Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0523-00251
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/28/2023 | Commercial Plumbing | APPROVED | |||
| 06/30/2023 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 06/21/2023 | NPPO | REQUIRES RESUBMIT | See Landscape Notes. | ||
| 06/21/2023 | Site Engineering | REQUIRES RESUBMIT | This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TI’s and solar). Construction of separate builds/new structures does not require a cost estimate to be provided. Instructions: 1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record 2. Locations -> Confirm the location is accurate to the project. Click “Next” 3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next” 4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next” 5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next” 6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next” 7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next” 8. Review and Submit -> Review all information to ensure accuracy. Click “Submit” Contact Lianne Evans at lianne.evans@tucsonaz.gov or Stephen Blood at Stephen.Blood@tucsonaz.gov if you have any questions about the FUP. |
||
| 06/21/2023 | Site Landscape | REQUIRES RESUBMIT | PROJECT: ALVERNON PARK PATHWAY ACTIVITY NO. TD-DEV-0523-00251 ADDRESS/PARCEL: 701 N LONGFELLOW AV/126-06-198C ZONING: R-1 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section and PAD-12 for landscape, native plants, and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all Landscape/NPPO Review Section comments are addressed. COMMENTS: 1. Ensure that Zoning, Engineering comments, and concerns are addressed prior to landscape section approval. 2. Please include an NPPP or NPPO Waiver form with your resubmittal for the affected areas. 3. Provide the development package case number, TD-DEV-0523-00251, adjacent to the title block on all sheets. 2-06.4.3 4. Please include all required Landscape/Irrigation/Maintenance notes required as part of the submittal. 5. Trees that are located in areas of required landscaping must be a minimum of 15-gallon container size. TSM 5.4 The plan specifies 5 gallon container trees across the site. Please explain. 6. Include spot elevations on the landscape plan for the water harvesting basins. 7. If using d.g at a 2” depth, ensure the rainwater harvesting basins are 8” in depth to account for the d.g. 8. Include a construction detail for trees planted near plazas/sidewalks/concrete paths for the trees planted near the stabilized dg paths. See Detail #402 here: https://www.tucsonaz.gov/tdot/landscape-architects If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988 |
||
| 06/08/2023 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Alvernon Park – Pathway & Drainage Improvements Development Package (1st Review) TD-DEV-0523-00251 TRANSMITTAL DATE: June 8, 2023 DUE DATE: June 29, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is May 24, 2024. CONTENT REQUIREMENTS 1. COMMENT: 2-06.4.3 – Provide the development package case number, TD-DEV-0523-00251, adjacent to the title block on all sheets. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2. COMMENT: 2-06.4.7.A.4 – Revise General Note 4 to show the existing and proposed use to be Parks and Recreation, subject to Use Specific Standards 4.9.13.B & C. If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package & detailed response letter. |
||
| 06/30/2023 | Traffic Engineering Review | REQUIRES RESUBMIT | TD-DEV-0523-00251 (701 N LONGFELLOW AV TUCSON, AZ 85711) Please resubmit revised drawings along with a detailed response letter which states how all comments were addressed. Comments: 1. TSM 7-01.4.3.C.6 Decomposed Granite is not a approved surface for a sidewalk in the ROW. A Technical Standards Modification Request (TSMR) will be required. You can apply for a TSMR from this permit on TDC Online. 2. The Alvernon Wash which runs through the park has a Q100 flow of 1242 cfs about 0.5 miles downstream. Faffs Riederer Faffs.Riederer@tucsonaz.gov Abbreviations: City of Tucson Code (COTC), Unified Development Code (UDC) Administrative Manual (AM), Technical Standards Manual (TSM), Street Design Guide (SDG), Pima Association of Governments Standard Details (P. A. G. SD), Access Management Guidelines (AMG), Major Streets and Routes Plan (MS&R). |
||
| 05/23/2023 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 05/25/2023 | CDRC Review Coordinator Express | REVIEW COMPLETED | No external reviewers nor added. | ||
| 06/01/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 05/23/2023 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 05/25/2023 | OK to Submit - Landscape Fast | REVIEW COMPLETED | |||
| 05/24/2023 | OK to Submit - Zoning Fast | REVIEW COMPLETED |