| 10/22/2026 | NPPO Standard | NOT REQUIRED | |||
| 10/08/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0526-00125 (1st Review) Project: Existing parking area extended for employee parking and new visitor parking with new added property perimeter fencing and gates. New light pole at new parking area. Location: 3401 E GAS RD Review Date: 10/8/2026 Reviewer: Marco Contreras – Engineering Associate & Joe Macaulay – Civil Engineer Reviewer Contact Information: marco.contreras@tucsonaz.gov & joe.macaulay@tucsonaz.gov Related cases: Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards. The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files. Applicable Code Links for quick/direct reference: City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf City of Tucson Chapter 25: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-18593 Site Engineering Review Comments: 1. Provide the development package case number (TD-DEV-0526-00125) adjacent to the title block on each sheet of the plan set. [AM 2-06.4.1.B.6] 2. Regarding the new access lanes proposed towards the Eastern portion of the site – the dimensional plan (Sheet 5) show these access lanes with a 18.1’ width. As these will function as two-way access lanes, it will be required that the lane widths be revised to 20-ft width. [UDC 7.4.6.D] 3. The site plan does not dimension all existing and proposed curb return radii at internal drive aisles and roadway access points. Provide dimensions for all curb return radii at the following locations: a. Confirm that all curb return radii comply with the dimensional requirements of Chapter 25, Streets and Sidewalks Standards and UDC 7.4.6.E.1.a. Where existing curb returns are to remain, document the existing radii and confirm compliance or identify any required modifications. b. It is acknowledged that the western curbing radii are noted. This should also be done for the Eastern area of the new development proposed. 4. Drainage Report – For resubmission, ensure that the drainage report is signed and sealed by the Civil Engineer. |
||
| 10/22/2026 | Site Landscape Standard | REQUIRES RESUBMIT | PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, PLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: PARKING AREA EXTENDED FOR EMPLOYEE PARKING AND NEW VISITOR PARKING WITH NEW ADDED PROPERTY PERIMETER FENCING AND GATES ACTIVITY NO: TD-DEV-0526-00125 ADDRESS: 3401 E GAS RD ZONING: LIGHT INDUSTRIAL ZONE (I-1) 10.22.2026 THE PROPOSED PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH APPLICABLE DEVELOPMENT STANDARDS FOR SITE LANDSCAPE, NATIVE PLANTS, AND RAINWATER HARVESTING, PER-THE-CITY OF TUCSON UNIFIED DEVELOPMENT CODE (UDC), TECHNICAL STANDARDS MANUAL (TSM), AND ADMINISTRATIVE MANUAL (AM). RESUBMIT REVISED DRAWINGS ALONG WITH A DETAILED RESPONSE LETTER, STATING HOW ALL SITE LANDSCAPE AND NPPO SECTION REVIEW COMMENTS HAVE BEEN ADDRESSED. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. This expansion in parking area requires only the area of the parking expansion to be brought up to code. The current planting plan looks good and appears to be following UDC 7.6.4. 2. Include a parking space calculation and the required tree and provided trees for compliance. 3. The street landscape border should be brought up to code in the area of the two new parking expansions. Include a summary and/or calculations that include existing plants and the proposed plants required to bring those portions of the borders up to code. 4. Include one additional tree near the east parking lot expansion. 5. This is a commercial-scale parking lot expansion with this number of new parking spaces. Include a commercial rainwater harvesting plan and calculations for the new asphalt parking areas and to the greatest extent possible provide drainage to the new tree-planting islands and any other areas that includes new plant material. 6. Call out the landscape meter as “irrigation only” to adhere to the commercial rainwater harvesting ordinance. 7. Sheets LA.03 and LA.04 are duplicates. Revise as necessary. 8. Include a preservation fencing detail for the existing trees to remain in place. Also, possibly include an additional sheet that shows the layout of the preservation fencing at the dripline or beyond the dripline of the tree if applicable. Or add that line work to the planting plan and call it out with a keynote or a leader callout. 9. Prior to site landscape approval, ensure that Site Zoning and Site Engineering comments are fully addressed. 10. Include the Activity Number TD-DEV-0526-00125 on all sheets in the plan set. Thank you. CHAD KELLER, PLA LANDSCAPE ARCHITECT CITY OF TUCSON, PDSD, SITE REVIEW SECTION CHAD.KELLER@TUCSONAZ.GOV 520.837.4923 |
||
