| 08/31/2023 | Commercial Plumbing | APPROVED | |||
| 08/25/2023 | External Reviewers - Tucson Airport Authority | APPROVED | August 25, 2023 Planning and Development Services City of Tucson 201 North Stone Avenue Tucson, AZ. 85701 RE: TD-DEV-0623-00263, Extension of Premises / 4573 S 12th Ave, Tucson, AZ 85714, Received August 3, 2023 To whom this may concern, Thank you for the opportunity to comment on TD-DEV-0623-00263, the development plan for an expansion of premises for an existing building at 4573 S 12th Ave. This development is located in the N.W. quarter of the S.W. quarter of Section 36, Township 14S, Range 13E, of the Gila and Salt River Meridian. The development site occupies parcel number 120-08-1020, covers approximately 0.197 ± acres, and is zoned as Commercial Zone 2 (C-2). The nearest major roadway intersection is West Ohio Street and South 12th Avenue, approximately 150 feet to the northeast of the subject development. This site does lie within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace. The Tucson Airport approves the proposed project and is not requiring a resubmit of this project. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520- 573-4811. Respectfully, Scott Robidoux, C.M. Manager of Planning |
||
| 08/03/2023 | Site Engineering | APPROVED | |||
| 08/09/2023 | NPPO | NOT REQUIRED | |||
| 08/09/2023 | Site Landscape | NOT REQUIRED | |||
| 09/05/2023 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 09/05/2023 | Site Zoning | REQUIRES RESUBMIT | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Loran Shamis PDSD Zoning Review Section PROJECT: TD-DEV-0623-00263 – Rollie’s patio expansion and enclosure Development Package (1st Review) TRANSMITTAL DATE: September 5, 2023 DUE DATE: August 30, 2023 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is June 5, 2024. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) 2-06.3.0 FORMAT REQUIREMENTS 1. COMMENT: 2-06.3.8 - The north arrow, contour interval, and scale as applicable to each sheet should be placed together in the upper right corner of each sheet. 2. COMMENT: 2-06.3.10 – Include a legend that shows and describes all symbols used on the drawing is to be provided, preferably on the first sheet. CONTENT REQUIREMENTS 3. COMMENT: 2-06.4.1 – Include the name, mailing and email addresses, and phone number of the primary property owner of the site. 4. COMMENT: 2-06.4.2.B – Include a brief legal description in the title block. 5. COMMENT: 2-06.4.2.D – Correct the sheet number for sheet 1, it currently says “2 OF 4”. 6. COMMENT: 2-06.4.3 - Provide the development package case number, TD-DEV-0623-00263, adjacent to the title block on each sheet. Include any additional application number if applicable. 7. COMMENT: 2-06.4.4.C – Include the Section, township, and range; section corners; north arrow; and the scale will be labeled with the project-location map. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. Zoning and Land Use Notes 8. COMMENT: 2-06.4.7.A.2 – Include the site gross area in acres. 9. COMMENT: 2-06.4.7.A.4 – Include a note stating the existing and proposed use is COMMERCIAL USE – FOOD SERVICES subject to use specific standards 4.9.4.M.1 and 4.9.13.P (UDC, 4.8.6, Table 4.8-4) 2-06.4.7.A.8 - For development package documents provide: 10. COMMENT: 2-06.4.7.A.8.c – Provide the percentage of building area expansion since the last approved site plan. It appears there are unpermitted structures on the site appearing in aerial around 2006, 2010, and 2021 - clarify and provide documentation if these structures were permitted; otherwise, the structures will be reviewed using today’s UDC standards. If the expansion exceeds 25% in floor area, full code compliance will be triggered for some standards - several of the following comments are relative to the expansion of building area being greater than 25%. You can submit a records request through the Tucson Development Center online. 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 11. COMMENT: 2-06.4.8.A – Include the site boundary information, including bearing in degrees, minutes, and seconds, with basis for bearing noted, together with distances in feet, to hundredths of a foot, or other functional reference system. 12. COMMENT: 2-06.4.8.C – Include the following information regarding existing and future right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 13. COMMENT: 2-06.4.9.F – Identify all existing zoning classifications on and adjacent to the project (including across any adjacent right of way) shall be indicated on the drawing with zoning boundaries clearly defined. 