Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0525-00148
Parcel: 12112358B

Address:
5118 E PIMA ST

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.3

Permit Number - TD-DEV-0525-00148
Review Name: DEVELOPMENT PACKAGE NEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/09/2026 NPPO Standard APPROVED
10/12/2026 Site Engineering Standard APPROVED
10/15/2026 Site Zoning Standard APPROVED
10/12/2026 TSMR/PDMR - Engineering APPROVED
10/12/2026 Commercial Plumbing Standard REQUIRES RESUBMIT ACTIVITY NO. TD-DEV-0525-00148
ADDRESS/PARCEL: 5118 E PIMA ST TUCSON, AZ 85712

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:
1. Please show the size of the water meter on the site plan, and indicate the size and material of the water service pipe serving the new triplex. Reference: Section 107.2.1, IBC 2024.
2. Please show all building sewer cleanouts on the site plan.
a. Show the cleanout at the junction of the building drain and the building sewer. Reference: Section 708.1.3, IPC 2024.
b. Please provide a cleanout in the building sewer prior to entering the right-of-way. Reference: Pima County Standard Detail RWRD 401, 2021.
3. This additional information will be used for the Utility Permit. Please reach out to me when you resubmit so I can review it right away.
10/13/2026 Site Landscape Standard REQUIRES RESUBMIT PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, PLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: DEVELOPMENT PACKAGE FOR MULTIFAMILY DEVELOPMENT
ACTIVITY NO: TD-DEV-0525-00148
ADDRESS: 5118 E PIMA ST
ZONING: C-1 COMMERCIAL ZONE
LAND USE: MULTIFAMILY
OFFICIAL REVIEW 2
10.13.26

THE PROPOSED PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH APPLICABLE DEVELOPMENT STANDARDS FOR SITE LANDSCAPE, NATIVE PLANTS, AND RAINWATER HARVESTING, PER-THE-CITY OF TUCSON UNIFIED DEVELOPMENT CODE (UDC), TECHNICAL STANDARDS MANUAL (TSM), AND ADMINISTRATIVE MANUAL (AM).

RESUBMIT REVISED DRAWINGS ALONG WITH A DETAILED RESPONSE LETTER, STATING HOW ALL SITE LANDSCAPE AND NPPO SECTION REVIEW COMMENTS HAVE BEEN ADDRESSED.

SITE LANDSCAPE/NPPO SECTION COMMENTS:

1. State that the irrigation meter is for “irrigation only” within keynote number 18.

2. Include PVC sleeving for the irrigation lines crossing hardscape. The sleeve is called out on the trenching detail, but it is recommended to show the sleeve graphically on the plan and on the legend.

3. Include a keynote callout for screened rock for all planting areas and any other area of bare soil or disturbed ground, e.g. (one-inch screened rock in the color of your choice at a depth of two inches minimum.)

4. E PIMA ST is a major local road and that designation is a MS&R. The parking is ancillary to the multifamily designation of the overall site and the multifamily use along both the MS&R and Non-MS&R requires the standard street landscape border requirements with the trees and 50 percent vegetative ground cover.

5. ***It requires two street landscape border trees within 10 feet of parking spaces to count as one parking lot tree. Please include an additional tree near the parking spaces. My apologies for missing this on the last review cycle.

See UDC 7.6.4.B. Vehicular Use Areas: The standards in this Section 7.6.4.B apply to all developments that provide more than four motor vehicle parking spaces, except as provided in Section 7.6.4.B.1.c, Exemptions.
1. Canopy Trees in Vehicular Use Areas
a. General Standards
Within a vehicle use area, one canopy tree is required for each four motor vehicle parking spaces or fraction thereof.
(1) The canopy trees must be evenly distributed throughout the vehicular use area. Every parking space must be located within 40 feet of the trunk of a canopy tree (as measured from the center of the tree trunk).
***(2) Fifty percent of the trees required for landscape borders located within ten feet of the paved portion(s) of a vehicular use area may be counted towards both the minimum parking lot canopy tree standard and the landscape border canopy tree standard.


Thank you.

CHAD KELLER, PLA
LANDSCAPE ARCHITECT

CITY OF TUCSON, PDSD, SITE REVIEW SECTION
CHAD.KELLER@TUCSONAZ.GOV
520.837.4923
09/23/2026 CDRC Application Completeness Express REVIEW COMPLETED
10/14/2026 Fire New Construction Standard REVIEW COMPLETED
10/01/2026 TSMR/PDMR - Zoning REVIEW COMPLETED