDING ASSIGNMENT
06/23/2026 ROW Engineering Review Standard PENDING ASSIGNMENT
06/23/2026 Site Engineering Standard PENDING ASSIGNMENT
06/23/2026 Site Landscape Standard PENDING ASSIGNMENT
06/23/2026 Site Zoning Standard PENDING ASSIGNMENT
06/18/2026 OK to Submit - Engineering Fast REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0626-00154 (OK To Submit Review)
Project: Classroom and Storage Additions
Location: 711 S 6TH AV
Review Date: 6/18/2026
Reviewer: Marco Contreras – Engineering Associate
Reviewer Contact Information: marco.contreras@tucsonaz.gov
Related cases:

Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards.
The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files.

Applicable Code Links for quick/direct reference:
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf
City of Tucson Chapter 25: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-18593

Site Engineering Application Completeness Review Comments:
1. Application incomplete, please provide the following for resubmission:
a. Grading plan sheet(s) have not been included in the submittal package. A grading plan prepared, signed, and sealed by a licensed Arizona Civil Engineer is required. At minimum, the grading plan shall address the following:
i. Existing topography depicted with 1- or 2-foot contour intervals, including benchmark and datum reference (NAVD 88)
ii. Proposed contours and/or spot elevations, including finished grade elevations at all building corners, parking areas, and drainage structures
iii. Limits of Disturbance (LOD) delineating the full extent of all proposed grading and drainage-related improvements
iv. Earthwork table - Cut and fill quantities, including total area of disturbance (sq. ft.) and earthwork volumes
v. Engineer of Record stamp and signature block
06/23/2026 OK to Submit - Zoning Fast REQUIRES RESUBMIT 1. COMMENT: Include a general note stating the existing and proposed zoning is HC-3.
2. COMMENT: Include a general note identifying the proposed use per UDC 11.3 – DEFINITIONS OF LAND USE GROUPS, CLASSES AND TYPES.
3. COMMENT: Provide a parking calculation that demonstrates compliance with UDC Table 7.4.4-1.
4. COMMENT: Provide the development package case number (TD-DEV-0626-00154) in the lower right corner adjacent to the title block on each sheet.
5. COMMENT: Address Site Engineering comments.

Loran Shamis
loran.shamis@tucsonaz.gov
06/18/2026 CDRC Application Completeness Express REVIEW COMPLETED