14. COMMENT: 2-06.4.9.H.5 – It appears the proposal exceeds 25% of the gross floor area. Per UDC 7.4.2 if an expansion is 25% or greater or if a series of expansions cumulatively results in 25% or greater expansion in floor area the requirements of 7.4 Motor Vehicle and Bicycle Parking apply to the entire site. Dimension the parking area access lane (PAAL) and the parking spaces. Per UDC 7.4.6.D the width of the PAAL should be 24’. 15. COMMENT: 2-06.4.9.H.5.a – Clarify where the ADA access aisle is located on the site plan. Zoning acknowledges the ADA parking space detail demonstrates an ADA access aisle, but it is unclear where the access aisle will be located. From aerials it appears the aisle is between the ADA parking space and the building to the east of the parking space, however the detail shows the aisle on the west side of the parking space. It is also unclear if the access aisle is proposed to remain with the patio expansion. 16. COMMENT: 2-06.4.9.H.5.a – The total gross floor area of the use is 2,082 square feet and the minimum parking requirement is 21 parking spaces. The proposal includes 19 parking spaces clarify how the proposal addresses the 2 remaining parking spaces. A Parking Design Modification Request (PDMR) may be used to reduce the parking requirement by up to 20%. An Individual Parking Plan (IPP) may also be used to reduce the parking requirement, contact Mark Castro at Mark.Castro@tucsonaz.gov. 17. COMMENT: 2-06.4.9.H.5.a – If the proposed expansion is greater than 25%, demonstrate compliance with UDC 7.4.6 Motor Vehicle Use Area Design Criteria. Demonstrate compliance with 7.4.6.H, Barriers. 18. COMMENT: 2-06.4.9.H.5.b – Provide a shared parking agreement or a cross access agreement with parcel 12008103A as the proposal includes parking on this adjacent site to meet the minimum parking requirement. Demonstrate that parcel 12008103A has enough parking to accommodate both sites’ parking. The site plan labeled this area as “alley” however this is the private property of parcel 12008103A. 19. COMMENT: 2-06.4.9.H.5.d – Demonstrate compliance with UDC 7.4.8, Required Number of Bicycle Parking Spaces, and 7.4.9 – Bicycle Parking Design Requirement. The short-term bicycle parking requirement is 1 space per 2,000 sq. ft. GFA with a minimum requirement is 2 spaces; and the long-term bicycle parking requirement is 1 space per 12,000 sq. ft. GFA. Minimum requirement is 2 spaces. 20. COMMENT: 2-06.4.9.H.O – Demonstrate all applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown. The minimum setback requirement for nonresidential uses adjacent to residential zones is 1.5 times the height of the proposed structure wall – it appears the existing building may not be meeting setbacks. If the existing building is not meeting zoning setback requirements, a Design Development Option (DDO) would be required. 21. COMMENT: 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s). 22. COMMENT: 2-06.4.9.R – If the proposed expansion exceeds 25%, the entire site is required to comply with Technical Standards Manual 7-01. Dimension the pedestrian circulation path which is required to be a minimum of 4’ wide. Additionally, a pedestrian circulation path is required to be adjacent to any parking spaces accessed by a PAAL where the space is located on the same side of the PAAL as any building. 23. COMMENT: 2-06.4.9.T – Show refuse collection areas including locations of dumpsters, screening location and materials, and vehicle maneuverability, fully dimensioned, and access route (Technical Standards Manual 8-01). 24. COMMENT: Additional comments may be forthcoming. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, Contact Loran Shamis by email Loran.Shamis@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package and comment response letter. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/pdsd/website/Resubmittals.pdf. |
||
| 07/31/2023 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 08/03/2023 | CDRC Review Coordinator Express | REVIEW COMPLETED | Added external reviewers, sent emails and sent FYI emails per SOP. | ||
| 08/04/2023 | External Reviewers - Arizona Department of Transportation (ADOT) | REVIEW COMPLETED | [EXTERNAL] Re: DUE AUGUST 30, 2023 / EXTENSION OF PREMISES / TD-DEV-0623-00263 Jay Gomes <jgomes@azdot.gov> CDRC Good Morning, ADOT has no comments on this DEV. Thank you for the opportunity to review. |
||
| 08/03/2023 | External Reviewers - Pima Association of Governments | REVIEW COMPLETED | Sent FYI emails per SOP. | ||
| 08/03/2023 | External Reviewers - Southwest Gas | REVIEW COMPLETED | Sent FYI emails per SOP. | ||
| 08/03/2023 | External Reviewers - Tucson Electric Power (TEP) | REVIEW COMPLETED | Sent FYI emails per SOP. | ||
| 08/03/2023 | External Reviewers - United States Postal Service (USPS) | REVIEW COMPLETED | Sent FYI emails per SOP. | ||
| 08/03/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 08/02/2023 | OK to Submit - Zoning Fast | REVIEW COMPLETED |