Permit Number: TD-DEV-0524-00153
Parcel: 140327180

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.3

Permit Number - TD-DEV-0524-00153
Review Name: DEVELOPMENT PACKAGE NEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/01/2024 Commercial Plumbing APPROVED
10/14/2024 CDRC Post Review PENDING ASSIGNMENT
10/09/2024 NPPO REQUIRES RESUBMIT 1. There are still 3 velvet mesquite transplants shown on the plans: 1 on sheet 9, and 2 on sheet 10. Since the one on sheet 9 has not been updated to (T) and still says "T", it is likely an error. The change in labeling to (T) and (t) has not been updated on the "NPPO Requirements Summary" section of sheet 10. Please revise the plans to show consistency for labeling and transplant numbers across all sheets.

Mike Ortiz
michael.ortiz@tucsonaz.gov
10/09/2024 Site Engineering REQUIRES RESUBMIT 1. The cover sheet is showing only block 1 and as the northern block which doesn't match the rest of the plan set, revise as needed.
2. Take a look at the line weights and styles throughout the plan set, there are some displayed that don't show up in the legend and several lines with the same style when they are clearly different type of lines, revise as needed.
3. To ensure the trash enclosure will meet standards found in TSM section 8-01 show the clear space between bollards on the detail. This should be a minimum of 10 feet.
4. Per Admin manual 2-06.4.2.B the legal description in the title block needs to refer to this plat as a resubdivision, revise as needed.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
10/09/2024 Site Landscape REQUIRES RESUBMIT see NPPO comments
10/08/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Desert View Plaza Commercial, Block 1
Development Package (2nd Review)
TD-DEV-0524-00153

TRANSMITTAL DATE: October 8, 2024


COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is October 8, 2025.

1. Show compliance with UDC 7.4.6.H.1, demonstrating sufficient pedestrian refuge.
2. Zoning acknowledges that the minimum sidewalk width is 6.5'. Please show the individual sidewalk widths on the site plan.
3. Ensure all line weights in the legend and site plan are consistent. There appears to be a line dedicated to zoning boundaries that is not on the legend.
4. Ensure consistency with all proposed blocks. There appears to be a proposal of 2 blocks. The cover sheet only has Block 1 shown.

If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised development package as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf.
09/03/2024 CDRC Application Completeness REVIEW COMPLETED
10/14/2024 External Reviewers - Pima County Addressing REVIEW COMPLETED Good morning,



Pima County Addressing approves TD-DEV-0524-00153.



Nicholas Jordan

Site Review Project Manager II – Addressing Official

Pima County Development Services Department

201 N Stone AV – 1st Floor

Tucson, AZ 85701

(520) 724-9623
10/03/2024 Fire New Construction REVIEW COMPLETED
09/09/2024 ROW Engineering Review REVIEW COMPLETED DTM ROW Engineering has no comments.