Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0625-00150
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/02/2025 | Site Landscape Standard | NOT REQUIRED | |||
| 07/02/2025 | NPPO Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: SITE DEVELOPMENT REVIEW FOR A DETACHED GARAGE AT AN EXISTING SFR ACTIVITY NO: TD-DEV-0625-00150 ADDRESS: 11 N TUCSON TE ZONING: R-1 RESIDENCE ZONE This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all of the Site Landscape and NPPO Section review comments have been addressed. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. Provide a NPPO or a NPPO Waiver. If protected native plants will not be disturbed during the construction of the detached garage, or if there are no protected natives within the construction areas, then the waiver is applicable. If a copy of the waiver is need, please reach out to my email attached below. Thank you. Chad Keller, RLA Landscape Architect chad.keller@tucsonaz.gov 520.837.4923 |
||
| 07/07/2025 | Site Engineering Standard | REQUIRES RESUBMIT | 1. See Technical Standards Manual section 9-01.3.1 for correct ACS formula to revise the overall graded area percentage. 2. Show the distinction between the existing and new grading work. Provide the new limits of grading associated with the proposed garage including area of disturbance in acres and cut/fill quantities in cubic yards. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
||
| 07/03/2025 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner Planning & Development Services Department – Zoning Review Section PROJECT: TD-DEV-0625-00150– Residential – Site Development Review for a Detached Garage at an existing SFR 11 N Tucson TE. Tucson, AZ 85745 (R-1 Zoning) Development Package Review – 1st Review TRANSMITTAL DATE: July 2, 2025 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is June 02, 2026. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) Section 2-06.3.0 FORMAT REQUIREMENTS 2-06.3.5 - A three-inch by five-inch space shall be reserved in the lower right quadrant of each sheet for an approval stamp. 1. COMMENT: Provide three-inch by five-inch space for approval stamp per 2-06.3.5 standard. 2-06.3.6 - Provide a blank three-inch by five-inch block in the lower right corner of the plan adjacent to the title block on the first sheet of the development package for use by Pima County Addressing. 2. COMMENT: Provide three-inch by five-inch space for Pima County Addressing per 2-06.3.6 standard. 2-06.3.10 - A legend that shows and describes all symbols used on the drawing is to be provided, preferably on the first sheet. 3. COMMENT: Complete legend and plan. Plans are missing setbacks and any easement(s) indicated on the legend and both contour types are missing on the legend from the plan. Spell out what WM and PP are in the legend. 2-06.3.12 - An index of sheets in the development package shall be provided on the first sheet. 4. COMMENT: Update the list of drawings per UDC Technical Standards 9-01.2.0 Plan Format and Content Requirements. CONTENT REQUIREMENTS 2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. The applicable registration or license number shall be provided if prepared by or with the assistance of a registered professional, such as a surveyor, architect, landscape architect, or engineer. All sealing shall be consistent with Arizona Board of Technical Registration guidelines. 5. COMMENT: Update the title block to include all licensed registrants associated with this project per the 2-06.4.1 standard. 2-06.4.2 - The title block shall include the following information and be provided on each sheet: 2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx). 6. COMMENT: Update the title block sheet number total per UDC Technical Standards 9-01.2.0 Plan Format and Content Requirements. 2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet. 7. COMMENT: Provide the development package case number, TD-DEV-0625-00150 and Hillside Development Zone (HDZ) overlay adjacent to the title block on each sheet. 2-06.4.5 - When the development package documents consist of more than one sheet, a sheet index (a legible drawing of the site showing the area represented on each sheet) is to be placed on the cover sheet or the second sheet. 8. COMMENT: Update the list of drawings per UDC Technical Standards 9-01.2.0 Plan Format and Content Requirements. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. 9. COMMENT: Per 2-06.4.7.A.4 standard, provide existing and proposed use (Residential / Family Dwelling / Single-Family, Detached) 2-06.4.7.A.6 - If a plan or plat is prepared in conjunction with other applications or overlays or the parcel being developed is subject to conditions of an application processed previously, additional information must be added to the plan. Such applications and overlays include, but are not limited to: annexations; rezonings; special exceptions; Board of Adjustment variances; Design Development Options; Technical Standard Modification Request; overlays (Airport Environs Zone, Environmental Resource Zone, Gateway Corridor Zone, Hillside Development Zone, Historic Preservation Zone, Major Streets and Routes, Rio Nuevo District, Scenic Corridor Zone, WASH); Modification of Development Regulations through the Downtown Area Infill Incentive District or Rio Nuevo District; Downtown Heritage Incentive Zone; or, Design Review Board. Provide the following information on the plan. 10. COMMENT: Per 2-06.4.7.A.6 standard, provide, provide Hillside Development Zone (HDZ) case number upon receipt and locate in lower right corner of each sheet.. 2-06.4.7.A.6.a - List additional applications and overlays, by case number (if applicable), in lower right corner of each sheet. As a general note provide the type of application processed or overlays applicable, a statement that the project meets the criteria/conditions of the additional application or overlay, the case number, date of approval, what was approved, and the conditions of approval, if any. 11. COMMENT: Per 2-06.4.7.A.6.a standard, provide Hillside Development Zone (HDZ) case number upon receipt. 