Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TD-DEV-0523-00256
Parcel: 138244260

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-0523-00256
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/31/2023 CDRC Post Review PENDING ASSIGNMENT
05/31/2023 CDRC Review Coordinator PENDING ASSIGNMENT
05/31/2023 Commercial Plumbing PENDING ASSIGNMENT
05/31/2023 External Reviewers - COT Parks & Recreation PENDING ASSIGNMENT
05/31/2023 External Reviewers - Pima Association of Governments PENDING ASSIGNMENT
05/31/2023 External Reviewers - Southwest Gas PENDING ASSIGNMENT
05/31/2023 External Reviewers - Tucson Airport Authority PENDING ASSIGNMENT
05/31/2023 External Reviewers - Tucson Electric Power (TEP) PENDING ASSIGNMENT
05/31/2023 External Reviewers - United States Postal Service (USPS) PENDING ASSIGNMENT
05/31/2023 Fire New Construction PENDING ASSIGNMENT
05/31/2023 NPPO PENDING ASSIGNMENT
05/31/2023 Site Engineering PENDING ASSIGNMENT
05/31/2023 Site Landscape PENDING ASSIGNMENT
05/31/2023 Site Zoning PENDING ASSIGNMENT
05/31/2023 Traffic Engineering Review PENDING ASSIGNMENT
05/31/2023 OK to Submit - Engineering REQUIRES RESUBMIT 1. A drainage report will be required for this site. It must show first flush retention and balanced basin detention being proposed.
2. The plans appear to propose underground storm water storage. Ensure that the next submittal includes all required documents from section 4.13.1 of the Stormwater Detention-Retention Manual, including an engineer's report of structure stability and Conditions, Covenants and Restrictions (CCRs)
with inspection and maintenance responsibilities. Additionally, the Manual requires that underground retention is approved by the floodplain administrator. Specify that retention is not occurring in the underground system in the drainage report or email Stephen Blood at stephen.blood@tucsonaz.gov for approval.
3. Include grading cut and fill quantities.

Lianne Evans
lianne.evans@tucsonaz.gov
05/31/2023 OK to Submit - Landscape REQUIRES RESUBMIT PROJECT: STORAGE 365
ACTIVITY NO. TD-DEV-0523-00256
ADDRESS/PARCEL: 6555 S MIDVALE PARK RD/138-24-4260
ZONING: O-3

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TSM) Section for landscape, native plants and water harvesting.

Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments are addressed.

COMMENTS:
1. This plan set is missing the following documents:
a. NPPO or NPPO waiver.
b. Landscape Plan - Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10.
c. Irrigation plan- Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10.
d. Commercial rainwater harvesting plan – A Commercial Rainwater Harvesting Plan is required per UDC Technical Standards Manual – Section 4-01.3.0. and Section 5-01.0.0 Landscaping and Screening. Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design. Using Low Impact Development design and water harvesting provides critical basin detention and first flush retention for all new development and impervious area. The newly adopted Detention/Retention Manual can be found: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf

With CoT edits to the manual are found at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf
2. Ensure the required number of trees is in all vehicular parking areas (1 tree: 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.
3. Maximize the rainwater harvesting across the site into the landscape areas, including but not limited to the street landscape borders as well as the tree wells for the required trees for the parking lot.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988
05/31/2023 OK to Submit - Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Storage 365
6555 S. Midvale Park Rd – O-3 to C-2
TD-DEV-0523-002256

TRANSMITTAL DATE: May 31, 2023

The development package has been reviewed by the Zoning Review Section for minimal compliance with the Administrative Manual Section 2-06. It has been determined that the submitted plans do not provide sufficient information to complete a plan review. The following items need to be addressed prior to re-submittal.

1. Provide the conditions of rezoning, TP-ENT-1222-00009, on the plan
2. See Engineering & Landscape comments

If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov.
05/30/2023 CDRC Application Completeness REVIEW COMPLETED