| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/05/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | ACTIVITY NO. TD-DEV-0526-00119 ADDRESS/PARCEL: 1742 N ORACLE RD TUCSON, AZ 85705 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov. COMMENTS: 1. Please identify the water meter and backflow preventer serving each proposed building. Also, show the route, size, and material of the water service line to each building. Reference: Section 107.2.1, IBC 2024. 2. Please show the proposed point of connection for the building sewer and show the location and routing of the sewer line. Also, show the location of all cleanouts. Reference: Section 107.2.1, IBC 2024. |
||
| 06/11/2026 | External Reviewers - COT Environmental Services Standard | REQUIRES RESUBMIT | Must include all enclosure details and dimensions within submitted drawings for review and approval. Refer to TSM 8-01.0 for minimum requirements. Feel free to contact me if you have any questions. Andy Vera (520) 837-3798 Andy.Vera@tucsonaz.gov |
||
| 06/02/2026 | Historic | REQUIRES RESUBMIT | Resubmit required for Historic review. Please see comments previously provided under activity number TP-PRE-0426-00094. These comments outline requirements for maintaining contributing Historic status, which is required for the parking reduction incentive under UDC Section 7.4.5.D. Please reach out to desiree.aranda@tucsonaz.gov with any questions or to discuss the comments provided. | ||
| 06/09/2026 | NPPO Standard | REQUIRES RESUBMIT | See site landscape comments for NPPO Waiver requirement. Thank you. Chad Keller, PLA chad.keller@tucsonaz.gov |
||
| 06/10/2026 | ROW Engineering Review Standard | REQUIRES RESUBMIT | -Show sidewalk connection from corner to alley along W. Elm St and W Lester. -Sidewalk shall be 5' wide install per PAG 200. -Show ADA ramps at Alley. -Recommended PAG 206 driveway on W Elm St -Recommended 12' width on one way exit. |
||
| 05/21/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0526-00119 (1st Review) Project: Minor Development Package for the addition of a concrete loading area to the existing Living Spaces facility. Location: 1742 N ORACLE RD Review Date: 5/21/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering *This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. * City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Review Comments: 1. Revise general note #16 – the City of Tucson adopted The IBC 2024 with ICC A117.1 2017 edition – Ensure to revise keynote #27 to follow suit with current adopted standards. 2. For resubmission – ensure to include the submission of the TSMR request as referenced by general note #28. TSMR’s are to be processed after the first full review cycle of the development package activity. 3. Revise the site plan sheet 3 provided to provide Sight visibility triangles for site entrances in compliance with TSM 10-01.5.0. NOTE: Oracle RD is designated as an Arterial Road and Elm ST is designated as a local road. These designations will be used for Table 5.3. Refer to TSM 10-01.9.0 Figures 16-18 for examples of SVTs. 4. Due to the change of use intensity – it will be required to provide a keynote/call-out for all structure (Existing & Proposed) downspouts and sidewalk scupper locations on the site & grading sheets. This is to ensure compliance with building permit plan reviews. This keynote should be provided on the grading sheets. This is to demonstrate compliance with TSM 7-01.4.3.E & 7-01.4.1.E 5. Provide clarification and/or revise the parking dimensions shown for the spaces shown where the ADA parking is provided. The current plans show 15.8’ long spaces. 6. Demonstrate how the new proposed building on the West of the falls in compliance with TSM 7-01.3.3. by being connected to the site’s pedestrian circulation. 7. Provide the new modified trash enclosure construction detail as referenced by keynote #28. 8. Based on fire determination – the proposed access lane/stie entrances may be required to be widened for fire access. 9. Keynote 32 calls out for new canopy – denote the proposed height and Sq-footage of this intended canopy. If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 06/09/2026 | Site Landscape Standard | REQUIRES RESUBMIT | PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, PLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: CHANGE OF USE FROM TRAVELERS' ACCOMMODATION TO RETAIL AND FOOD SERVICE. ADDING 2 ADDITIONAL STRUCTURES AND EXPANDING ONE EXISTING STRUCTURE ACTIVITY NO: TD-DEV-0526-00119 ADDRESS: 1742 N ORACLE RD ZONING: COMMERCIAL ZONE (C-3) LAND USE: COMMERCIAL RETAIL 6.9.2026 THE PROPOSED PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH APPLICABLE DEVELOPMENT STANDARDS FOR SITE LANDSCAPE, NATIVE PLANTS, AND RAINWATER HARVESTING, PER-THE-CITY OF TUCSON UNIFIED DEVELOPMENT CODE (UDC), TECHNICAL STANDARDS MANUAL (TSM), AND ADMINISTRATIVE MANUAL (AM). RESUBMIT REVISED DRAWINGS ALONG WITH A DETAILED RESPONSE LETTER, STATING HOW ALL SITE LANDSCAPE AND NPPO SECTION REVIEW COMMENTS HAVE BEEN ADDRESSED. SITE LANDSCAPE/NPPO COMMENTS: 1. This is a partial landscape plan set. There may be additional comments during the next review cycle. 2. Provide planting details, irrigation plan and details, commercial rainwater harvesting plan and calculations and all other applicable details and specifications needed for construction of this project. 3. Include all pertinent calculations needed to demonstrate compliance: IE: parking lot trees, street landscape border trees and 50 percent coverage with understory plant material. 4. State on the plan set that this project is not opting into the Infill Incentive District landscape alternative requirements. 