2-06.4.7.A.8 - For development package documents provide: 2-06.4.7.A.8.a - Floor area for each building; 12. COMMENT: Per 2-06.4.7.A.8.a standard, provide floor area for each building. 2-06.4.7.A.8.b - Percentage and area in square feet of building and accessory building coverage; 13. COMMENT: Update percentage if total tally of building square footage from the previous comment response (2-06.4.7.A.8.a) changes. 2-06.4.7.B - Drainage Notes List the following notes as appropriate: 2-06.4.7.B.1 - List the following notes on all plans/plats: "The developer, any successors and assigns, will hold the City of Tucson, its officers, employees, and agents harmless from any and all claims for damages related to the use of this development as shown hereon, now and in the future, by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall." 14. COMMENT: Per 2-06.4.7.B.1 standard, provide this general note. 2-06.4.7.B.3 - List the following note on all development package documents: "Drainage will remain in its natural state and will not be altered, disturbed, or obstructed other than as shown on this site plan." 15. COMMENT: Per 2-06.4.7.B.3 standard, provide this general note. 2-06.4.7.C - Streets and Roads Notes 16. COMMENT: It appears the graphic depicting the existing driveway location on the plan drawing is inconsistent with aerial imagery. In particular, the portion that enters/leaves the property to the north and the property lines it runs beside. Provide and accurate depiction of the driveway location. 2-06.4.7.D - Utilities Note All development package documents are to include the following note: "Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public." 17. COMMENT Per 2-06.4.7.D standard, provide this general note. 2-06.4.8.A - Provide site boundary/subdivision perimeter information, including bearing in degrees, minutes, and seconds, with basis for bearing noted, together with distances in feet, to hundredths of a foot, or other functional reference system. 18. COMMENT: Per 2-06.4.8.A standard, provide this general note. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. If the property is being rezoned, use those boundaries and classifications. The basis for this requirement is that some zoning requirements on a project are based on the zoning classification of adjacent property. Also, in some instances, each zone has to be taken into consideration on property that is split by two or more zoning classifications, as each may have different requirements. 19. COMMENT: Per 2-06.4.9.F standard, provide this general note. 20. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other the PDSD reviewer comments If you have any questions about this transmittal, please contact Jeffrey Cassidy, (520) 837-4916 or Jeffrey.Cassidy@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revise development package. |
||
| 06/02/2025 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 06/11/2025 | CDRC Review Coordinator Express | REVIEW COMPLETED | EXTERNAL REVIEWERS CDRC added TEP, ADOT, PAG, USPS, SWG to the workflow. Review request email sent to TEP, and ADOT. FYI email sent to PAG, USPS, SWG. |
||
| 07/01/2025 | Commercial Plumbing Standard | REVIEW COMPLETED | |||
| 06/13/2025 | External Reviewers - Arizona Department of Transportation (ADOT) Standard | REVIEW COMPLETED | Good Afternoon, ADOT has reviewed this DEV and has no comments. Thank you for the opportunity to review. |
||
| 06/11/2025 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | FYI CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. |
||
| 06/11/2025 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | FYI CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. |
||
| 07/23/2025 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | 4350 E. Irvington Road Post Office Box 711, Tucson, AZ 85702 July 23, 2025 WO#T154064 City of Tucson Planning and Development Services Attn: CDRC Admin Team Dear CDRC Admin Team Subject: Timmerman Detached Garage TD-DEV-0625-00150 Tucson Electric Power Company (TEP) has reviewed and approved the development plan submitted 6/11/2025. There are no existing facilities within the development. There are no apparent conflicts at this time. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. To apply for electric service, please call the New Construction department at (520) 918- 8300. Please submit a final set of plans including approved site, electric load, paving off-site improvements and irrigation plans. If available, include a PDF version of the plans. If easements are required, they will be secured by separate instrument. Should you have any easement questions, please contact our Land Resources Department, LandReviews@tep.com. Should you have any technical questions, please contact the area designer, Fred Quintero (520) 235-6329 fquintero@tep.com Sincerely, Design Admins Design Admins Tucson Electric Power |
||
| 06/11/2025 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | FYI CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. |
||
| 06/12/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 08/06/2025 | Historic Standard | REVIEW COMPLETED | This property is located in the Menlo Park National Historic District. It is not in any HPZ. Based on this HPZ review is not required. However, the project is located within an Archaeological Sensitivity Zone. If any human remains are encountered during any digging, trenching or construction, state law (Arizona Antiquities Act) requires that you cease work and notify the proper authorities. In this case, please reach out to the City Historic Preservation Office immediately, and/or the Arizona State Museum. Please contact Michael.Taku@tucsonaz.gov with any questions. |
||
| 06/10/2025 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 06/05/2025 | OK to Submit - Zoning Fast | REVIEW COMPLETED | |||
| 06/18/2025 | ROW Engineering Review Standard | REVIEW COMPLETED |