Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.2
Permit Number - TD-DEV-0624-00181
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/12/2026 | Floodplain Administration Review Standard | REQUIRES RESUBMIT | Address the following comments in addition to the PDSD Engineering comments per TS Sec 2-01, UDC Sec.5.2, TC Sec. 26-8: 1) For soils report, provide slope stability recommendations. 2) City of Tucson Floodplain Administration will not accept the proposed improvements within the erosion hazard setback. Revise grading design. 3) Show Interceptor swale at uphill side of cut slope. 4) Delineate grading limits to include areas for construction activities. 5) Label total disturbance area for building pad grading construction, and total disturbance area for driveway grading excluding parking area at garage. 6) Clarify extents of hand-placed rip rap on grading plan. 7) Show Hillside calculations on grading plan using city method. 8) Provide Civil Engineer’s seal for grading plan. 9) Show location of wall openings for patio areas. 10) Provide spot elevations and flow arrows on grading planview for patio and driveway areas to clarify how drainage will be directed to spillways / wall openings and not create ponding issues. 11) Provide cross sections for each side of building pad showing gradients away from building and toward wall openings. 12) Provide additional grading spot elevations along eastside of parking / driveway area near front of house, to show that there is positive gradient to avoid ponding issues. Elizabeth Eberbach P.E., CPM. CFM Civil Engineer City of Tucson 520-429-4905 elizabeth.eberbach@tucsonaz.gov |
||
| 08/29/2025 | NPPO | REQUIRES RESUBMIT | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA PDSD SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: GRADING PERMIT REQUIRED BY PLAT ACTIVITY NO: TD-DEV-0624-00181 ADDRESS: 2079 S LITTLE DIPPER DR ZONING: R-1 RESIDENCE ZONE; HILLSIDE DEVELOPMENT ZONE REVIEW 2 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all Landscape/NPPO Review Section comments are addressed. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. Include Native Plant Preservation Ordinance verification by a native plant professional. Refer to UDC 7.7.4.D. Professional Expertise: Preparation of all elements of the Native Plant Preservation Plan and on-site monitoring as required under Section 7.7.5.C.5, On- Site Monitoring, must be performed by a plant professional, such as: 1. An arborist certified by the International Society of Arboriculture; 2. A landscape architect; or, 3. A horticulturist, biologist, or botanist with a minimum B.A. or B.S. in an appropriate arid environment natural resource field. 2. Please identify the site monitor and list contact information on the NPPO sheet. Thank you. Chad Keller, RLA Chad.Keller@tucsonaz.gov 520.837.4923 |
||
| 01/12/2026 | Site Engineering | REQUIRES RESUBMIT | Permit: TD-DEV-0624-00181 Location: 2079 S LITTLE DIPPER DR Review Date: 1/12/2026 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Manual (TM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Comments: 1. As the site resides within hillside development zone overlay with proposed grading, it will be required that the submitted plans be stamped by a state registered civil engineer. 2. In accordance with the final plat for Wildcat Pass, general note #11, a floodplain use permit will be required for submission for associated development package. a floodplain use permit will be required to be submitted and approved prior to Site Engineering approving permit TD-DEV-0624-00181. The FPU permit is a separate permit that can be submitted for within the “sub-records” tab of this development package permit on TDC online. For the FPU permit submission, provide all construction documents similar to what was provide within this permit submission 3. As the proposed development involved grading work, as well as HDZ designation and proximity to Cholla Wash, a soils/Geotech report will be required for submission and review. Technical Standards Manual 2-01.4.1.D & E and 2-01.7.2 a. As the slope proposed along the edge of proposed building pad is greater than 3:1, geotechnical analysis and justification will be required for method of slope treatment as well as necessary setback in referenced to the erosion hazard wash. b. As this site is designated as Hillside Development Zone, include Average Natural Cross Slope (ACS) calculations on the grading plan/sheet in compliance with UDC 5.2 (HDZ) & Technical Standards Manual 9-01.0.0 (Hillside Development). These standards will be used to determine limits of total grading as well as other design standards. 4. In accordance with both the final plat and tentative plat for Wildcat Pass subdivision, the site/parcel is subject to WASH ordinance, ERZ, and Hillside compliance. 5. Referring to the Wildcat Pass Homeowners, although the HOA allowed the design to exceed outside the allowable building envelope as dictated by Star Pass guidelines, their approval will not supersede the City of Tucson’s guidelines relating to the erosion hazard setback. In compliance with the City of Tucson’s WASH and floodplain ordinance, encroachment into the erosion hazard setback will not be allowed for this development. Justification: a. TC Sec. 26-5.2(12): No development, storage of materials or equipment, or other uses shall be permitted which, acting alone or in combination with existing or future uses, create a danger or hazard to life or property. Development in the floodway fringe shall be constructed so as to protect placed fill from erosion which could be caused by waters, or otherwise. b. TC Sec. 26-5.2(3): No development, storage of materials or equipment, or other uses shall be permitted which, acting alone or in combination with existing or future uses, create a danger or hazard to life or property. Development in the floodway fringe shall not generate adverse impacts, including but not limited to erosion, upstream or downstream. c. TC Sec. 26-11.2(5)c: All new construction and substantial improvements shall be constructed by methods and practices that minimize flood and erosion damage. 6. Provide a Cross-section detail showing the area along the property line to the north. This cross-section detail should show that the 2-feet minimum grading setback from the property line on the grading plan TSM 2-01.9.0. NOTE: Depending on the Top of cut or Toe of fill shown in the detail, a greater setback may be required in compliance with TSM 2-01.9.0 a. If a less minimum setback is desired, geotechnical justification will be required. 7. For resubmission, please provide the “Final” approval given by the HOA. 8. A general note must be added to the plan stating this lot is subject to WASH ordinance, ERZ, and Hillside compliance. It should be noted that additional Site Engineering comments may be forthcoming in future review cycles as provided comments and development changes may bring forth further callouts. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 08/29/2025 | Site Zoning | REQUIRES RESUBMIT | CDRC TRANSMITTAL FROM: Bobby Parsons PDSD Zoning Review Section PROJECT: 2079 S. Little Dipper Dr. Tucson, AZ 85745 Development Package For Grading (2nd Review) TD-DEV-0624-00181 (grading permit required per plat) TRANSMITTAL DATE: 8/29/2025 DUE DATE: 8/29/2025 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Comment: Site zoning is unable to approve this grading permit until Engineering approval is obtained. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, Contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package and comment response letter. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/pdsd/website/Resubmittals.pdf. |
||
| 08/29/2025 | Commercial Plumbing | REVIEW COMPLETED |