| 10/20/2026 | Site Zoning Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL REVIEWED BY: Jeffrey Cassidy – Planner I PDSD Current Zoning Commercial Review Section PROJECT: Existing employee parking area expansion, new visitor parking with new perimeter fencing & gates Development Package (1st Review) TD-DEV-0526-00125 3401 E GAS RD TUCSON, AZ 85714 I-1 ZONING TRANSMITTAL DATE: October 20, 2026 Per UDC Section 3.3.3.G.5.c, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year expiration date is May 13, 2027. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-8753 1. COMMENT: An index of sheets in the development package shall be provided on the first sheet. (AM 2-06.3.5). 2. COMMENT: Provide the development package case number, TD-DEV -0526-00125, adjacent to the title block on each sheet. (AM 2-06.4.1.B.6). 3. COMMENT: On sheet 1, under general notes, provide a general note that states “Existing Zoning is I-1” and under site data from I-7 to I-1. (AM 2-06.4.2.A). 4. COMMENT: On sheet 1, under general notes, update the Existing and Proposed Use: Commercial Use – Administrative and Professional Office per UDC 4.9.13.Q. (AM 2-06.4.2.D). 5. COMMENT: On the cover sheet, under general note(s) indicate that this development is subject to Airport Environs Zone (AEZ) per UDC 5.6 and remove note referencing Major Streets and Routes (AM 2-06.4.2.F). 6. COMMENT: Per previous zoning reviewer comment, provide existing context footprints of all of the existing buildings, accessory structures, parking, etcetera on site and include all of the square footage of each (Reference fDP21-0251). (AM 2-06.4.2.H). 7. COMMENT: Provide percentage of vehicular use area expansion, including previous expansions. (AM 2-06.4.2.I). 8. COMMENT: Per previous zoning reviewer comment, provide a vehicle parking calculation table to communicate existing required, provided and proposed spaces. Include all required and provided accessible parking spaces and respective types (Reference DP21-0251). (AM 2-06.4.2.J). 9. COMMENT: Provide missing zoning (labels) for all surrounding / adjacent parcels (Including across the right of way for E Gas Rd and S palo Verde Rd) (AM 2-06.4.7.F). 10. COMMENT: Similar to Comment 6, illustrate all buildings and provide the square footage, the height, and the proposed use(s). (AM 2-06.4.7.H). 11. COMMENT: If applicable, draw, label and dimensions all existing and proposed easements providing sequence numbers that can be referenced with county records. (AM 2-06.4.7.I). 12. COMMENT: Clarify why the proposed accessible van space and associated aisle dimensions vary from Accessible Parking Spaces | ADA.gov on the site plan and detail. Update both accordingly. (AM 06.4.7.Q.4) 13. COMMENT: A bicycle rack is included in the detail sheet but not labeled on the site plan. Update the site plan or detail sheet accordingly. (AM 06.4.7.Q.4) 14. COMMENT: There are three locations where the proposed access lane has a proposed 18’-0” and/or 18.1’ dimension. Per UDC Table 7.4.6-2, a 20’-0” dimension is required. Update design accordingly. (AM 06.4.7.Q.4). 15. COMMENT: The detail sheet indicates and typical parking space to include a wheel stop. Update the site plan to demarcate if this is truly ‘typical’ or reserved to specific locations and remove ‘typical’ from the title of the detail title. (AM 06.4.7.Q.4). 16. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please resubmit revised drawings and any corrected plans along with a detailed response letter, stating how all Site Zoning Review comments were addressed. **Instructions for resubmittal - www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. ***For additional information on the standards presented in this memo, please refer to the City of Tucson Administrative Manual Section 2-06 or Technical Standards noted in the comments. If you have any questions about this transmittal, please contact Jeffrey.cassidy@tucsonaz.gov |
||
| 09/29/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added ADOT, TAA, PAG, SWG, USPS, TEP to the workflow. FYI notice sent out to PAG, SWG, USPS, TEP. | ||
| 10/19/2026 | Commercial Plumbing Standard | REVIEW COMPLETED | |||
| 10/26/2026 | External Reviewers - Arizona Department of Transportation (ADOT) Standard | REVIEW COMPLETED | ADOT has no comments. Thanks, Rick Freije |
||
| 09/29/2026 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 09/29/2026 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 10/26/2026 | External Reviewers - Tucson Airport Authority Standard | REVIEW COMPLETED | October 21, 2026 Planning and Development Services City of Tucson 201 North Stone Avenue Tucson, AZ. 85701 RE: TD-DEV-0526-00125, 1st Submittal, Southwest Gas Corporation - Site Improvements / 3401 E Gas Rd, Tucson, AZ. 85714 / Received September 29, 2026 To whom this may concern, Thank you for the opportunity to comment on TD-DEV-0526-00125, 1st Submittal, a development plan for site improvements for an existing office building at 3401 E Gas Rd. This development is located in the N.E. quarter of the S.W. quarter of Section 33, Township 14S, Range 14E, of the Gila and Salt River Meridian. The development site occupies parcel number 132-20-003A, covers approximately 17.10 ± acres, and is zoned as Light Industrial Zone (I-1). The nearest major roadway intersection is East Gas Road and South Palo Verde Road, approximately 100 feet to the southeast of the subject development. This site does lie within the Tucson International Airport avigation easement requirements and public disclosure area and FAA traffic pattern airspace. The Tucson Airport Authority does not object to the first submittal of this project and is not requiring a resubmittal of this project. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520- 573-4811. Respectfully, Scott Robidoux, C.M. Manager of Planning cc file |
||
| 10/26/2026 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 09/29/2026 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI Notice email sent. No further action is required. | ||
| 10/20/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 09/25/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 09/29/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED | |||
| 10/14/2026 | ROW Engineering Review Standard | REVIEW COMPLETED | |||
| 10/07/2026 | ROW Review | REVIEW COMPLETED |