Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/26/2024 | Site Engineering | APPROVED | |||
12/10/2024 | Site Zoning | APPROVED | |||
12/10/2024 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
11/25/2024 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Based on the current submittal, dated 10/23/24, lots 2-4, 7, 19, 25-28, 30-32, 35-42, and 44-53 do not appear to require backwater valves (i.e., The FFE for each lot is 12” or more above the rim elevation of the next upstream manhole). 2. The boxed note on sheet 5 of 31 and Wastewater note #5 on sheet 2 of 31 will need to be corrected to list which lots require backwater valves. |
||
10/28/2024 | CDRC Application Completeness Express | REVIEW COMPLETED |