Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0526-00119
Parcel: 115070750

Address:
1742 N ORACLE RD

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.3

Permit Number - TD-DEV-0526-00119
Review Name: DEVELOPMENT PACKAGE NEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/10/2026 External Reviewers - COT Environmental Services Standard APPROVED
08/06/2026 Historic APPROVED Approval for DP only. Proposed facade alterations and new building design to be approved under building permits. Questions? Email desiree.aranda@tucsonaz.gov.
08/03/2026 ROW Engineering Review Standard APPROVED Right of Way permit required.
08/05/2026 Site Landscape Standard APPROVED
08/07/2026 Site Zoning Standard APPROVED
08/06/2026 TSMR/PDMR - Engineering APPROVED
07/31/2026 TSMR/PDMR - Zoning APPROVED
08/05/2026 NPPO Standard NOT REQUIRED
08/04/2026 Commercial Plumbing Standard REQUIRES RESUBMIT ACTIVITY NO. TD-DEV-0526-00119
ADDRESS/PARCEL: 1742 N ORACLE RD TUCSON, AZ 85705

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Previous comment not fully addressed. [Initial comment - Please show the proposed point of connection for the building sewer and show the location and routing of the sewer line. Also, show the location of all cleanouts.]
a. Please provide a complete site sewer plan showing how all buildings are connected to the public sewer. The sewer connections for new Building #2, Building #4, and Building #7 are not shown. Reference: Section 107.2.1, IBC 2024.
2. Building #7 will require a backwater valve. The RIM elevation of the nearest upstream manhole (#8154-02) is 2361.90 and the FFE is 2362.72 & 2362.06. Since the FFE is less than 12 inches above the elevation of the next upstream manhole, a backwater valve is required. Reference: Section 714.1, IPC 2024, as amended by the City of Tucson.
3. Please correct the flow direction of the public sewer shown on the site plan. The public sewer flows north from MH #8154-02 to MH #8154-01.
08/03/2026 Site Engineering Standard REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0526-00119 (2nd Review)
Project: Change of use from travelers' accommodation to retail and food service. Adding 2 additional structures and expanding one existing structure.
Location: 1742 N ORACLE RD
Review Date: 8/3/2026
Reviewer: Marco Contreras – Engineering Associate & Joe Macaulay – Civil Engineer
Reviewer Contact Information: marco.contreras@tucsonaz.gov
Related cases:

Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards.
The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files.

Applicable Code Links for quick/direct reference:
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf
City of Tucson Chapter 25: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-18593

Site Engineering Review Comments:
1. Clarification & potential revision required – the plans show keynote #36 as downspouts for the proposed new building #2. Are these downspouts going to be connected to an underground pipe network, or discharged directly onto the sidewalk along the Western side of the building?
a. Revise the plans to show and call out any new/proposed sidewalk scuppers that may be needed in order to effectively route the downspouts under the applicable sidewalks.