Permit Review Detail
Review Status: In Review
Review Details: DEVELOPMENT PACKAGE NEW v.2
Permit Number - TD-DEV-0626-00151
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/23/2026 | External Reviewers - COT Parks & Recreation Standard | APPROVED | CDRC, Approved Regarding TD-DEV-0626-00151, the City of Tucson Parks and Recreation Department has no additional requirements for the Project and no further reviews by TPRD are required. Parcel: 13101002H Regards, Joe Barr Project Manager Tucson Parks and Recreation 520-307-2811 |
||
| N/A | Commercial Plumbing Standard | PENDING ASSIGNMENT | |||
| N/A | External Reviewers - Tucson Airport Authority Standard | PENDING ASSIGNMENT | |||
| N/A | Fire New Construction Standard | PENDING ASSIGNMENT | |||
| N/A | NPPO Standard | PENDING ASSIGNMENT | |||
| N/A | ROW Engineering Review Standard | PENDING ASSIGNMENT | |||
| N/A | Site Landscape Standard | PENDING ASSIGNMENT | |||
| N/A | Site Zoning Standard | PENDING ASSIGNMENT | |||
| 09/29/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0626-00151 Project: Freedom Park Community Garden Location: 5000 E 29TH ST Review Date: 9/29/2026 Reviewer: Joe Macaulay – Civil Engineer – Site Development Reviewer Contact Information: joe.macaulay@tucsonaz.gov Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards. The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files. Applicable Code Links for quick/direct reference: City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf City of Tucson Chapter 25: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-18593 Site Engineering Review Comments: 1. Please add the name, mailing address, email and phone number of the primary property owner of the site on the plan set cover sheet. [AM 2-06.4.1.A.1] 2. Provide the page number and total number of pages within the Development Package plan set (i.e., sheet xx of xx) on the bottom right corner of each page. [AM 2-06.4.2.D]. a. Currently, the plan set shows sheets “5 of 16” for both sheets GP01 & LS00. Revise the Index of Sheets and bottom right corner sheet count accordingly. 3. Please add the required Drainage General Note “The developer, any successors and assigns, will hold the City of Tucson, its officers, employees, and agents harmless from any and all claims for damages related to the use of this development as shown hereon, now and in the future, by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall.” [AM 2-06.4.3.A] 4. Please add required Drainage General Note “Drainage will remain in its natural state and will not be altered, disturbed, or obstructed other than as shown on this site plan.” [AM 2-06.4.3.D] 5. Please add required Drainage General Note “This project is affected by the City of Tucson Floodplain Regulations.” 6. Please add required Drainage General Note ““A floodplain use permit and/or finished floor elevation certificates are required.” 7. Provide dimensions for all curb return radii for the Maintenance Access Drive Aisle. 8. Please provide a cross section and/or material section of the Maintenance Access Drive Aisle providing surfacing depth information. 9. Please provide the MS&R designation for E 29TH ST on the plan sheets. 10. Please provide hatching on sheet SP01 for the Maintenance Access Drive Aisle as shown on sheet LS00. Waste Collection Comments: 11. It is unclear with the layout of the compost bins how they will be accessed for compost pick-up. Regarding compost bin requirements and maneuverability, any changes or need to deviate from waste standards would have to get approval from Environmental Services. You may need to contact Andy Vera, Andy.Vera@tucsonaz.gov, for any approvals necessary, or in case you need a Technical Standards Modification Request (TSMR). a. Please verify compost locations and maneuverability is acceptable to Environmental Services. b. Based upon determination of Environmental Services, further comments may be forthcoming. 12. Pedestrian circulation is required to connect all buildings, dumpster areas, common areas, and the sidewalk on all the street frontages. [TSM 7-01.3.3] a. Please provide pedestrian access to compost bins. Drainage and Grading Comments: 13. Please show the COT Flood Hazard Zone (100-yr flood plain) limits for Swan Road Wash throughout the plan set. 14. The grading plans lack sufficient spot elevation and or grading contour information at key drainage control points necessary to verify design intent and facilitate site inspections during and after construction. Provide spot elevations at all of the following locations: a. All landscaped water harvesting area inlet and overflow points. b. Grade at key transitions throughout the site to confirm positive drainage is maintained as designed. c. At raised planter bed locations. Drainage Report Comments: 15. Please provide discussion within the report regarding the existing COT Flood Hazard Zone (100-yr flood plain) limits and delineate the limits within the report. |
||
| 09/22/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added Parks & Rec, TAA, PAG, SWG, USPS, TEP to the workflow. FYI notice sent out to PAG, SWG, USPS, TEP. | ||
| 09/22/2026 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 09/22/2026 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 09/22/2026 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 09/22/2026 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 09/21/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 09/21/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED |