Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Approved
Review Details: DEVELOPMENT PACKAGE NEW v.5
Permit Number - TD-DEV-0524-00150
Review Name: DEVELOPMENT PACKAGE NEW v.5
Review Status: Approved
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/09/2025 | Commercial Plumbing | APPROVED | 1. The revised FFE values for the lots and the manhole rim elevations have corrected the identification of the lots requiring backwater valves with only one minor issue. Lot 33 does not have a backwater valve symbol on the partial plans on sheet 13 of 31. The notes on sheets 2 of 31 and 5 of 31 correctly show lot 33 requiring a backwater valve. 2. For future reference: a backwater valve is required only if the FFE is LESS than 12” above the rim elevation of the next upstream manhole. |
||
01/10/2025 | CDRC Post Review Express | REVIEW COMPLETED |