Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0526-00137
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/03/2026 | CDRC Review Coordinator Express | PENDING ASSIGNMENT | |||
| 06/03/2026 | Commercial Plumbing Standard | PENDING ASSIGNMENT | |||
| 06/03/2026 | Fire New Construction Standard | PENDING ASSIGNMENT | |||
| 06/03/2026 | NPPO Standard | PENDING ASSIGNMENT | |||
| 06/03/2026 | ROW Engineering Review Standard | PENDING ASSIGNMENT | |||
| 06/03/2026 | ROW Review | PENDING ASSIGNMENT | |||
| 06/03/2026 | Site Engineering Standard | PENDING ASSIGNMENT | |||
| 06/03/2026 | Site Landscape Standard | PENDING ASSIGNMENT | |||
| 06/03/2026 | Site Zoning Standard | PENDING ASSIGNMENT | |||
| 06/01/2026 | OK to Submit - Engineering Fast | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0526-00137 (1st Review) Project The proposed scope of work includes: Retrofitting and securing both metal carports onto engineered, permanent concrete footings to ensure long-term structural integrity and public safety. Performing necessary structural and cosmetic improvements to the carports to align with local building and aesthetic standards. Location: 5712 E SPEEDWAY BL Review Date: 6/1/2026 Reviewer: Marco Contreras – Engineering Associate Reviewer Contact Information: marco.contreras@tucsonaz.gov Related cases: Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards. The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files. Applicable Code Links for quick/direct reference: City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Review Comments: 1. Application incomplete – Refer to following comments: 2. As this submission is a new site plan submission for 5712 E SPEEDWAY BL – It should be treated as such, especially without an active/open development package for the site. This will be treated as a new site plan submission and the document (Plan-set). Should be formatted as such. This can be completed by removing all: a. Revision clouds/bubbles with deltas. Revisions are processed/handled to a development package only after it has been approved and issued |
||
| 06/03/2026 | OK to Submit - Zoning Fast | REQUIRES RESUBMIT | 1. COMMENT: Update the General Note 3 which states the proposed use is Commercial; however, this is not an identified use in the Unified Development Code. It appears the proposed use per the UDC is Retail - General Merchandise Sales, excluding large retail establishment subject to use specific standard 4.9.9.B.1. 2. COMMENT: Address Site Engineering comments. 3. COMMENT: The development package plan set should only include site plans, and details and notes related to the site. Please remove references to building/structural code. 4. COMMENT: Update the sheet index after addressing comment 2. Loran Shamis loran.shamis@tucsonaz.gov |
||
| 06/01/2026 | CDRC Application Completeness Express | REVIEW COMPLETED |