5. Make sure there is an “irrigation only” meter for compliance with the commercial rainwater harvesting ordinance. 6. The 40-foot half ROW is shown along Oracle. Clearly show and label the existing and future ROW lines and sight visibility triangles in all applicable locations on this site. 7. W. Elm and W. Lester both require street landscape borders. If a portion of the ROW is needed, then coordinate with David Marhefka, PLA with DTM for approval. David.Marhefka@tucsonaz.gov. Include any related correspondence materials and approvals with the next submittal. 8. If these two borders are not achievable, then a Board of Adjustment Variance may be required to gain relief from this requirement. 9. As referenced above, the northern portion of N. Oracle Rd. requires a street landscape border in the areas not used for ingress and egress. If this is not achievable, then the Board of Adjustment Variance is required. 10. It is pretty clear that this site does not contain any protected native plant material. For our records and for yours, please provide the waiver that indicates that native plants have been considered on this site and none exist. 11. Prior to site landscape approval, ensure that Site Zoning and Site Engineering comments are fully addressed. Thank you. Chad Keller, PLA Landscape Architect chad.keller@tucsonaz.gov 520.837.4923 |
||
| 06/16/2026 | Site Zoning Standard | REQUIRES RESUBMIT | 1. COMMENT: Although this property is a contributing structure to the Miracle Mile National Registered Historic District, it does not fall within an established “Historic Preservation Zone”; as such, amend General Note 24 to remove the portion stating “UDC SEC. 5.8, "H" HISTORIC PRESERVATION ZONE (HPZ)/"HL" HISTORIC LANDMARK (HL).” 2. COMMENT: Given that the project is seeking to utilize UDC Section 7.4.5.D. to modify minimum parking requirements on site, the maintenance of contributing status is required. Please follow guidance from the Historic Preservation Section regarding what changes to the proposal are necessary to maintain such status. 3. COMMENT: Provide a note indicating what percentage of the total gross floor area is dedicated to the proposed accessory uses of “Food Service” and “Multifamily Development”. 4. COMMENT: Per UDC Technical Standards Manual Section 7-01.4.3.A, the minimum width for a sidewalk is four feet. The sidewalk adjacent to the new 1-story addition is only 2.6’. Even with a Technical Standards Modification Request (TSMR), the minimum width to which it can be reduced is 3’ per ADA accessibility standards. 5. COMMENT: The minimum length of a parking space is 18’; only 15.8’ is shown for parking spaces in front of building 6. These appear to be spaces modified from their current configuration. Modified spaces are required to meet current code requirements. 6. COMMENT: Demonstrate pedestrian circulation between new 1-story building three and the remainder of the site per UDC TSM 7-01.4.1.D. Contact Fernando Garcia, Lead Planner, Site Zoning at fernando.garcia2@tucsonaz.gov. |
||
| 05/14/2026 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 05/18/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added Real estate, Design Professional, Environmental Services, Addressing, ADOT, TEP, PAG, USPS, and SWG to the workflow. Review request email sent to Addressing, ADOT, and TEP. FYI email sent to PAG, USPS, SWG. | ||
| 05/20/2026 | Design Review Standard | REVIEW COMPLETED | Applicant has indicated the IID will not be used for this project. | ||
| 05/29/2026 | External Reviewers - Arizona Department of Transportation (ADOT) Standard | REVIEW COMPLETED | CDRC ADOT has no comments. Thanks, Rick Freije |
||
| 05/18/2026 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 05/21/2026 | External Reviewers - Pima County Addressing Standard | REVIEW COMPLETED | CDRC Good afternoon, Pima County Addressing approves of TD-DEV-0526-00119. Thank you, David Wilging Planner I - Addressing Division Pima County Development Services 201 N. Stone Avenue 1st Floor Tucson, Arizona 85701 520-724-6381 |
||
| 05/18/2026 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 06/10/2026 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | June 9, 2026 WO#T184687 City of Tucson Planning and Development Services Attn: CDRC Admin Team Dear CDRC Admin Team Subject: Crystal Hacienda TD-DEV-0526-00119 Tucson Electric Power Company (TEP) has reviewed and approved the development plan submitted 5/18/2026. There are existing facilities within the development which are depicted upon the plan. No apparent conflicts, contact TEP design if service relocation is required. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. To apply for electric service, please call the New Construction department at (520) 918- 8300. Please submit a final set of plans including approved site, electric load, paving off-site improvements and irrigation plans. If available, include a PDF version of the plans. Questions regarding Land, ROW, Easement, etc., please contact the TEP Land Department Liz Boehler Right of Way Agent Consultant 520-686-1341 Landreviews@tep.com Should you have any technical questions, please contact the area designer, Martin Salazar (520) 305-6713 msalazar@tep.com Sincerely, Design Admins Design Admins Tucson Electric Power |
||
| 05/18/2026 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 06/06/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 05/14/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 06/15/2026 | Real Estate Standard | REVIEW COMPLETED | Please contact the Real Estate Division if any property rights need to be addressed. |