Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0526-00125
Parcel: 13220003A

Address:
3401 E GAS RD

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-0526-00125
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/20/2026 CDRC Review Coordinator Express PENDING ASSIGNMENT
05/20/2026 Commercial Plumbing Standard PENDING ASSIGNMENT
05/20/2026 Fire New Construction Standard PENDING ASSIGNMENT
05/20/2026 NPPO Standard PENDING ASSIGNMENT
05/20/2026 ROW Engineering Review Standard PENDING ASSIGNMENT
05/20/2026 ROW Review PENDING ASSIGNMENT
05/20/2026 Site Engineering Standard PENDING ASSIGNMENT
05/20/2026 Site Landscape Standard PENDING ASSIGNMENT
05/20/2026 Site Zoning Standard PENDING ASSIGNMENT
05/14/2026 OK to Submit - Engineering Fast REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0526-00125 (OK To Submit Review)
Project: SWG - New parking area expansion to include 20 parking spaces and ADA spaces. Includes a new perimeter fence and entrance gates.
Location: 3401 E Gas RD
Review Date: 5/14/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering
Related Cases:

*This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. *
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf
Site Engineering Review Comments:
1. Application incomplete, please provide:
a. A drainage report to show compliance with City of Tucson drainage requirements, including first flush retention. Based on initial review, it appears there is an increase of impervious coverage exceeding ~10,000 SQ Ft, therefore per DSSDR 2.1.2.b
b. Provide an earthwork table that provides total cut & fill quantities associated with the grading proposed, as well as total area of disturbance provided in both SQ feet and acres.
c. Revise plan set to align with the most current adopted code for the City of Tucson – 2024 IBC etc.
d. Further formatting is suggested. It appears two cover sheets are included with the provided plan set file.

If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov
05/20/2026 OK to Submit - Zoning Fast REQUIRES RESUBMIT 1. Please include the entire site in the site plan. Reference Sheet 1 on DP21-0251 for an example.
2. The sheet index states there are 17 sheets but the plan set contains 19 sheets. Ensure the sheet index is consistent with the number of sheets in the plan set.
3. Correct the Zoning classification under the Site Data, as it states the Zoning is I-7 but the Zoning is I-1.
4. Include an updated parking calculation. Refer to Sheet 1 on DP21-0251 for latest numbers to update with this proposal.

Loran Shamis
loran.shamis@tucsonaz.gov
05/14/2026 CDRC Application Completeness Express REVIEW COMPLETED