08/01/2023 | Site Engineering | APPROVED | |||
08/04/2023 | Site Zoning | APPROVED | |||
08/31/2023 | CDRC Post Review | PENDING ASSIGNMENT | |||
08/31/2023 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Provide the rim elevation of manhole 4589-01. [Initial comment: The location and size of public and private sanitary sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; along with the Pima County Wastewater Management Department (PCWMD) reference number. Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2018.] 2. The sewer inverts are not needed; compare the manhole rim elevation to the FFE. [Initial comment: Determine the need for a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson. Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2018.] |
||